📄 rfc2127.mib
字号:
the hyperchannel. If since system startup there was no call on this interface, this object has a value of false(2)." REFERENCE "Q.931 [8], chapter 4.5.5." ::= { isdnBearerEntry 8 }isdnBearerCallSetupTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when the ISDN setup message for the current or last call was sent or received. If since system startup there has been no call on this interface, this object has a value of zero." ::= { isdnBearerEntry 9 }isdnBearerCallConnectTime OBJECT-TYPE SYNTAX TimeStamp MAX-ACCESS read-only STATUS current DESCRIPTION "The value of sysUpTime when the ISDN connect message for the current or last call was sent or received. If since system startup there has been no call on this interface, this object has a value of zero." ::= { isdnBearerEntry 10 }isdnBearerChargedUnits OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of charged units for the current or last connection. For incoming calls or if charging information is not supplied by the switch, the value of this object is zero." ::= { isdnBearerEntry 11 }-- ISDN signaling groupisdnSignalingGroup OBJECT IDENTIFIER ::= { isdnMibObjects 3 }-- signaling channel configuration table-- There is one entry in this table for each Terminal Endpoint-- (link layer connection to the switch).-- Usually, there is one endpoint per D channel. In some-- cases, however, there can be multiple endpoints.-- Thus, entries in this table can be created and deleted.-- This also means the creation of an associated ifEntry.---- D channel backup and NFAS trunks are handled using the-- ifStack table.-- In case of D channel backup, there are multiple-- Data Link Layer (LAPD) interfaces. Only one interface is-- active; all others are dormant(5).-- In case of NFAS trunks, one lower interface is the-- LAPD interface, while the other lower interfaces are physical-- interfaces.-- If directory number and calling address differ from each other-- or multiple directory numbers are being used,-- the isdnDirectoryTable has to be used to enter such-- directory numbers.isdnSignalingGetIndex OBJECT-TYPE SYNTAX TestAndIncr MAX-ACCESS read-write STATUS current DESCRIPTION "The recommended procedure for selecting a new index for isdnSignalingTable row creation is to GET the value of this object, and then to SET the object with the same value. If the SET operation succeeds, the manager can use this value as an index to create a new row in this table." REFERENCE "RFC1903, TestAndIncr textual convention." ::= { isdnSignalingGroup 1 }isdnSignalingTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdnSignalingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "ISDN signaling table containing configuration and operational parameters for all ISDN signaling channels on this managed device." ::= { isdnSignalingGroup 2 }isdnSignalingEntry OBJECT-TYPE SYNTAX IsdnSignalingEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ISDN Signaling Table. To create a new entry, only isdnSignalingProtocol needs to be specified before isdnSignalingStatus can become active(1)." INDEX { isdnSignalingIndex } ::= { isdnSignalingTable 1 }IsdnSignalingEntry ::= SEQUENCE { isdnSignalingIndex INTEGER, isdnSignalingIfIndex InterfaceIndex, isdnSignalingProtocol IsdnSignalingProtocol, isdnSignalingCallingAddress DisplayString, isdnSignalingSubAddress DisplayString, isdnSignalingBchannelCount Integer32, isdnSignalingInfoTrapEnable INTEGER, isdnSignalingStatus RowStatus }isdnSignalingIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index value which uniquely identifies an entry in the isdnSignalingTable." ::= { isdnSignalingEntry 1 }isdnSignalingIfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "The ifIndex value of the interface associated with this signaling channel." ::= { isdnSignalingEntry 2 }isdnSignalingProtocol OBJECT-TYPE SYNTAX IsdnSignalingProtocol MAX-ACCESS read-create STATUS current DESCRIPTION "The particular protocol type supported by the switch providing access to the ISDN network to which this signaling channel is connected." ::= { isdnSignalingEntry 3 }isdnSignalingCallingAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "The ISDN Address to be assigned to this signaling channel. More specifically, this is the 'Calling Address information element' as being passed to the switch in outgoing call setup messages. It can be an EAZ (1TR6), a calling number (DSS1, ETSI) or any other number necessary to identify a signaling interface. If there is no such number defined or required, this is a zero length string. It is represented in DisplayString form. Incoming calls can also be identified by this number. If the Directory Number, i.e. the Called Number in incoming calls, is different to this number, the isdnDirectoryTable has to be used to specify all possible Directory Numbers. The format of this information largely depends on the type of switch or PBX the device is connected to. Therefore, the detailed format of this information is not specified and is implementation dependent. If possible, the agent should implement this information using the E.164 number format. In this case, the number must start with '+'. Otherwise, IA5 number digits must be used." REFERENCE "ITU-T E.164, Q.931 chapter 4.5.10" DEFVAL { "" } ::= { isdnSignalingEntry 4 }isdnSignalingSubAddress OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "Supplementary information to the ISDN address assigned to this signaling channel. Usually, this is the subaddress as defined in Q.931. If there is no such number defined or required, this is a zero length string. The subaddress is used for incoming calls as well as for outgoing calls. The subaddress is an user supplied string of up to 20 IA5 characters and is transmitted transparently through the network." REFERENCE "ITU-T I.330, Q.931 chapter 4.5.11" DEFVAL { "" } ::= { isdnSignalingEntry 5 }isdnSignalingBchannelCount OBJECT-TYPE SYNTAX Integer32 (1..65535) MAX-ACCESS read-create STATUS current DESCRIPTION "The total number of B channels (bearer channels) managed by this signaling channel. The default value of this object depends on the physical interface type and is either 2 for Basic Rate interfaces or 24 (30) for Primary Rate interfaces." ::= { isdnSignalingEntry 6 }isdnSignalingInfoTrapEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } MAX-ACCESS read-create STATUS current DESCRIPTION "Indicates whether isdnMibCallInformation traps should be generated for calls on this signaling channel." DEFVAL { disabled } ::= { isdnSignalingEntry 7 }isdnSignalingStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "This object is used to create and delete rows in the isdnSignalingTable." ::= { isdnSignalingEntry 8 }-- Signaling channel statistics table-- There is one entry for each signaling connection-- in this table.-- Note that the ifEntry also has some statistics information.isdnSignalingStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdnSignalingStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "ISDN signaling table containing statistics information for all ISDN signaling channels on this managed device. Only statistical information which is not already being counted in the ifTable is being defined in this table." ::= { isdnSignalingGroup 3 }isdnSignalingStatsEntry OBJECT-TYPE SYNTAX IsdnSignalingStatsEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the ISDN Signaling statistics Table." AUGMENTS { isdnSignalingEntry } ::= { isdnSignalingStatsTable 1 }IsdnSignalingStatsEntry ::= SEQUENCE { isdnSigStatsInCalls Counter32, isdnSigStatsInConnected Counter32, isdnSigStatsOutCalls Counter32, isdnSigStatsOutConnected Counter32, isdnSigStatsChargedUnits Counter32 }isdnSigStatsInCalls OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of incoming calls on this interface." ::= { isdnSignalingStatsEntry 1 }isdnSigStatsInConnected OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of incoming calls on this interface which were actually connected." ::= { isdnSignalingStatsEntry 2 }isdnSigStatsOutCalls OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outgoing calls on this interface." ::= { isdnSignalingStatsEntry 3 }isdnSigStatsOutConnected OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of outgoing calls on this interface which were actually connected." ::= { isdnSignalingStatsEntry 4 }isdnSigStatsChargedUnits OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of charging units on this interface since system startup. Only the charging units applying to the local interface, i.e. for originated calls or for calls with 'Reverse charging' being active, are counted here." ::= { isdnSignalingStatsEntry 5 }---- The LAPD tableisdnLapdTable OBJECT-TYPE SYNTAX SEQUENCE OF IsdnLapdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table containing configuration and statistics information for all LAPD (D channel Data Link) interfaces on this managed device. Only statistical information which is not already being counted in the ifTable is being defined in this table." ::= { isdnSignalingGroup 4 }isdnLapdEntry OBJECT-TYPE SYNTAX IsdnLapdEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the LAPD Table." INDEX { ifIndex } ::= { isdnLapdTable 1 }IsdnLapdEntry ::= SEQUENCE { isdnLapdPrimaryChannel TruthValue, isdnLapdOperStatus INTEGER, isdnLapdPeerSabme Counter32, isdnLapdRecvdFrmr Counter32 }isdnLapdPrimaryChannel OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "If set to true(1), this D channel is the designated primary D channel if D channel backup is active. There must be exactly one primary D channel configured. If D channel backup is not used, this object has a value of true(1)." REFERENCE "Q.931 [8], Annex F, D channel backup procedures." ::= { isdnLapdEntry 1 }isdnLapdOperStatus OBJECT-TYPE SYNTAX INTEGER { inactive(1), l1Active(2), l2Active(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational status of this interface: inactive all layers are inactive l1Active layer 1 is activated, layer 2 datalink not established l2Active layer 1 is activated, layer 2 datalink established." ::= { isdnLapdEntry 2 }isdnLapdPeerSabme OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of peer SABME frames received on this interface. This is the number of peer-initiated new connections on this interface." ::= { isdnLapdEntry 3 }isdnLapdRecvdFrmr OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of LAPD FRMR response frames received. This is the number of framing errors on this interface." ::= { isdnLapdEntry 4 }---- Optional groups follow here.-- The Terminal Endpoint group and table-- This table is required only if TEI values or SPID numbers-- have to be entered.-- The ifIndex values for this table are identical to those of-- the isdnSignalingChannel table.isdnEndpointGroup OBJECT IDENTIFIER ::= { isdnMibObjects 4 }isdnEndpointGetIndex OBJECT-TYPE SYNTAX TestAndIncr MAX-ACCESS read-write STATUS current DESCRIPTION "The recommended procedure for selecting a new index for isdnEndpointTable row creation is to GET the value of this object, and then to SET the object with the same value. If the SET operation succeeds, the manager can use this value as an index to create a new row in this table." REFERENCE
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -