📄 rfc2670.txt
字号:
docsIfDownChannelFrequency OBJECT-TYPE SYNTAX Integer32 (0..1000000000) UNITS "hertz" MAX-ACCESS read-write STATUS current DESCRIPTION "The center of the downstream frequency associated with this channel. This object will return the current tuner frequency. If a CMTS provides IF output, this object will return 0, unless this CMTS is in control of the final downstream RF frequency. See the associatedSt. Johns Standard [Page 20]RFC 2670 DOCSIS RF Interface MIB August 1999 compliance object for a description of valid frequencies that may be written to this object." REFERENCE "DOCSIS Radio Frequency Interface Specification, Section 4.3.3." ::= { docsIfDownstreamChannelEntry 2 }docsIfDownChannelWidth OBJECT-TYPE SYNTAX Integer32 (0..16000000) UNITS "hertz" MAX-ACCESS read-write STATUS current DESCRIPTION "The bandwidth of this downstream channel. Most implementations are expected to support a channel width of 6 MHz (North America) and/or 8 MHz (Europe). See the associated compliance object for a description of the valid channel widths for this object." REFERENCE "DOCSIS Radio Frequency Interface Specification, Table 4-12 and Table 4-13." ::= { docsIfDownstreamChannelEntry 3 }docsIfDownChannelModulation OBJECT-TYPE SYNTAX INTEGER { unknown(1), other(2), qam64(3), qam256(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "The modulation type associated with this downstream channel. If the interface is down, this object either returns the configured value (CMTS), the most current value (CM), or the value of unknown(1). See the associated conformance object for write conditions and limitations. See the reference for specifics on the modulation profiles implied by qam64 and qam256." REFERENCE "DOCSIS Radio Frequency Interface Specification, Section 3.6.2." ::= { docsIfDownstreamChannelEntry 4 }docsIfDownChannelInterleave OBJECT-TYPE SYNTAX INTEGER { unknown(1),St. Johns Standard [Page 21]RFC 2670 DOCSIS RF Interface MIB August 1999 other(2), taps8Increment16(3), taps16Increment8(4), taps32Increment4(5), taps64Increment2(6), taps128Increment1(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "The Forward Error Correction (FEC) interleaving used for this downstream channel. Values are defined as follows: taps8Increment16(3): protection 5.9/4.1 usec, latency .22/.15 msec taps16Increment8(4): protection 12/8.2 usec, latency .48/.33 msec taps32Increment4(5): protection 24/16 usec, latency .98/.68 msec taps64Increment2(6): protection 47/33 usec, latency 2/1.4 msec taps128Increment1(7): protection 95/66 usec, latency 4/2.8 msec If the interface is down, this object either returns the configured value (CMTS), the most current value (CM), or the value of unknown(1). The value of other(2) is returned if the interleave is known but not defined in the above list. See the associated conformance object for write conditions and limitations. See the reference for the FEC configuration described by the setting of this object." REFERENCE "DOCSIS Radio Frequency Interface Specification, Section 4.3.2." ::= { docsIfDownstreamChannelEntry 5 }docsIfDownChannelPower OBJECT-TYPE SYNTAX TenthdBmV UNITS "dBmV" MAX-ACCESS read-write STATUS current DESCRIPTION "At the CMTS, the operational transmit power. At the CM, the received power level. May be set to zero at the CM if power level measurement is not supported. If the interface is down, this object either returns the configured value (CMTS), the most current value (CM) or the value of 0. See the associated conformance objectSt. Johns Standard [Page 22]RFC 2670 DOCSIS RF Interface MIB August 1999 for write conditions and limitations. See the reference for recommended and required power levels." REFERENCE "DOCSIS Radio Frequency Interface Specification, Table 4-12 and Table 4-13." ::= { docsIfDownstreamChannelEntry 6 }---- The following table is implemented on both the CM and the CMTS.-- For the CM, only attached channels appear in the table. For the-- CM, this table is read only as well.--docsIfUpstreamChannelTable OBJECT-TYPE SYNTAX SEQUENCE OF DocsIfUpstreamChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table describes the attributes of attached upstream channels (frequency bands)." ::= { docsIfBaseObjects 2 }docsIfUpstreamChannelEntry OBJECT-TYPE SYNTAX DocsIfUpstreamChannelEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "List of attributes for a single upstream channel. An entry in this table exists for each ifEntry with an ifType of docsCableUpstream(129)." INDEX { ifIndex } ::= { docsIfUpstreamChannelTable 1 }DocsIfUpstreamChannelEntry ::= SEQUENCE { docsIfUpChannelId Integer32, docsIfUpChannelFrequency Integer32, docsIfUpChannelWidth Integer32, docsIfUpChannelModulationProfile Unsigned32, docsIfUpChannelSlotSize Unsigned32, docsIfUpChannelTxTimingOffset Unsigned32, docsIfUpChannelRangingBackoffStart Integer32, docsIfUpChannelRangingBackoffEnd Integer32, docsIfUpChannelTxBackoffStart Integer32, docsIfUpChannelTxBackoffEnd Integer32 }docsIfUpChannelId OBJECT-TYPE SYNTAX Integer32 (0..255)St. Johns Standard [Page 23]RFC 2670 DOCSIS RF Interface MIB August 1999 MAX-ACCESS read-only STATUS current DESCRIPTION "The CMTS identification of the upstream channel." ::= { docsIfUpstreamChannelEntry 1 }docsIfUpChannelFrequency OBJECT-TYPE SYNTAX Integer32 (0..1000000000) UNITS "hertz" MAX-ACCESS read-write STATUS current DESCRIPTION "The center of the frequency band associated with this upstream channel. This object returns 0 if the frequency is undefined or unknown. Minimum permitted upstream frequency is 5,000,000 Hz for current technology. See the associated conformance object for write conditions and limitations." REFERENCE "DOCSIS Radio Frequency Interface Specification, Table 2-2." ::= { docsIfUpstreamChannelEntry 2 }docsIfUpChannelWidth OBJECT-TYPE SYNTAX Integer32 (0..20000000) UNITS "hertz" MAX-ACCESS read-write STATUS current DESCRIPTION "The bandwidth of this upstream channel. This object returns 0 if the channel width is undefined or unknown. Minimum permitted channel width is 200,000 Hz currently. See the associated conformance object for write conditions and limitations." REFERENCE "DOCSIS Radio Frequency Interface Specification, Table 4-3." ::= { docsIfUpstreamChannelEntry 3 }docsIfUpChannelModulationProfile OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "An entry identical to the docsIfModIndex in the docsIfCmtsModulationTable that describes this channel. This channel is further instantiated there by a grouping of interval usage codes which together fully describe theSt. Johns Standard [Page 24]RFC 2670 DOCSIS RF Interface MIB August 1999 channel modulation. This object returns 0 if the docsIfCmtsModulationTable entry does not exist or docsIfCmtsModulationTable is empty. See the associated conformance object for write conditions and limitations." ::= { docsIfUpstreamChannelEntry 4 }docsIfUpChannelSlotSize OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of 6.25 microsecond ticks in each upstream mini- slot. Returns zero if the value is undefined or unknown. See the associated conformance object for write conditions and limitations." REFERENCE "DOCSIS Radio Frequency Interface Specification, Section 6.1.2.4." ::= { docsIfUpstreamChannelEntry 5 }docsIfUpChannelTxTimingOffset OBJECT-TYPE SYNTAX Unsigned32 MAX-ACCESS read-only STATUS current DESCRIPTION "A measure of the current round trip time at the CM, or the maximum round trip time seen by the CMTS. Used for timing of CM upstream transmissions to ensure synchronized arrivals at the CMTS. Units are in terms of (6.25 microseconds/64)." REFERENCE "DOCSIS Radio Frequency Interface Specification, Section 6.5." ::= { docsIfUpstreamChannelEntry 6 }docsIfUpChannelRangingBackoffStart OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-write STATUS current DESCRIPTION "The initial random backoff window to use when retrying Ranging Requests. Expressed as a power of 2. A value of 16 at the CMTS indicates that a proprietary adaptive retry mechanism is to be used. See the associated conformance object for write conditions and limitations." REFERENCE "DOCSIS Radio Frequency Interface Specification,St. Johns Standard [Page 25]RFC 2670 DOCSIS RF Interface MIB August 1999 Section 6.4.4." ::= { docsIfUpstreamChannelEntry 7 }docsIfUpChannelRangingBackoffEnd OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-write STATUS current DESCRIPTION "The final random backoff window to use when retrying Ranging Requests. Expressed as a power of 2. A value of 16 at the CMTS indicates that a proprietary adaptive retry mechanism is to be used. See the associated conformance object for write conditions and limitations." REFERENCE "DOCSIS Radio Frequency Interface Specification, Section 6.4.4." ::= { docsIfUpstreamChannelEntry 8 }docsIfUpChannelTxBackoffStart OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-write STATUS current DESCRIPTION "The initial random backoff window to use when retrying transmissions. Expressed as a power of 2. A value of 16 at the CMTS indicates that a proprietary adaptive retry mechanism is to be used. See the associated conformance object for write conditions and limitations." REFERENCE "DOCSIS Radio Frequency Interface Specification, Section 6.4.4." ::= { docsIfUpstreamChannelEntry 9 }docsIfUpChannelTxBackoffEnd OBJECT-TYPE SYNTAX Integer32 (0..16) MAX-ACCESS read-write STATUS current DESCRIPTION "The final random backoff window to use when retrying transmissions. Expressed as a power of 2. A value of 16 at the CMTS indicates that a proprietary adaptive retry mechanism is to be used. See the associated conformance object for write conditions and limitations." REFERENCE "DOCSIS Radio Frequency Interface Specification, Section 6.4.4." ::= { docsIfUpstreamChannelEntry 10 }St. Johns Standard [Page 26]RFC 2670 DOCSIS RF Interface MIB August 1999-- The following table describes the attributes of each class of-- service. The entries in this table are referenced from the-- docsIfServiceEntries. They exist as a separate table in order to-- reduce redundant information in docsIfServiceTable.---- This table is implemented at both the CM and the CMTS.-- The CM need only maintain entries for the classes of service-- referenced by its docsIfServiceTable.--docsIfQosProfileTable OBJECT-TYPE SYNTAX SEQUENCE OF DocsIfQosProfileEntry MAX-ACCESS not-accessible STATUS current
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -