⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2115.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 3 页
字号:
     frCircuitIfIndex OBJECT-TYPE         SYNTAX   InterfaceIndex         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "The ifIndex Value of the ifEntry this virtual circuit            is layered onto."         ::= { frCircuitEntry 1 }     frCircuitDlci OBJECT-TYPE         SYNTAX   DLCI         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "The Data Link Connection Identifier for this virtual            circuit."         REFERENCE            "American National Standard T1.618-1991, Section 3.3.6"         ::= { frCircuitEntry 2 }     frCircuitState OBJECT-TYPE         SYNTAX   INTEGER    {                     invalid (1),                     active (2),                     inactive (3)                  }         MAX-ACCESS   read-create         STATUS   current         DESCRIPTION            "Indicates whether the particular virtual circuit is            operational.  In the absence of a Data Link Connection            Management Interface, virtual circuit entries (rows)            may be created by setting virtual circuit state to            'active', or deleted by changing Circuit state to            'invalid'.            Whether or not the row actually disappears is left to            the implementation, so this object may actually read as            'invalid' for some arbitrary length of time.  It is            also legal to set the state of a virtual circuit to            'inactive' to temporarily disable a given circuit.            The use of 'invalid' is deprecated in this SNMP Version            2 MIB, in favor of frCircuitRowStatus."         DEFVAL { active }         ::= { frCircuitEntry 3 }     frCircuitReceivedFECNs OBJECT-TYPE         SYNTAX   Counter32         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "Number of frames received from the network indicating            forward congestion since the virtual circuit was            created.  This occurs when the remote DTE sets the FECN            flag, or when a switch in the network enqueues the            frame to a trunk whose transmission queue is            congested."         REFERENCE            "American National Standard T1.618-1991, Section 3.3.3"         ::= { frCircuitEntry 4 }     frCircuitReceivedBECNs OBJECT-TYPE         SYNTAX   Counter32         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "Number of frames received from the network indicating            backward congestion since the virtual circuit was            created.  This occurs when the remote DTE sets the BECN            flag, or when a switch in the network receives the            frame from a trunk whose transmission queue is            congested."         REFERENCE            "American National Standard T1.618-1991, Section 3.3.4"         ::= { frCircuitEntry 5 }     frCircuitSentFrames OBJECT-TYPE         SYNTAX   Counter32         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "The number of frames sent from this virtual circuit            since it was created."         ::= { frCircuitEntry 6 }     frCircuitSentOctets OBJECT-TYPE         SYNTAX   Counter32         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "The number of octets sent from this virtual circuit            since it was created.  Octets counted are the full            frame relay header and the payload, but do not include            the flag characters or CRC."         ::= { frCircuitEntry 7 }     frCircuitReceivedFrames OBJECT-TYPE         SYNTAX   Counter32         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "Number of frames received over this virtual circuit            since it was created."         ::= { frCircuitEntry 8 }     frCircuitReceivedOctets OBJECT-TYPE         SYNTAX   Counter32         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "Number of octets received over this virtual circuit            since it was created.  Octets counted include the full            frame relay header, but do not include the flag            characters or the CRC."         ::= { frCircuitEntry 9 }     frCircuitCreationTime OBJECT-TYPE         SYNTAX   TimeStamp         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "The value of sysUpTime when the virtual circuit was            created, whether by the Data Link Connection Management            Interface or by a SetRequest."         ::= { frCircuitEntry 10 }     frCircuitLastTimeChange OBJECT-TYPE         SYNTAX   TimeStamp         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "The value of sysUpTime when last there was a change in            the virtual circuit state"         ::= { frCircuitEntry 11 }     frCircuitCommittedBurst OBJECT-TYPE         SYNTAX   Integer32(0..2147483647)         MAX-ACCESS   read-create         STATUS   current         DESCRIPTION            "This variable indicates the maximum amount of data, in            bits, that the network agrees to transfer under normal            conditions, during the measurement interval."         REFERENCE            "American National Standard T1.617-1991, Section            6.5.19"         DEFVAL   { 0 }  -- the default indicates no commitment         ::= { frCircuitEntry 12 }     frCircuitExcessBurst OBJECT-TYPE         SYNTAX   Integer32(0..2147483647)         MAX-ACCESS   read-create         STATUS   current         DESCRIPTION            "This variable indicates the maximum amount of            uncommitted data bits that the network will attempt to            deliver over the measurement interval.            By default, if not configured when creating the entry,            the Excess Information Burst Size is set to the value            of ifSpeed."         REFERENCE            "American National Standard T1.617-1991, Section            6.5.19"         ::= { frCircuitEntry 13 }     frCircuitThroughput OBJECT-TYPE         SYNTAX   Integer32(0..2147483647)         MAX-ACCESS   read-create         STATUS   current         DESCRIPTION            "Throughput is the average number of 'Frame Relay            Information Field' bits transferred per second across a            user network interface in one direction, measured over            the measurement interval.            If the configured committed burst rate and throughput            are both non-zero, the measurement interval, T, is                T=frCircuitCommittedBurst/frCircuitThroughput.            If the configured committed burst rate and throughput            are both zero, the measurement interval, T, is                       T=frCircuitExcessBurst/ifSpeed."         REFERENCE            "American National Standard T1.617-1991, Section            6.5.19"         DEFVAL {0}  -- the default value of Throughput is                     -- "no commitment".         ::= { frCircuitEntry 14 }     frCircuitMulticast OBJECT-TYPE         SYNTAX   INTEGER    {                     unicast   (1),                     oneWay    (2),                     twoWay    (3),                     nWay      (4)                     }         MAX-ACCESS   read-create         STATUS   current         DESCRIPTION            "This indicates whether this VC is used as a unicast VC            (i.e. not multicast) or the type of multicast service            subscribed to"         REFERENCE            "Frame Relay PVC Multicast Service and Protocol            Description Implementation: FRF.7 Frame Relay Forum            Technical Committe October 21, 1994"              DEFVAL {unicast}                          -- the default value of frCircuitMulticast is                          -- "unicast" (not a multicast VC).              ::= { frCircuitEntry 15 }     frCircuitType OBJECT-TYPE         SYNTAX   INTEGER    {                     static  (1),                     dynamic (2)                  }         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "Indication of whether the VC was manually created            (static), or dynamically created (dynamic) via the data            link control management interface."         ::= { frCircuitEntry 16 }     frCircuitDiscards OBJECT-TYPE         SYNTAX   Counter32         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "The number of inbound frames dropped because of format            errors, or because the VC is inactive."         ::= { frCircuitEntry 17 }     frCircuitReceivedDEs OBJECT-TYPE         SYNTAX   Counter32         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "Number of frames received from the network indicating            that they were eligible for discard since the virtual            circuit was created.  This occurs when the remote DTE            sets the DE flag, or when in remote DTE's switch            detects that the frame was received as Excess Burst            data."         REFERENCE            "American National Standard T1.618-1991, Section 3.3.4"         ::= { frCircuitEntry 18 }     frCircuitSentDEs OBJECT-TYPE         SYNTAX   Counter32         MAX-ACCESS   read-only         STATUS   current         DESCRIPTION            "Number of frames sent to the network indicating that            they were eligible for discard since the virtual            circuit was created.   This occurs when the local DTE            sets the DE flag, indicating that during Network            congestion situations those frames should be discarded            in preference of other frames sent without the DE bit            set."         REFERENCE            "American National  Standard  T1.618-1991, Section            3.3.4"        ::= { frCircuitEntry 19 }     frCircuitLogicalIfIndex OBJECT-TYPE         SYNTAX  InterfaceIndex         MAX-ACCESS read-create         STATUS  current         DESCRIPTION            "Normally the same value as frDlcmiIfIndex, but            different when an implementation associates a virtual            ifEntry with a DLC or set of DLCs in order to associate            higher layer objects such as the ipAddrEntry with a            subset of the virtual circuits on a Frame Relay            interface. The type of such ifEntries is defined by the            higher layer object; for example, if PPP/Frame Relay is            implemented, the ifType of this ifEntry would be PPP.            If it is not so defined, as would be the case with an            ipAddrEntry, it should be of type Other."        ::= { frCircuitEntry 20 }     frCircuitRowStatus OBJECT-TYPE         SYNTAX   RowStatus         MAX-ACCESS   read-create         STATUS   current         DESCRIPTION            "This object is used to create a new row or modify or            destroy an existing row in the manner described in the            definition of the RowStatus textual convention.            Writable objects in the table may be written in any            RowStatus state."         ::= { frCircuitEntry 21 }     --     --  Error Table     -- The table describing errors encountered on each Frame     -- Relay Interface.     frErrTable OBJECT-TYPE         SYNTAX   SEQUENCE OF FrErrEntry         MAX-ACCESS   not-accessible         STATUS   current         DESCRIPTION            "A table containing information about Errors on the            Frame Relay interface.  Discontinuities in the counters            contained in this table are the same as apply to the            ifEntry associated with the Interface."         ::= { frameRelayDTE 3 }     frErrEntry OBJECT-TYPE         SYNTAX   FrErrEntry         MAX-ACCESS   not-accessible         STATUS   current         DESCRIPTION            "The error information for a single frame relay            interface."         INDEX { frErrIfIndex }         ::= { frErrTable 1 }     FrErrEntry ::=         SEQUENCE {             frErrIfIndex            InterfaceIndex,

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -