📄 form1.frm
字号:
VERSION 5.00
Begin VB.Form Form1
BorderStyle = 1 'Fixed Single
Caption = "PING程序"
ClientHeight = 3765
ClientLeft = 3840
ClientTop = 4035
ClientWidth = 6300
BeginProperty Font
Name = "Arial"
Size = 8.25
Charset = 0
Weight = 400
Underline = 0 'False
Italic = 0 'False
Strikethrough = 0 'False
EndProperty
Icon = "Form1.frx":0000
LinkTopic = "Form1"
MaxButton = 0 'False
MinButton = 0 'False
PaletteMode = 1 'UseZOrder
ScaleHeight = 3765
ScaleWidth = 6300
Begin VB.TextBox Text3
BeginProperty Font
Name = "Terminal"
Size = 9
Charset = 255
Weight = 400
Underline = 0 'False
Italic = 0 'False
Strikethrough = 0 'False
EndProperty
Height = 2490
Left = 75
MultiLine = -1 'True
ScrollBars = 3 'Both
TabIndex = 5
Top = 1200
Width = 6045
End
Begin VB.TextBox Text1
Alignment = 2 'Center
Height = 315
Left = 1890
TabIndex = 0
Text = "www.sohu.com"
Top = 195
Width = 1965
End
Begin VB.CommandButton Command1
Caption = "&Ping"
BeginProperty Font
Name = "MS Sans Serif"
Size = 8.25
Charset = 0
Weight = 400
Underline = 0 'False
Italic = 0 'False
Strikethrough = 0 'False
EndProperty
Height = 390
Left = 4440
TabIndex = 1
Top = 360
Width = 765
End
Begin VB.Label Label3
Alignment = 2 'Center
BackColor = &H00FFFFFF&
BorderStyle = 1 'Fixed Single
Height = 315
Left = 1890
TabIndex = 4
Top = 570
Width = 1965
End
Begin VB.Label Label2
Alignment = 1 'Right Justify
Caption = "IP地址:"
Height = 255
Left = 990
TabIndex = 3
Top = 645
Width = 870
End
Begin VB.Label Label1
Alignment = 1 'Right Justify
Caption = "主机名:"
Height = 255
Left = 915
TabIndex = 2
Top = 270
Width = 975
End
End
Attribute VB_Name = "Form1"
Attribute VB_GlobalNameSpace = False
Attribute VB_Creatable = False
Attribute VB_PredeclaredId = True
Attribute VB_Exposed = False
' WSock32 变量
Dim iReturn As Long, sLowByte As String, sHighByte As String
Dim sMsg As String, HostLen As Long, Host As String
Dim Hostent As Hostent, PointerToPointer As Long, ListAddress As Long
Dim WSAdata As WSAdata, DotA As Long, DotAddr As String, ListAddr As Long
Dim MaxUDP As Long, MaxSockets As Long, i As Integer
Dim Description As String, Status As String
' ICMP 变量
Dim bReturn As Boolean, hIP As Long
Dim szBuffer As String
Dim Addr As Long
Dim RCode As String
Dim RespondingHost As String
' TRACERT 变量
Dim TraceRT As Boolean
Dim TTL As Integer
' WSock32 常数
Const WS_VERSION_MAJOR = &H101 \ &H100 And &HFF&
Const WS_VERSION_MINOR = &H101 And &HFF&
Const MIN_SOCKETS_REQD = 0
'将状态码翻译成相关的说明
Sub GetRCode()
If pIPe.Status = 0 Then RCode = "Success"
If pIPe.Status = 11001 Then RCode = "Buffer too Small"
If pIPe.Status = 11002 Then RCode = "Dest Network Not Reachable"
If pIPe.Status = 11003 Then RCode = "Dest Host Not Reachable"
If pIPe.Status = 11004 Then RCode = "Dest Protocol Not Reachable"
If pIPe.Status = 11005 Then RCode = "Dest Port Not Reachable"
If pIPe.Status = 11006 Then RCode = "No Resources Available"
If pIPe.Status = 11007 Then RCode = "Bad Option"
If pIPe.Status = 11008 Then RCode = "Hardware Error"
If pIPe.Status = 11009 Then RCode = "Packet too Big"
If pIPe.Status = 11010 Then RCode = "Rqst Timed Out"
If pIPe.Status = 11011 Then RCode = "Bad Request"
If pIPe.Status = 11012 Then RCode = "Bad Route"
If pIPe.Status = 11013 Then RCode = "TTL Exprd in Transit"
If pIPe.Status = 11014 Then RCode = "TTL Exprd Reassemb"
If pIPe.Status = 11015 Then RCode = "Parameter Problem"
If pIPe.Status = 11016 Then RCode = "Source Quench"
If pIPe.Status = 11017 Then RCode = "Option too Big"
If pIPe.Status = 11018 Then RCode = " Bad Destination"
If pIPe.Status = 11019 Then RCode = "Address Deleted"
If pIPe.Status = 11020 Then RCode = "Spec MTU Change"
If pIPe.Status = 11021 Then RCode = "MTU Change"
If pIPe.Status = 11022 Then RCode = "Unload"
If pIPe.Status = 11050 Then RCode = "General Failure"
RCode = RCode + " (" + CStr(pIPe.Status) + ")"
DoEvents
If TraceRT = False Then
If pIPe.Status = 0 Then
Text3.Text = Text3.Text + " Reply from " + RespondingHost + ": Bytes = " + Trim$(CStr(pIPe.DataSize)) + " RTT = " + Trim$(CStr(pIPe.RoundTripTime)) + "ms TTL = " + Trim$(CStr(pIPe.Options.TTL)) + Chr$(13) + Chr$(10)
Else
Text3.Text = Text3.Text + " Reply from " + RespondingHost + ": " + RCode + Chr$(13) + Chr$(10)
End If
Else
If TTL - 1 < 10 Then Text3.Text = Text3.Text + " Hop # 0" + CStr(TTL - 1) Else Text3.Text = Text3.Text + " Hop # " + CStr(TTL - 1)
Text3.Text = Text3.Text + " " + RespondingHost + Chr$(13) + Chr$(10)
End If
End Sub
Sub vbGetHostByName()
Dim szString As String
Host = Trim$(Text1.Text) ' 获得主机地址
szString = String(64, &H0)
Host = Host + Right$(szString, 64 - Len(Host))
If gethostbyname(Host) = SOCKET_ERROR Then ' WSock32错误
sMsg = "Winsock Error" & Str$(WSAGetLastError())
MsgBox sMsg, vbOKOnly, "VB4032-ICMPEcho"
Else
PointerToPointer = gethostbyname(Host) ' 获得winsock结构地址指针Get the pointer to the address of the winsock hostent structure
CopyMemory Hostent.h_name, ByVal _
PointerToPointer, Len(Hostent) ' 将Winsock结构复制成VB结构
ListAddress = Hostent.h_addr_list ' 获得地址列表
CopyMemory ListAddr, ByVal ListAddress, 4 ' 复制内存
CopyMemory IPLong, ByVal ListAddr, 4 ' 获得Address List的第一个入口
CopyMemory Addr, ByVal ListAddr, 4
Label3.Caption = Trim$(CStr(Asc(IPLong.Byte4)) + "." + CStr(Asc(IPLong.Byte3)) _
+ "." + CStr(Asc(IPLong.Byte2)) + "." + CStr(Asc(IPLong.Byte1)))
End If
End Sub
Sub vbGetHostName()
Host = String(64, &H0) ' 获得一个空字符串
If gethostname(Host, HostLen) = SOCKET_ERROR Then '
sMsg = "WSock32 Error" & Str$(WSAGetLastError()) ' 如果有WSOCK32错误
MsgBox sMsg, vbOKOnly, "VB4032-ICMPEcho"
Else
Host = Left$(Trim$(Host), Len(Trim$(Host)) - 1) ' 去掉结果种的空格
Text1.Text = Host ' 显示主机名
End If
End Sub
Sub vbIcmpSendEcho()
Dim NbrOfPkts As Integer
szBuffer = "abcdefghijklmnopqrstuvwabcdefghijklmnopqrstuvwabcdefghijklmnopqrstuvwabcdefghijklmnopqrstuvwabcdefghijklmnopqrstuvwabcdefghijklm"
'数据包大小
szBuffer = Left$(szBuffer, 32)
'包发送次数
For NbrOfPkts = 1 To 5
DoEvents
bReturn = IcmpSendEcho(hIP, Addr, szBuffer, Len(szBuffer), pIPo, pIPe, Len(pIPe) + 8, 2700)
If bReturn Then
RespondingHost = CStr(pIPe.Address(0)) + "." + CStr(pIPe.Address(1)) + "." + CStr(pIPe.Address(2)) + "." + CStr(pIPe.Address(3))
GetRCode
Else ' ICMP超时
'
If TraceRT Then
TTL = TTL - 1
Else
Text3.Text = Text3.Text + "ICMP Request Timeout" + Chr$(13) + Chr$(10)
End If
End If
Next NbrOfPkts
End Sub
Sub vbWSAStartup()
' 初始化Winsock
iReturn = WSAStartup(&H101, WSAdata)
If iReturn <> 0 Then
MsgBox "WSock32.dll is not responding!", vbOKOnly, "VB4032-ICMPEcho"
End If
If LoByte(WSAdata.wVersion) < WS_VERSION_MAJOR Or (LoByte(WSAdata.wVersion) = WS_VERSION_MAJOR And HiByte(WSAdata.wVersion) < WS_VERSION_MINOR) Then
sHighByte = Trim$(Str$(HiByte(WSAdata.wVersion)))
sLowByte = Trim$(Str$(LoByte(WSAdata.wVersion)))
sMsg = "WinSock Version " & sLowByte & "." & sHighByte
sMsg = sMsg & " is not supported "
MsgBox sMsg, vbOKOnly, "VB4032-ICMPEcho"
End
End If
If WSAdata.iMaxSockets < MIN_SOCKETS_REQD Then
sMsg = "This application requires a minimum of "
sMsg = sMsg & Trim$(Str$(MIN_SOCKETS_REQD)) & " supported sockets."
MsgBox sMsg, vbOKOnly, "VB4032-ICMPEcho"
End
End If
MaxSockets = WSAdata.iMaxSockets
'WSAdata.iMaxSockets是一个无符号Short类型,必须转化成为无符号Long型
If MaxSockets < 0 Then
MaxSockets = 65536 + MaxSockets
End If
MaxUDP = WSAdata.iMaxUdpDg
If MaxUDP < 0 Then
MaxUDP = 65536 + MaxUDP
End If
' 处理Winsock描述信息
Description = ""
For i = 0 To WSADESCRIPTION_LEN
If WSAdata.szDescription(i) = 0 Then Exit For
Description = Description + Chr$(WSAdata.szDescription(i))
Next i
' 处理winsock状态信息
Status = ""
For i = 0 To WSASYS_STATUS_LEN
If WSAdata.szSystemStatus(i) = 0 Then Exit For
Status = Status + Chr$(WSAdata.szSystemStatus(i))
Next i
End Sub
Function HiByte(ByVal wParam As Integer)
HiByte = wParam \ &H100 And &HFF&
End Function
Function LoByte(ByVal wParam As Integer)
LoByte = wParam And &HFF&
End Function
Sub vbWSACleanup()
' 终止winsock
iReturn = WSACleanup()
If iReturn <> 0 Then
sMsg = "WSock32 Error - " & Trim$(Str$(iReturn)) & " occurred in Cleanup"
MsgBox sMsg, vbOKOnly, "VB4032-ICMPEcho"
End
End If
End Sub
Sub vbIcmpCloseHandle()
bReturn = IcmpCloseHandle(hIP)
If bReturn = False Then
MsgBox "ICMP Closed with Error", vbOKOnly, "VB4032-ICMPEcho"
End If
End Sub
Sub vbIcmpCreateFile()
hIP = IcmpCreateFile()
If hIP = 0 Then
MsgBox "Unable to Create File Handle", vbOKOnly, "VBPing32"
End If
End Sub
Private Sub Command1_Click()
vbWSAStartup ' 初始化winsock
If Len(Text1.Text) = 0 Then
vbGetHostName
End If
If Text1.Text = "" Then
MsgBox "No Hostname Specified!", vbOKOnly, "VB4032-ICMPEcho"
vbWSACleanup
Exit Sub
End If
vbGetHostByName ' 获得IP地址
vbIcmpCreateFile ' 获得ICMP 句柄
'设置TTL为255
pIPo.TTL = 255
vbIcmpSendEcho ' 发送ICMP回显请求
vbIcmpCloseHandle ' 关闭ICMP 句柄
vbWSACleanup ' 关闭winsock
End Sub
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -