📄 power_compensated.mdl

📁 功率补偿仿真图设计
💻 MDL
📖 第 1 页 / 共 5 页
字号:
      Orientation	      "up"
      NamePlacement	      "alternate"
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      SourceBlock	      "powerlib/Elements/Series RLC Load"
      SourceType	      "Series RLC Load"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
      RConnTagsString	      "__new0"
      NominalVoltage	      "735000/sqrt(3)"
      NominalFrequency	      "60"
      ActivePower	      "110e6/300"
      InductivePower	      "110e6"
      CapacitivePower	      "0"
      Setx0		      off
      InitialVoltage	      "0"
      SetiL0		      off
      InitialCurrent	      "0"
      Measurements	      "None"
    }
    Block {
      BlockType		      Reference
      Name		      "110 Mvar2"
      Ports		      [0, 0, 0, 0, 0, 1, 1]
      Position		      [480, 185, 510, 245]
      Orientation	      "up"
      NamePlacement	      "alternate"
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      SourceBlock	      "powerlib/Elements/Series RLC Load"
      SourceType	      "Series RLC Load"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
      RConnTagsString	      "__new0"
      NominalVoltage	      "735000/sqrt(3)"
      NominalFrequency	      "60"
      ActivePower	      "110e6/300"
      InductivePower	      "110e6"
      CapacitivePower	      "0"
      Setx0		      off
      InitialVoltage	      "0"
      SetiL0		      off
      InitialCurrent	      "0"
      Measurements	      "None"
    }
    Block {
      BlockType		      Reference
      Name		      "150 km"
      Ports		      [0, 0, 0, 0, 0, 1, 1]
      Position		      [235, 116, 310, 144]
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      SourceBlock	      "powerlib/Elements/Distributed Parameters Line"
      SourceType	      "Distributed Parameters Line"
      ShowPortLabels	      "FromPortIcon"
      SystemSampleTime	      "-1"
      FunctionWithSeparateData off
      RTWMemSecFuncInitTerm   "Inherit from model"
      RTWMemSecFuncExecute    "Inherit from model"
      RTWMemSecDataConstants  "Inherit from model"
      RTWMemSecDataInternal   "Inherit from model"
      RTWMemSecDataParameters "Inherit from model"
      Phases		      "1"
      Frequency		      "60"
      Resistance	      "0.011"
      Inductance	      "0.8674e-03"
      Capacitance	      "13.41e-09"
      Length		      "150"
      x1		      "[0 -120756.710653004;0.000102316423901542 -9790"
"8.8741896865;0.000204632847803084 -74915.3841500986;0.000306949271704625 -518"
"10.4466680859;0.000409265695606167 -28628.4336716439;0.000511582119507709 -54"
"03.83174971574]"
      x2		      "[0 -136848.367282306;0.000102316423901542 -1135"
"13.005926544;0.000204632847803084 -90008.777597249;0.000306949271704625 -6637"
"0.6482251605;0.000409265695606167 -42633.7829381371;0.000511582119507709 -188"
"33.493747956]"
      x3		      "[0 -959.074297245775;0.000102316423901542 -883."
"429401106842;0.000204632847803084 -806.470276275991;0.000306949271704625 -728"
".311410554772;0.000409265695606167 -649.069076532403;0.000511582119507709 -56"
"8.86115861352]"
      x4		      "[0 -501.015869720464;0.000102316423901542 -399."
"38577999001;0.000204632847803084 -297.161546289988;0.000306949271704625 -194."
"495241916543;0.000409265695606167 -91.5395978097266;0.000511582119507709 11.5"
"522246558104]"
      x5		      "0.000511582119507709"
      Measurements	      "None"
    }
    Block {
      BlockType		      Reference
      Name		      "150 km1"
      Ports		      [0, 0, 0, 0, 0, 1, 1]
      Position		      [410, 126, 485, 154]
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      SourceBlock	      "powerlib/Elements/Distributed Parameters Line"
      SourceType	      "Distributed Parameters Line"
      ShowPortLabels	      "FromPortIcon"
      SystemSampleTime	      "-1"
      FunctionWithSeparateData off
      RTWMemSecFuncInitTerm   "Inherit from model"
      RTWMemSecFuncExecute    "Inherit from model"
      RTWMemSecDataConstants  "Inherit from model"
      RTWMemSecDataInternal   "Inherit from model"
      RTWMemSecDataParameters "Inherit from model"
      Phases		      "1"
      Frequency		      "60"
      Resistance	      "0.011"
      Inductance	      "0.8674e-03"
      Capacitance	      "13.41e-09"
      Length		      "150"
      x1		      "[0 -126284.420527215;0.000102316423901542 -1030"
"09.215161606;0.000204632847803084 -79580.7687266743;0.000306949271704625 -560"
"33.9344166563;0.000409265695606167 -32403.7415448344;0.000511582119507709 -87"
"25.3434323783]"
      x2		      "[0 -136749.170157296;0.000102316423901542 -1138"
"44.863049278;0.000204632847803084 -90771.1952823772;0.000306949271704625 -675"
"62.492266378;0.000409265695606167 -44253.2802954778;0.000511582119507709 -208"
"78.2351854462]"
      x3		      "[0 -528.580606472671;0.000102316423901542 -447."
"831010078915;0.000204632847803084 -366.415200446344;0.000306949271704625 -284"
".454295338143;0.000409265695606167 -202.070223425663;0.000511582119507709 -11"
"9.385542901927]"
      x4		      "[0 -952.674213166175;0.000102316423901542 -856."
"242661836947;0.000204632847803084 -758.537326012862;0.000306949271704625 -659"
".703556477506;0.000409265695606167 -559.888382722415;0.000511582119507709 -45"
"9.240294219498]"
      x5		      "0.000511582119507709"
      Measurements	      "None"
    }
    Block {
      BlockType		      Demux
      Name		      "Demux"
      Ports		      [1, 3]
      Position		      [305, 332, 310, 378]
      BackgroundColor	      "black"
      ShowName		      off
      Outputs		      "3"
      Port {
	PortNumber		1
	Name			"Fault current (A)"
	RTWStorageClass		"Auto"
	DataLoggingNameMode	"SignalName"
      }
      Port {
	PortNumber		2
	Name			"Imag  T1 (A)"
	RTWStorageClass		"Auto"
	DataLoggingNameMode	"SignalName"
      }
    }
    Block {
      BlockType		      SubSystem
      Name		      "Double-click here for details"
      Ports		      []
      Position		      [815, 370, 842, 395]
      DropShadow	      on
      OpenFcn		      "showdemo(bdroot(gcb))"
      MinAlgLoopOccurrences   off
      RTWSystemCode	      "Auto"
      FunctionWithSeparateData off
      MaskHideContents	      off
      MaskDisplay	      "disp('?')"
      MaskIconFrame	      on
      MaskIconOpaque	      on
      MaskIconRotate	      "none"
      MaskIconUnits	      "autoscale"
      System {
	Name			"Double-click here for details"
	Location		[34, 118, 993, 712]
	Open			off
	ModelBrowserVisibility	off
	ModelBrowserWidth	200
	ScreenColor		"white"
	PaperOrientation	"landscape"
	PaperPositionMode	"auto"
	PaperType		"usletter"
	PaperUnits		"inches"
	TiledPaperMargins	[0.500000, 0.500000, 0.500000, 0.500000]
	TiledPageScale		1
	ShowPageBoundaries	off
	ZoomFactor		"100"
	Annotation {
	  Name			  "Demonstration"
	  Position		  [24, 262]
	  HorizontalAlignment	  "left"
	  VerticalAlignment	  "top"
	  ForegroundColor	  "blue"
	  FontSize		  14
	  FontWeight		  "bold"
	}
	Annotation {
	  Name			  "This demonstration ilustrates frequency-dom"
"ain and time-domain analysis of\na series-compensated  transmission system"
	  Position		  [24, 22]
	  HorizontalAlignment	  "left"
	  VerticalAlignment	  "top"
	  FontSize		  14
	  FontWeight		  "bold"
	}
	Annotation {
	  Name			  "Circuit  Description"
	  Position		  [19, 87]
	  HorizontalAlignment	  "left"
	  VerticalAlignment	  "top"
	  ForegroundColor	  "blue"
	  FontSize		  14
	  FontWeight		  "bold"
	}
	Annotation {
	  Name			  "A 735 kV, 300 km  line is used to  transmit"
" power from bus B1 (735 kV equivalent system) to bus B2 (315 kV equivalent). "
"\nIn order to simplify, only one phase of the system has been represented. \n"
"(A detailed simulation of  a three-phase series compensated network is presen"
"ted in demo power_3phseries and explained in the case studies\nsection of the"
" user's manual.)\n\nIn order to increase the transmission capacity, the line "
"is series compensated at its center by a capacitor representing 40% of the li"
"ne reactance.\nThe line is also shunt compensated at both ends by a 330 Mvar "
"shunt reactance (110 Mvar /phase). \nOpen the  Series Compensation subsystem."
" Notice that the series capacitor is protected by a metal oxide varistor (MOV"
") simulated by the Surge Arrester block.\nThe 250 MVA, 735 kV / 315 kV transf"
"ormer is a Saturable Transformer block simulating one phase of the three-phas"
"e 750 MVA transformer.  \nA  Multimeter block is used to monitor the fault cu"
"rrent as well as the flux and magnetizing current of the transformer."
	  Position		  [22, 107]
	  HorizontalAlignment	  "left"
	  VerticalAlignment	  "top"
	  FontName		  "Arial"
	  FontSize		  12
	}
	Annotation {
	  Name			  "You now study the transient performance of "
"this circuit when a 6-cycle fault is applied at node B2.\nFault is simulated "
"by the Breaker block. Switching times are defined in the Breaker block menu ("
"closing at t = 3 cycles and opening at t = 9 cycles). "
	  Position		  [22, 283]
	  HorizontalAlignment	  "left"
	  VerticalAlignment	  "top"
	  FontSize		  12
	}
	Annotation {
	  Name			  "Start the simulatiom and observe waveforms "
"on the two Scopes.\nAt t = 3 cycles, a line-to-ground fault is applied and th"
"e fault current reaches 10 kA (trace 1 of Scope2).\nDuring the fault, the MOV"
" conducts at every half cycle (trace 2 of Scope1) and the voltage across the "
"capacitor (trace 1 of Scope1)  is limited to 263 kV.\nAt t = 9 cycles, the fa"
"ult is cleared. The 15 Hz mode is clearly seen on the capacitor voltage (trac"
"e 1 of Scope1) and bus B2 voltage (trace 3 of Scope1).\nDuring fault the flux"
" in the transformer is trapped to around 1 pu. At fault clearing  the flux of"
"fset and 15 Hz component cause transformer\nsaturation (flux > 1.2 pu, trace "
"3 of Scope2), producing magnetizing current pulses (trace 2 of Scope2)."
	  Position		  [22, 481]
	  HorizontalAlignment	  "left"
	  VerticalAlignment	  "top"
	  FontSize		  12
	}
	Annotation {
	  Name			  "Frequency Analysis"
	  Position		  [24, 322]
	  HorizontalAlignment	  "left"
	  VerticalAlignment	  "top"
	  ForegroundColor	  "blue"
	  FontName		  "Arial"
	  FontSize		  12
	  FontWeight		  "bold"
	}
	Annotation {
	  Name			  "Time Domain Simulation - Fault at Bus B2"
	  Position		  [19, 457]
	  HorizontalAlignment	  "left"
	  VerticalAlignment	  "top"
	  ForegroundColor	  "blue"
	  FontName		  "Arial"
	  FontSize		  12
	  FontWeight		  "bold"
	}
	Annotation {
	  Name			  "In order to understand the transient behavi"
"or of this series-compensated network, a frequency analysis is first preforme"
"d by measuring the Impedance at node B2.\nThis  measurement is performed by t"
"he Impedance Measurement block connected at node B2. \nOpen the Powergui and "
"in the Tools menu select 'Impedance vs Frequency Mesurement'. Click on Displa"
"y to compute and display the impedance for the 0 - 500 Hz range.\nThe impedan"
"ce curves show two main parallel resonances (impedance maxima and phase inver"
"sion), corresponding to 15 Hz and 300 Hz modes. \nThe 15 Hz mode is due to a "
"parallel resonance of the series capacitance and the two shunt reactances.\nT"
"he 300 Hz mode is  mainly due to resonance of shunt line capacitance and seri"
"es reactance of the transmission system. \nThese two modes are likely to be e"
"xcited at fault clearing."
	  Position		  [19, 345]
	  HorizontalAlignment	  "left"
	  VerticalAlignment	  "top"
	  FontSize		  12
	}
	Annotation {
	  Name			  "G. Sybille (Hydro-Quebec)"
	  Position		  [26, 60]
	  HorizontalAlignment	  "left"
	  VerticalAlignment	  "top"
	  FontName		  "Arial"
	  FontSize		  12
	}
      }
    }
    Block {
      BlockType		      Reference
      Name		      "Fault"
      Ports		      [0, 0, 0, 0, 0, 1, 1]
      Position		      [625, 190, 665, 230]
      Orientation	      "down"
      ForegroundColor	      "red"
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      SourceBlock	      "powerlib/Elements/Breaker"
      SourceType	      "Breaker"
      ShowPortLabels	      "FromPortIcon"
      SystemSampleTime	      "-1"
      FunctionWithSeparateData off
      RTWMemSecFuncInitTerm   "Inherit from model"
      RTWMemSecFuncExecute    "Inherit from model"
      RTWMemSecDataConstants  "Inherit from model"
      RTWMemSecDataInternal   "Inherit from model"
      RTWMemSecDataParameters "Inherit from model"
      BreakerResistance	      "0.01"
      InitialState	      "0"
      SnubberResistance	      "inf"
      SnubberCapacitance      "0"
      SwitchingTimes	      "[ 3/60  9/60 ]"
      External		      off
      Measurements	      "Branch current"
      MoreParameters	      off
      NoBreakLoop	      off
    }
    Block {
      BlockType		      Reference
      Name		      "Ground1"
      Ports		      [0, 0, 0, 0, 0, 1]
      Position		      [814, 240, 836, 265]
      Orientation	      "down"
      ShowName		      off
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      SourceBlock	      "powerlib/Elements/Ground"
      SourceType	      "Ground"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
    }
    Block {
      BlockType		      Reference
      Name		      "Ground2"
      Ports		      [0, 0, 0, 0, 0, 1]
      Position		      [699, 235, 721, 260]
      Orientation	      "down"
      ShowName		      off
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      SourceBlock	      "powerlib/Elements/Ground"
      SourceType	      "Ground"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
    }
    Block {
      BlockType		      Reference
      Name		      "Ground3"
      Ports		      [0, 0, 0, 0, 0, 1]
      Position		      [634, 285, 656, 310]
      Orientation	      "down"
      ShowName		      off
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      SourceBlock	      "powerlib/Elements/Ground"
      SourceType	      "Ground"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
    }
    Block {
      BlockType		      Reference
      Name		      "Ground4"
      Ports		      [0, 0, 0, 0, 0, 1]
      Position		      [529, 285, 551, 310]
      Orientation	      "down"
      ShowName		      off
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      SourceBlock	      "powerlib/Elements/Ground"
      SourceType	      "Ground"
      PhysicalDomain	      "powersysdomain"
      SubClassName	      "unknown"
      LeftPortType	      "p1"
      RightPortType	      "p1"
      LConnTagsString	      "a"
    }
    Block {
      BlockType		      Reference
      Name		      "Ground5"
      Ports		      [0, 0, 0, 0, 0, 1]
      Position		      [484, 285, 506, 310]
      Orientation	      "down"
      ShowName		      off
      AttributesFormatString  "\\n"
      DialogController	      "POWERSYS.PowerSysDialog"
      SourceBlock	      "powerlib/Elements/Ground"