⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 pack.h

📁 用AVR453开发的电池保护板的C语言程序,希望对大家有用!
💻 H
字号:
/* This file has been prepared for Doxygen automatic documentation generation.*/
/*! \file *********************************************************************
 *
 * \brief
 *       Battery pack definitions.
 *
 *       This file creates the *PACK's* voltage and current figures, based on
 *       both the individual cell specifications and the pack configuration.
 *
 * \par Application note:
 *      AVR453: Smart Battery Reference Design
 *
 * \par Documentation:
 *      For comprehensive code documentation, supported compilers, compiler
 *      settings and supported devices see readme.html
 *
 * \author
 *      Atmel Corporation: http://www.atmel.com \n
 *      Support email: avr@atmel.com \n
 *      Original author: Rob G. Fries - Apt Inc.\n
 *
 * $Revision: 2687 $
 * $URL: http://revisor.norway.atmel.com/AppsAVR8/avr453_Smart_battery_reference_design/tags/20071112_release/code/pack.h $
 * $Date: 2007-11-12 10:39:44 +0100 (ma, 12 nov 2007) $  \n
 ******************************************************************************/



#include "LG18450.h"	//Change this #include file if using a different cell.
#include "pack_cfg.h"	//Adjust this file for the number of cells in series and in parallel.


// DO NOT MODIFY THE FOLLOWING DEFINITIONS!
// These are derived from the included files (above), so modify those instead.

#define PACK_DESIGNCAPTYP (CELL_DESIGNCAPTYP * PACKWIDTH)	/* in mAh, typical capacity for entire pack   */
#define PACK_DESIGNCAPC5  (CELL_DESIGNCAPC5 * PACKWIDTH)	/* in mAh, minimum capacity at C/5 for entire pack */

#define PACK_NOMINALV     (CELL_NOMINALV * PACKSTACK)		/* in mV, typical, entire pack V when fully charged */
#define PACK_MINV         (CELL_MINV * PACKSTACK)		/* in mV, absolute low-end voltage permitted  */
#define PACK_DISCHG_C5    (CELL_DISCHG_C5 * PACKWIDTH)		/* discharge current (mA) for C/5 rate        */
#define PACK_DISCHG_MAX   (CELL_DISCHG_MAX * PACKWIDTH)		/* maximum permissible discharge current (mA) */

#define PACK_CCCV_V       (CELL_CCCV_V * PACKSTACK)		/* Constant Current / Constant Voltage charging mode, applied voltage (mV) */
#define PACK_CCCV_C       (CELL_CCCV_C * PACKWIDTH)		/* Constant Current / Constant Voltage charging mode, applied current (mA) */
#define PACK_CCCV_TERMC   (CELL_CCCV_TERMC * PACKWIDTH) /* Constant Current / Constant Voltage charging mode, charge-termination current threshold (mA) */
#define PACK_MAX_CHG_C    (CELL_MAX_CHG_C * PACKWIDTH)	/* Maximum permissible charging current (mA)  */


/* Extra calculations we perform on Constants to make code lighter... */
#define PACK_DESIGNCAPMW  ((PACK_DESIGNCAPTYP/100) * (PACK_NOMINALV/100))
#define PACK_PROTECT_DUV  {BPDUV = (0x01<<4) | (0x0D << 0);}	/* 1000mS, 8.80V*90% due to h/w issue */
#define PACK_PROTECT_SHORT {BPSCD = 0;}				/* 20A into 5mOhm = 100mV */
#define PACK_PROTECT_OVERC {BPOCD = 0<<4 | 0<<0;}		/* 10A discharge, 10A charge */
#define PACK_PROTECT_TIME  {CBPTR = 1<<4 | 5<<0;}		/* 122uS short-circuit, 10mS overcurrent Chg/Dischg */


#define PACK_HIBERNATEAMOUNT 1					/* used to update RunningAcc while in Hibernate mode; see WakeUp_ISR().  */

/*
1.1.4	Battery protection detection levels
The characterization of the Deep Under-voltage, Over-current and Short-circuit detection levels;深度低电压,过流,短路
show that the actual真实 thresholds are typically 10% below the numbers given in the datasheet. This;
is caused by parasitic elements in the layout that are not included in the simulation models.
The spread 展开in these thresholds开始 are however无论如何 in the expected预期范围 range of +/-5% for Over-current
detection levels, and +/-3% for Deep Under-voltage detection levels.

Detailed characterization data列出描述数据 will be given in the Analog characterization report.类似描述报告

Workaround for ATmega406 rev. D:工作区
As long as the actual range for these detection levels covers the required range for the
application used for qualification of ATmega406 rev. D, a correct detection level can always be found.

ATmega406 fix:
We assume 设想that it is sufficient to update the datasheet with the actual detection levels found
during characterization. If not, the thresholds can be tuned to better fit the specification in the datasheet.

Battery Protection Parameter Lock Register ?BPPLR:0XF8
Battery Protection Control Register ?BPCR:0XF7
Current Battery Protection Timing Register ?CBPTR:0XF6
Battery Protection Over-current Detection Level Register ?BPOCD:0XF5
Battery Protection Short-circuit Detection Level Register ?BPSCD:0XF4
Battery Protection Deep Under Voltage Register ?BPDUV:0XF3
Battery Protection Interrupt Register ?BPIR:0XF2

*/