⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 connected_to_pwm.mdl

📁 Boost电路调试平台
💻 MDL
📖 第 1 页 / 共 5 页
字号:
      UpperLimit	      "0.5"
      LowerLimit	      "-0.5"
      LinearizeAsGain	      on
      ZeroCross		      on
      SampleTime	      "-1"
      OutMin		      "[]"
      OutMax		      "[]"
      OutDataTypeMode	      "Same as input"
      OutDataType	      "fixdt(1,16,0)"
      OutScaling	      "[]"
      OutDataTypeStr	      "Inherit: Same as input"
      LockScale		      off
      RndMeth		      "Floor"
    }
  }
  AnnotationDefaults {
    HorizontalAlignment	    "center"
    VerticalAlignment	    "middle"
    ForegroundColor	    "black"
    BackgroundColor	    "white"
    DropShadow		    off
    FontName		    "Helvetica"
    FontSize		    10
    FontWeight		    "normal"
    FontAngle		    "normal"
    UseDisplayTextAsClickCallback off
  }
  LineDefaults {
    FontName		    "Helvetica"
    FontSize		    9
    FontWeight		    "normal"
    FontAngle		    "normal"
  }
  System {
    Name		    "connected_to_PWM"
    Location		    [2, 82, 997, 704]
    Open		    on
    ModelBrowserVisibility  off
    ModelBrowserWidth	    200
    ScreenColor		    "white"
    PaperOrientation	    "landscape"
    PaperPositionMode	    "auto"
    PaperType		    "usletter"
    PaperUnits		    "inches"
    TiledPaperMargins	    [0.500000, 0.500000, 0.500000, 0.500000]
    TiledPageScale	    1
    ShowPageBoundaries	    off
    ZoomFactor		    "100"
    ReportName		    "simulink-default.rpt"
    Block {
      BlockType		      Reference
      Name		      "C"
      Ports		      [0, 0, 0, 0, 0, 1, 1]
      Position		      [534, 430, 586, 485]
      Orientation	      "down"
      NamePlacement	      "alternate"
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      FontName		      "Verdana"
      FontSize		      11
      SourceBlock	      "powerlib/Elements/Parallel RLC Branch"
      SourceType	      "Parallel RLC Branch"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
      RConnTagsString	      "__new0"
      BranchType	      "C"
      Resistance	      "1"
      Inductance	      "1e-3"
      SetiL0		      off
      InitialCurrent	      "0"
      Capacitance	      "2200e-6"
      Setx0		      on
      InitialVoltage	      "500"
      Measurements	      "Branch voltage"
    }
    Block {
      BlockType		      Constant
      Name		      "Constant"
      Position		      [730, 385, 760, 415]
      Value		      "500"
      OutDataType	      "sfix(16)"
      OutScaling	      "2^0"
    }
    Block {
      BlockType		      Reference
      Name		      "DC Voltage Source"
      Ports		      [0, 0, 0, 0, 0, 1, 1]
      Position		      [160, 405, 180, 440]
      Orientation	      "up"
      DialogController	      "POWERSYS.PowerSysDialog"
      FontName		      "Verdana"
      FontSize		      11
      SourceBlock	      "powerlib/Electrical\nSources/DC Voltage Source"
      SourceType	      "DC Voltage Source"
      ShowPortLabels	      "FromPortIcon"
      SystemSampleTime	      "-1"
      FunctionWithSeparateData off
      RTWMemSecFuncInitTerm   "Inherit from model"
      RTWMemSecFuncExecute    "Inherit from model"
      RTWMemSecDataConstants  "Inherit from model"
      RTWMemSecDataInternal   "Inherit from model"
      RTWMemSecDataParameters "Inherit from model"
      Amplitude		      "300"
      Measurements	      "None"
    }
    Block {
      BlockType		      Demux
      Name		      "Demux"
      Ports		      [1, 2]
      Position		      [635, 169, 640, 236]
      ShowName		      off
      Outputs		      "2"
      DisplayOption	      "bar"
      Port {
	PortNumber		1
	Name			"Uc"
	RTWStorageClass		"Auto"
	DataLoggingNameMode	"SignalName"
      }
      Port {
	PortNumber		2
	Name			"Il"
	RTWStorageClass		"Auto"
	DataLoggingNameMode	"SignalName"
      }
    }
    Block {
      BlockType		      Reference
      Name		      "Diode"
      Ports		      [0, 1, 0, 0, 0, 1, 1]
      Position		      [410, 310, 465, 350]
      DialogController	      "POWERSYS.PowerSysDialog"
      FontName		      "Verdana"
      FontSize		      11
      SourceBlock	      "powerlib/Power\nElectronics/Diode"
      SourceType	      "Diode"
      ShowPortLabels	      "FromPortIcon"
      SystemSampleTime	      "-1"
      FunctionWithSeparateData off
      RTWMemSecFuncInitTerm   "Inherit from model"
      RTWMemSecFuncExecute    "Inherit from model"
      RTWMemSecDataConstants  "Inherit from model"
      RTWMemSecDataInternal   "Inherit from model"
      RTWMemSecDataParameters "Inherit from model"
      Ron		      "0.0047 "
      Lon		      "0"
      Vf		      "1.8"
      IC		      "0"
      UseSnubber	      off
      Rs		      "500"
      Cs		      "250e-9"
      Measurements	      on
    }
    Block {
      BlockType		      Display
      Name		      "Display"
      Ports		      [1]
      Position		      [820, 80, 910, 110]
      Decimation	      "1"
      Lockdown		      off
    }
    Block {
      BlockType		      Display
      Name		      "Display1"
      Ports		      [1]
      Position		      [930, 585, 1020, 615]
      Decimation	      "1"
      Lockdown		      off
    }
    Block {
      BlockType		      Gain
      Name		      "Gain"
      Position		      [835, 385, 865, 415]
      Gain		      "0.0001"
      ParameterDataTypeMode   "Inherit via internal rule"
      ParameterDataType	      "sfix(16)"
      ParameterScaling	      "2^0"
      ParamDataTypeStr	      "Inherit: Inherit via internal rule"
      OutDataTypeMode	      "Inherit via internal rule"
      OutDataType	      "sfix(16)"
      OutScaling	      "2^0"
      OutDataTypeStr	      "Inherit: Inherit via internal rule"
      SaturateOnIntegerOverflow	off
    }
    Block {
      BlockType		      Reference
      Name		      "L"
      Ports		      [0, 0, 0, 0, 0, 1, 1]
      Position		      [195, 304, 250, 356]
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      FontName		      "Verdana"
      FontSize		      11
      SourceBlock	      "powerlib/Elements/Parallel RLC Branch"
      SourceType	      "Parallel RLC Branch"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
      RConnTagsString	      "__new0"
      BranchType	      "L"
      Resistance	      "1"
      Inductance	      "4e-4"
      SetiL0		      off
      InitialCurrent	      "0"
      Capacitance	      "1e-6"
      Setx0		      off
      InitialVoltage	      "0"
      Measurements	      "Branch voltage and current"
    }
    Block {
      BlockType		      Reference
      Name		      "Mean Value"
      Ports		      [1, 1]
      Position		      [730, 69, 780, 121]
      DialogController	      "POWERSYS.PowerSysDialog"
      FontName		      "Arial"
      SourceBlock	      "powerlib_extras/Measurements/Mean Value"
      SourceType	      "Mean value"
      ShowPortLabels	      "FromPortIcon"
      SystemSampleTime	      "-1"
      FunctionWithSeparateData off
      RTWMemSecFuncInitTerm   "Inherit from model"
      RTWMemSecFuncExecute    "Inherit from model"
      RTWMemSecDataConstants  "Inherit from model"
      RTWMemSecDataInternal   "Inherit from model"
      RTWMemSecDataParameters "Inherit from model"
      Period		      "25e-6"
    }
    Block {
      BlockType		      Reference
      Name		      "Mean Value1"
      Ports		      [1, 1]
      Position		      [860, 574, 910, 626]
      DialogController	      "POWERSYS.PowerSysDialog"
      FontName		      "Arial"
      SourceBlock	      "powerlib_extras/Measurements/Mean Value"
      SourceType	      "Mean value"
      ShowPortLabels	      "FromPortIcon"
      SystemSampleTime	      "-1"
      FunctionWithSeparateData off
      RTWMemSecFuncInitTerm   "Inherit from model"
      RTWMemSecFuncExecute    "Inherit from model"
      RTWMemSecDataConstants  "Inherit from model"
      RTWMemSecDataInternal   "Inherit from model"
      RTWMemSecDataParameters "Inherit from model"
      Period		      "25e-6"
    }
    Block {
      BlockType		      Reference
      Name		      "Mosfet"
      Ports		      [1, 1, 0, 0, 0, 1, 1]
      Position		      [348, 450, 392, 505]
      Orientation	      "down"
      NamePlacement	      "alternate"
      DialogController	      "POWERSYS.PowerSysDialog"
      FontName		      "Verdana"
      FontSize		      11
      SourceBlock	      "powerlib/Power\nElectronics/Mosfet"
      SourceType	      "Mosfet"
      ShowPortLabels	      "FromPortIcon"
      SystemSampleTime	      "-1"
      FunctionWithSeparateData off
      RTWMemSecFuncInitTerm   "Inherit from model"
      RTWMemSecFuncExecute    "Inherit from model"
      RTWMemSecDataConstants  "Inherit from model"
      RTWMemSecDataInternal   "Inherit from model"
      RTWMemSecDataParameters "Inherit from model"
      Ron		      "0.11"
      Lon		      "0"
      Rd		      "0.01"
      Vfd		      "0"
      IC		      "0"
      Rs		      "1e5"
      Cs		      "inf "
      Measurements	      on
    }
    Block {
      BlockType		      Reference
      Name		      "Multimeter"
      Ports		      [0, 1, 0, 0, 0, 1]
      Position		      [480, 186, 520, 224]
      FontName		      "Verdana"
      FontSize		      11
      SourceBlock	      "powerlib/Measurements/Multimeter"
      SourceType	      "MultimeterPSB"
      ShowPortLabels	      "FromPortIcon"
      SystemSampleTime	      "-1"
      FunctionWithSeparateData off
      RTWMemSecFuncInitTerm   "Inherit from model"
      RTWMemSecFuncExecute    "Inherit from model"
      RTWMemSecDataConstants  "Inherit from model"
      RTWMemSecDataInternal   "Inherit from model"
      RTWMemSecDataParameters "Inherit from model"
      PhasorSimulation	      off
      OutputType	      "Complex"
      sel		      "[1 4]"
      L			      "6"
      Gain		      "[1 1]"
      yselected		      "{'Ub: C','Ib: L'};"
      PSBOutputType	      "1"
      PSBequivalent	      "0"
      AxesSetting	      "[0,0.1,-100,100]"
      Display		      "0"
      SavedBlockNames	      "-11"
    }
    Block {
      BlockType		      DiscretePulseGenerator
      Name		      "Pulse\nGenerator"
      Ports		      [0, 1]
      Position		      [260, 148, 305, 182]
      PulseType		      "Time based"
      Period		      "25e-6"
      PulseWidth	      "40"
      Port {
	PortNumber		1
	Name			"Ug"
	RTWStorageClass		"Auto"
	DataLoggingNameMode	"SignalName"
      }
    }
    Block {
      BlockType		      Reference
      Name		      "R1"
      Ports		      [0, 0, 0, 0, 0, 1, 1]
      Position		      [614, 430, 666, 485]
      Orientation	      "down"
      NamePlacement	      "alternate"
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      FontName		      "Verdana"
      FontSize		      11
      SourceBlock	      "powerlib/Elements/Parallel RLC Branch"
      SourceType	      "Parallel RLC Branch"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
      RConnTagsString	      "__new0"
      BranchType	      "R"
      Resistance	      "36"
      Inductance	      "1e-3"
      SetiL0		      off
      InitialCurrent	      "0"
      Capacitance	      "1e-6"
      Setx0		      off
      InitialVoltage	      "0"
      Measurements	      "Branch voltage"
    }
    Block {
      BlockType		      Reference
      Name		      "R2"
      Ports		      [0, 1]
      Position		      [1000, 479, 1025, 491]
      Orientation	      "left"
      NamePlacement	      "alternate"
      ShowName		      off
      SourceBlock	      "simulink/Sources/Repeating\nSequence"
      SourceType	      "Repeating table"
      ShowPortLabels	      "FromPortIcon"
      SystemSampleTime	      "-1"
      FunctionWithSeparateData off
      RTWMemSecFuncInitTerm   "Inherit from model"
      RTWMemSecFuncExecute    "Inherit from model"
      RTWMemSecDataConstants  "Inherit from model"
      RTWMemSecDataInternal   "Inherit from model"
      RTWMemSecDataParameters "Inherit from model"
      rep_seq_t		      "[0 1.25e-5 2.5e-5]"
      rep_seq_y		      "[-0.8 1.2 -0.8]"
    }
    Block {
      BlockType		      Reference
      Name		      "R3"
      Ports		      [0, 0, 0, 0, 0, 1, 1]
      Position		      [354, 365, 406, 420]
      Orientation	      "down"
      NamePlacement	      "alternate"
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      FontName		      "Verdana"
      FontSize		      11
      SourceBlock	      "powerlib/Elements/Parallel RLC Branch"
      SourceType	      "Parallel RLC Branch"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
      RConnTagsString	      "__new0"
      BranchType	      "R"
      Resistance	      "0.001"
      Inductance	      "1e-3"
      SetiL0		      off
      InitialCurrent	      "0"
      Capacitance	      "1e-6"
      Setx0		      off
      InitialVoltage	      "0"
      Measurements	      "Branch current"
    }
    Block {
      BlockType		      Reference
      Name		      "R4"
      Ports		      [0, 0, 0, 0, 0, 1, 1]
      Position		      [280, 304, 335, 356]
      Orientation	      "left"
      NamePlacement	      "alternate"
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      FontName		      "Verdana"
      FontSize		      11
      SourceBlock	      "powerlib/Elements/Parallel RLC Branch"
      SourceType	      "Parallel RLC Branch"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
      RConnTagsString	      "__new0"
      BranchType	      "R"
      Resistance	      "2"
      Inductance	      "1e-3"
      SetiL0		      off

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -