📄 idx_brch.m
字号:
function [F_BUS, T_BUS, BR_R, BR_X, BR_B, RATE_A, RATE_B, ... RATE_C, TAP, SHIFT, BR_STATUS, PF, QF, PT, QT, MU_SF, MU_ST] = idx_brch%IDX_BRCH Defines constants for named column indices to branch matrix.% [F_BUS, T_BUS, BR_R, BR_X, BR_B, RATE_A, RATE_B, ...% RATE_C, TAP, SHIFT, BR_STATUS, PF, QF, PT, QT, MU_SF, MU_ST] = idx_brch%% Some examples of usage, after defining the constants using the line above,% are:%% branch(4, BR_STATUS) = 0; % take branch 4 out of service% Ploss = branch(:, PF) + branch(:, PT); % compute real power loss vector% % The index, name and meaning of each column of the branch matrix is given% below:%% columns 1-11 must be included in input matrix (in case file)% 1 BUS_I bus number (1 to 29997)% 1 F_BUS f, from bus number% 2 T_BUS t, to bus number% 3 BR_R r, resistance (p.u.)% 4 BR_X x, reactance (p.u.)% 5 BR_B b, total line charging susceptance (p.u.)% 6 RATE_A rateA, MVA rating A (long term rating)% 7 RATE_B rateB, MVA rating B (short term rating)% 8 RATE_C rateC, MVA rating C (emergency rating)% 9 TAP ratio, transformer off nominal turns ratio% 10 SHIFT angle, transformer phase shift angle (degrees)% 11 BR_STATUS initial branch status, 1 - in service, 0 - out of service%% columns 12-15 are added to matrix after power flow or OPF solution% they are typically not present in the input matrix% 12 PF real power injected at "from" bus end (MW)% 13 QF reactive power injected at "from" bus end (MVAr)% 14 PT real power injected at "to" bus end (MW)% 15 QT reactive power injected at "to" bus end (MVAr)%% columns 14-17 are added to matrix after OPF solution% they are typically not present in the input matrix% (assume OPF objective function has units, u)% 16 MU_SF Kuhn-Tucker multiplier on MVA limit at "from" bus (u/MVA)% 17 MU_ST Kuhn-Tucker multiplier on MVA limit at "to" bus (u/MVA)% MATPOWER% $Id: idx_brch.m,v 1.5 2004/12/15 22:46:27 ray Exp $% by Ray Zimmerman, PSERC Cornell% Copyright (c) 1996-2004 by Power System Engineering Research Center (PSERC)% See http://www.pserc.cornell.edu/matpower/ for more info.%% define the indicesF_BUS = 1; %% f, from bus numberT_BUS = 2; %% t, to bus numberBR_R = 3; %% r, resistance (p.u.)BR_X = 4; %% x, reactance (p.u.)BR_B = 5; %% b, total line charging susceptance (p.u.)RATE_A = 6; %% rateA, MVA rating A (long term rating)RATE_B = 7; %% rateB, MVA rating B (short term rating)RATE_C = 8; %% rateC, MVA rating C (emergency rating)TAP = 9; %% ratio, transformer off nominal turns ratioSHIFT = 10; %% angle, transformer phase shift angle (degrees)BR_STATUS = 11; %% initial branch status, 1 - in service, 0 - out of service%% included in power flow solution, not necessarily in inputPF = 12; %% real power injected at "from" bus end (MW) (not in PTI format)QF = 13; %% reactive power injected at "from" bus end (MVAr) (not in PTI format)PT = 14; %% real power injected at "to" bus end (MW) (not in PTI format)QT = 15; %% reactive power injected at "to" bus end (MVAr) (not in PTI format)%% included in opf solution, not necessarily in input%% assume objective function has units, uMU_SF = 16; %% Kuhn-Tucker multiplier on MVA limit at "from" bus (u/MVA)MU_ST = 17; %% Kuhn-Tucker multiplier on MVA limit at "to" bus (u/MVA)return;
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -