⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 top.v

📁 elevaters used in transportation
💻 V
字号:
module top(maintenance_alarm,  //Signal indicating that the maintenance alarm has been triggered.                exp_floor_disp,     //14 bit signal use to indicate the current floor of the express elevator on two 7-seg LED displays.           exp_move_up,        //Signal asserted when Express Car is moving up           exp_move_down,      //Signal asserted when Express Car is moving down            main_floor_disp,    //14 bit signal use to indicate the current floor of the main elevator on two 7-seg LED displays.           main_move_up,       //Signal asserted when main Car is moving up	        main_move_down,     //Signal asserted when main Car is moving down            data_enable,        //Controls reading of Maintenance log by elevator maintenance worker           write_enable,       //Controls writing to Maintenance log by elevator maintenance worker           maint_data,         //9 bit signal indicating a request from one of the nine floors to have the elevator come to that floor to pick up a passenger           main_external_requests, //8 bit signal for data input and extraction from maintenance log. 	        exp_request_up,      //Outside request to go up in the Express car           exp_request_down,    //Outside request to go down in the Express car.           main_sensor_trip,    //Trip signal indicating that the Elevator is "stuck", issued by passenger inside main car           main_internal_requests,  //9 bit signal indicating requested floor from inside the main elevator car           main_temp,           //8 bit signal representing the temperature in the main car           exp_update_enable,   //enables updating or changing the security code for the express car	        exp_input_code,      //14 bit signal this is the security code that must be entered in the express car to access the 10th floor           exp_temp,            //8 bit signal representing the temperature in the express car           reset,               //Sets the Elevator cars to a know position/status representing the power-on state of the Elevator.           clk);                // System clock for the Elevator design.//define the ports of the top level designoutput maintenance_alarm;                       output [13:0] exp_floor_disp;output exp_move_up, exp_move_down;output [13:0] main_floor_disp;output main_move_up, main_move_down;input data_enable, write_enable;input [8:0] main_external_requests;input exp_request_up, exp_request_down;input main_sensor_trip;input [8:0] main_internal_requests;input [7:0] main_temp;input exp_update_enable;input [13:0] exp_input_code;input [7:0] exp_temp;input reset, clk;inout [7:0] maint_data;//setup the master clock on a global bufferwire gclk;BUFG globalbuffer(.O(gclk), .I(clk));//declare the signals going from the controller to the main carwire [3:0] c2m_main_car_destination, c2m_main_current_floor;//declare the signals going from the controller to the express carwire [3:0] c2e_exp_current_floor;wire c2e_exp_car_destination, c2e_check_permission;//declare the signals going from the main car to the controllerwire [8:0] m2c_main_internal_requests;wire m2c_main_stuck, m2c_main_maintenance;//declare the signals going from the express car to the controllerwire e2c_exp_maintenance, e2c_secure, e2c_reject;//setup the bidirectional portwire [7:0] maint_data_out;reg [7:0] maint_data_in;// Code for bidirectional port// Input IOB FFalways @ (posedge gclk) begin	if (reset)		maint_data_in = 8'd0;	else		maint_data_in = maint_data;end // IOB Tri-stateassign maint_data = data_enable ? 8'bz : maint_data_out;//instantiate the modulescontroller Control_Module(	.main_car_destination(c2m_main_car_destination),				.express_car_destination(c2e_exp_car_destination),				.check_permission(c2e_check_permission),				.maintenance_alarm(maintenance_alarm),				.current_floor(c2m_main_current_floor),				.express_floor(c2e_exp_current_floor),				.internal_requests(m2c_main_internal_requests),				.main_maintenance(m2c_main_maintenance),				.express_maintenance(e2c_exp_maintenance),				.secure(e2c_secure),				.reject(e2c_reject),				.external_requests(main_external_requests),				.express_up(exp_request_up),				.express_down(exp_request_down),				.stuck(m2c_main_stuck),				.reset(reset),				.clk(gclk));elevator_car Main_Car(	.stuck(m2c_main_stuck),			.main_requests(m2c_main_internal_requests),			.maintenance_request(m2c_main_maintenance),			.floor_display(main_floor_disp),			.move_up(main_move_up),			.move_down(main_move_down),			.floor(c2m_main_current_floor),			.sensor_trip(main_sensor_trip),			.internal_requests(main_internal_requests),			.destination(c2m_main_car_destination),			.temperature(main_temp),			.reset(reset),			.clk(gclk));express_car Express_Car(	.maintenance_request(e2c_exp_maintenance),				.secure(e2c_secure),				.reject(e2c_reject),				.floor(c2e_exp_current_floor),				.move_up(exp_move_up),				.move_down(exp_move_down),				.floor_display(exp_floor_disp),				.destination(c2e_exp_car_destination),				.temperature(exp_temp),				.input_code(exp_input_code),				.update_enable(exp_update_enable),				.check_permission(c2e_check_permission),				.reset(reset),				.clk(gclk));							tracking Tracking_Module(	.maint_data_out(maint_data_out),				.maint_data_in(maint_data_in),				.data_enable(data_enable),				.write_enable(write_enable),				.reset(reset),				.clk(gclk));endmodule

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -