⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2037.txt

📁 中、英文RFC文档大全打包下载完全版 .
💻 TXT
📖 第 1 页 / 共 5 页
字号:
    ::= { entityGroups 3 }entityGeneralGroup    OBJECT-GROUP    OBJECTS {              entLastChangeTime            }    STATUS  current    DESCRIPTION            "The collection of objects which are used to represent            general entity information for which a single agent provides            management information."    ::= { entityGroups 4 }entityNotificationsGroup NOTIFICATION-GROUP    NOTIFICATIONS { entConfigChange }    STATUS        current    DESCRIPTION            "The collection of notifications used to indicate Entity MIB            data consistency and general status information."    ::= { entityGroups 5 }ENDMcCloghrie & Bierman        Standards Track                    [Page 25]RFC 2037                 Entity MIB using SMIv2             October 19965.  Usage Examples   The following sections iterate the instance values for two example   networking devices. These examples are kept simple to make them more   understandable. Auxiliary components, such as fans, sensors, empty   slots, and sub-modules are not shown, but might be modeled in real   implementations.5.1.  Router/Bridge   A router containing two slots.  Each slot contains a 3 port   router/bridge module. Each port is represented in the ifTable.  There   are two logical instances of OSPF running and two logical bridges:  Physical entities -- entPhysicalTable:    1 Field-replaceable physical chassis:      entPhysicalDescr.1 ==             "Acme Chassis Model 100"      entPhysicalVendorType.1  ==       acmeProducts.chassisTypes.1      entPhysicalContainedIn.1 ==       0      entPhysicalClass.1 ==             chassis(3)      entPhysicalParentRelPos.1 ==      0      entPhysicalName.1 ==              '100-A'    2 slots within the chassis:      entPhysicalDescr.2 ==             "Acme Chassis Slot Type AA"      entPhysicalVendorType.2  ==       acmeProducts.slotTypes.1      entPhysicalContainedIn.2 ==       1      entPhysicalClass.2 ==             container(5)      entPhysicalParentRelPos.2 ==      1      entPhysicalName.2 ==              'S1'      entPhysicalDescr.3 ==             "Acme Chassis Slot Type AA"      entPhysicalVendorType.3  ==       acmeProducts.slotTypes.1      entPhysicalContainedIn.3 ==       1      entPhysicalClass.3 ==             container(5)      entPhysicalParentRelPos.3 ==      2      entPhysicalName.3 ==              'S2'    2 Field-replaceable modules:    Slot 1 contains a module with 3 ports:      entPhysicalDescr.4 ==             "Acme Router-100"      entPhysicalVendorType.4  ==       acmeProducts.moduleTypes.14      entPhysicalContainedIn.4 ==       2      entPhysicalClass.4 ==             module(9)      entPhysicalParentRelPos.4 ==      1      entPhysicalName.4 ==              'M1'      entPhysicalDescr.5 ==             "Acme Ethernet-100 Port Rev G"McCloghrie & Bierman        Standards Track                    [Page 26]RFC 2037                 Entity MIB using SMIv2             October 1996      entPhysicalVendorType.5  ==       acmeProducts.portTypes.2      entPhysicalContainedIn.5 ==       4      entPhysicalClass.5 ==             port(10)      entPhysicalParentRelPos.5 ==      1      entPhysicalName.5 ==              'P1'      entPhysicalDescr.6 ==             "Acme Ethernet-100 Port Rev G"      entPhysicalVendorType.6  ==       acmeProducts.portTypes.2      entPhysicalContainedIn.6 ==       4      entPhysicalClass.6 ==             port(10)      entPhysicalParentRelPos.6 ==      2      entPhysicalName.6 ==              'P2'      entPhysicalDescr.7 ==             "Acme Router-100 F-Port: Rev B"      entPhysicalVendorType.7  ==       acmeProducts.portTypes.3      entPhysicalContainedIn.7 ==       4      entPhysicalClass.7 ==             port(10)      entPhysicalParentRelPos.7 ==      3      entPhysicalName.7 ==              'P3'   Slot 2 contains another 3-port module:      entPhysicalDescr.8 ==             "Acme Router-100 Comm Module: Rev C"      entPhysicalVendorType.8  ==       acmeProducts.moduleTypes.15      entPhysicalContainedIn.8 ==       3      entPhysicalClass.8 ==             module(9)      entPhysicalParentRelPos.8 ==      1      entPhysicalName.8 ==              'M2'      entPhysicalDescr.9 ==             "Acme Fddi-100 Port Rev CC"      entPhysicalVendorType.9 ==        acmeProducts.portTypes.5      entPhysicalContainedIn.9 ==       8      entPhysicalClass.9 ==             port(10)      entPhysicalParentRelPos.9 ==      1      entPhysicalName.9 ==              'FDDI Primary'      entPhysicalDescr.10 ==            "Acme Ethernet-100 Port Rev G"      entPhysicalVendorType.10 ==       acmeProducts.portTypes.2      entPhysicalContainedIn.10 ==      8      entPhysicalClass.10 ==            port(10)      entPhysicalParentRelPos.10 ==     2      entPhysicalName.10 ==             'Ethernet A'      entPhysicalDescr.11 ==            "Acme Ethernet-100 Port Rev G"      entPhysicalVendorType.11 ==       acmeProducts.portTypes.2      entPhysicalContainedIn.11 ==      8      entPhysicalClass.11 ==            port(10)      entPhysicalParentRelPos.11 ==     3      entPhysicalName.11 ==             'Ethernet B'McCloghrie & Bierman        Standards Track                    [Page 27]RFC 2037                 Entity MIB using SMIv2             October 1996   Logical entities -- entLogicalTable    2 OSPF instances:      entLogicalDescr.1 ==            "Acme OSPF v1.1"      entLogicalType.1 ==             ospf      entLogicalCommunity.1 ==        "public-ospf1"      entLogicalTAddress.1 ==         124.125.126.127:161      entLogicalTDomain.1 ==          snmpUDPDomain      entLogicalDescr.2 ==            "Acme OSPF v1.1"      entLogicalType.2 ==             ospf      entLogicalCommunity.2 ==        "public-ospf2"      entLogicalTAddress.2 ==         124.125.126.127:161      entLogicalTDomain.2 ==          snmpUDPDomain    2 logical bridges:      entLogicalDescr.3 ==            "Acme Bridge v2.1.1"      entLogicalType.3  ==            dod1dBridge      entLogicalCommunity.3 ==        "public-bridge1"      entLogicalTAddress.3 ==         124.125.126.127:161      entLogicalTDomain.3 ==          snmpUDPDomain      entLogicalDescr.4 ==            "Acme Bridge v2.1.1"      entLogicalType.4 ==             dod1dBridge      entLogicalCommunity.4 ==        "public-bridge2"      entLogicalTAddress.4 ==         124.125.126.127:161      entLogicalTDomain.4 ==          snmpUDPDomainLogical to Physical Mappings:  1st OSPF instance: uses module 1-port 1      entLPPhysicalIndex.1.5 ==         5  2nd OSPF instance: uses module 2-port 1      entLPPhysicalIndex.2.9 ==         9  1st bridge group: uses module 1, all ports  [ed. -- Note that these mappings are included in the table since  another logical entity (1st OSPF) utilizes one of the  ports. If this were not the case, then a single mapping  to the module (e.g. entLPPhysicalIndex.3.4) would be  present instead. ]      entLPPhysicalIndex.3.5 ==         5      entLPPhysicalIndex.3.6 ==         6      entLPPhysicalIndex.3.7 ==         7  2nd bridge group: uses module 2, all ports      entLPPhysicalIndex.4.9  ==        9      entLPPhysicalIndex.4.10 ==        10McCloghrie & Bierman        Standards Track                    [Page 28]RFC 2037                 Entity MIB using SMIv2             October 1996      entLPPhysicalIndex.4.11 ==        11Physical to Logical to MIB Alias Mappings -- entAliasMappingTable:  Example 1: ifIndex values are global to all logical entities      entAliasMappingIdentifier.5.0   ==        ifIndex.1      entAliasMappingIdentifier.6.0   ==        ifIndex.2      entAliasMappingIdentifier.7.0   ==        ifIndex.3      entAliasMappingIdentifier.9.0   ==        ifIndex.4      entAliasMappingIdentifier.10.0  ==        ifIndex.5      entAliasMappingIdentifier.11.0  ==        ifIndex.6  Example 2: ifIndex values are not shared by all logical entities      entAliasMappingIdentifier.5.0   ==        ifIndex.1      entAliasMappingIdentifier.5.3   ==        ifIndex.101      entAliasMappingIdentifier.6.0   ==        ifIndex.2      entAliasMappingIdentifier.6.3   ==        ifIndex.102      entAliasMappingIdentifier.7.0   ==        ifIndex.3      entAliasMappingIdentifier.7.3   ==        ifIndex.103      entAliasMappingIdentifier.9.0   ==        ifIndex.4      entAliasMappingIdentifier.9.3   ==        ifIndex.204      entAliasMappingIdentifier.10.0  ==        ifIndex.5      entAliasMappingIdentifier.10.3  ==        ifIndex.205      entAliasMappingIdentifier.11.0  ==        ifIndex.6      entAliasMappingIdentifier.11.3  ==        ifIndex.206Physical Containment Tree -- entPhysicalContainsTable  chassis has two containers:      entPhysicalChildIndex.1.2 = 2      entPhysicalChildIndex.1.3 = 3  container 1 has a module:      entPhysicalChildIndex.2.4 = 4  container 2 has a module:      entPhysicalChildIndex.3.8 = 8  module 1 has 3 ports:      entPhysicalChildIndex.4.5 = 5      entPhysicalChildIndex.4.6 = 6      entPhysicalChildIndex.4.7 = 7  module 2 has 3 ports:      entPhysicalChildIndex.8.9 = 9      entPhysicalChildIndex.8.10 = 10      entPhysicalChildIndex.1.11 = 11McCloghrie & Bierman        Standards Track                    [Page 29]RFC 2037                 Entity MIB using SMIv2             October 19965.2.  Repeaters   A 3-slot Hub with 2 backplane ethernet segments.  Slot three is   empty, and the remaining slots contain ethernet repeater modules.   [ed. -- Note that a replacement for the current Repeater MIB (RFC   1516) is likely to emerge soon, and it will no longer be necessary to   access repeater MIB data in different naming scopes.]Physical entities -- entPhysicalTable:   1 Field-replaceable physical chassis:      entPhysicalDescr.1 ==          "Acme Chassis Model 110"      entPhysicalVendorType.1 ==     acmeProducts.chassisTypes.2      entPhysicalContainedIn.1 ==    0      entPhysicalClass.1 ==          chassis(3)      entPhysicalParentRelPos.1 ==   0      entPhysicalName.1 ==           '110-B'   2 Chassis Ethernet Backplanes:      entPhysicalDescr.2 ==          "Acme Ethernet Backplane Type A"      entPhysicalVendorType.2 ==     acmeProducts.backplaneTypes.1      entPhysicalContainedIn.2 ==    1      entPhysicalClass.2 ==          backplane(4)      entPhysicalParentRelPos.2 ==   1      entPhysicalName.2 ==           'B1'      entPhysicalDescr.3 ==          "Acme Ethernet Backplane Type A"      entPhysicalVendorType.3  ==    acmeProducts.backplaneTypes.1      entPhysicalContainedIn.3 ==    1      entPhysicalClass.3 ==          backplane(4)      entPhysicalParentRelPos.3 ==   2      entPhysicalName.3 ==           'B2'   3 slots within the chassis:      entPhysicalDescr.4 ==          "Acme Hub Slot Type RB"      entPhysicalVendorType.4  ==    acmeProducts.slotTypes.5      entPhysicalContainedIn.4 ==    1      entPhysicalClass.4 ==          container(5)      entPhysicalParentRelPos.4 ==   1      entPhysicalName.4 ==           'Slot 1'      entPhysicalDescr.5 ==          "Acme Hub Slot Type RB"      entPhysicalVendorType.5  ==    acmeProducts.slotTypes.5      entPhysicalContainedIn.5 ==    1      entPhysicalClass.5 ==          container(5)      entPhysicalParentRelPos.5 ==   2      entPhysicalName.5 ==           'Slot 2'      entPhysicalDescr.6 ==          "Acme Hub Slot Type RB"McCloghrie & Bierman        Standards Track                    [Page 30]RFC 2037                 Entity MIB using SMIv2             October 1996      entPhysicalVendorType.6  ==    acmeProducts.slotTypes.5      entPhysicalContainedIn.6 ==    1      entPhysicalClass.6 ==          container(5)      entPhysicalParentRelPos.6 ==   3      entPhysicalName.6 ==           'Slot 3'   Slot 1 contains a plug-in module with 4 10-BaseT ports:      entPhysicalDescr.7  ==         "Acme 10Base-T Module 114 Rev A"      entPhysicalVendorType.7   ==   acmeProducts.moduleTypes.32      entPhysicalContainedIn.7  ==   4      ent

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -