⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2239.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 4 页
字号:
               The value available(3) indicates that the link,               light, or loopback is normal.  The value               notAvailable(4) indicates link loss, low light, or               no loopback.               The value remoteFault(5) indicates that a fault               has been detected at the remote end of the link.               This value applies to 10BASE-FB, 100BASE-T4 Far               End Fault Indication and non-specified remote               faults from a system running auto-negotiation.               The values remoteJabber(7), remoteLinkLoss(8), and               remoteTest(9) should be used instead of               remoteFault(5) where the reason for remote fault               is identified in the remote signaling protocol.               The value invalidSignal(6) indicates that an               invalid signal has been received from the other               end of the link.  InvalidSignal(6) applies only to               MAUs of type 10BASE-FB.               Where an IEEE Std 802.3u-1995 clause 22 MII is               present, a logic one in the remote fault bit               (reference section 22.2.4.2.8 of that document)               maps to the value remoteFault(5), and a logic zero               in the link status bit (reference section               22.2.4.2.10 of that document) maps to the value               notAvailable(4).  The value notAvailable(4) takes               precedence over the value remoteFault(5)."       REFERENCE               "[IEEE 802.3 Mgt], 30.5.1.1.4, aMediaAvailable."       ::= { ifMauEntry 5 }   ifMauMediaAvailableStateExits OBJECT-TYPE       SYNTAX     Counter32       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "A count of the number of times that               ifMauMediaAvailable for this MAU instance leaves               the state available(3)."       REFERENCE               "[IEEE 802.3 Mgt], 30.5.1.1.5, aLoseMediaCounter."       ::= { ifMauEntry 6 }   ifMauJabberState OBJECT-TYPE       SYNTAX     INTEGER {                      other(1),                      unknown(2),                      noJabber(3),                      jabbering(4)                  }       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The value other(1) is returned if the jabber               state is not 2, 3, or 4.  The agent must always               return other(1) for MAU type dot3MauTypeAUI.               The value unknown(2) is returned when the MAU's               true state is unknown; for example, when it is               being initialized.               If the MAU is not jabbering the agent returns               noJabber(3).  This is the 'normal' state.               If the MAU is in jabber state the agent returns               the jabbering(4) value."       REFERENCE               "[IEEE 802.3 Mgt], 30.5.1.1.6,               aJabber.jabberFlag."       ::= { ifMauEntry 7 }   ifMauJabberingStateEnters OBJECT-TYPE       SYNTAX     Counter32       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "A count of the number of times that               mauJabberState for this MAU instance enters the               state jabbering(4).  For MAUs of type               dot3MauTypeAUI, dot3MauType100BaseT4,               dot3MauType100BaseTX, and dot3MauType100BaseFX,               this counter will always indicate zero."       REFERENCE               "[IEEE 802.3 Mgt], 30.5.1.1.6,               aJabber.jabberCounter."       ::= { ifMauEntry 8 }   ifMauFalseCarriers OBJECT-TYPE       SYNTAX     Counter32       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "A count of the number of false carrier events               during IDLE in 100BASE-X links.  This counter does               not increment at the symbol rate.  It can               increment after a valid carrier completion at a               maximum rate of once per 100 ms until the next               carrier event.               This counter increments only for MAUs of type               dot3MauType100BaseT4, dot3MauType100BaseTX, and               dot3MauType100BaseFX.  For all other MAU types,               this counter will always indicate zero.               The approximate minimum time for rollover of this               counter is 7.4 hours."       REFERENCE               "[IEEE 802.3 Mgt], 30.5.1.1.10, aFalseCarriers."       ::= { ifMauEntry 9 }   ifMauTypeList OBJECT-TYPE       SYNTAX     Integer32       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "A value that uniquely identifies the set of               possible IEEE 802.3 types that the MAU could be.               The value is a sum which initially takes the value               zero.  Then, for each type capability of this MAU,               2 raised to the power noted below is added to the               sum. For example, a MAU which has the capability               to be only 10BASE-T would have a value of 512               (2**9).  In contrast, a MAU which supports both               10Base-T (full duplex) and 100BASE-TX (full               duplex) would have a value of ((2**11) + (2**16))               or 67584.               The powers of 2 assigned to the capabilities are               these:               Power  Capability                 0      other or unknown                 1      AUI                 2      10BASE-5                 3      FOIRL                 4      10BASE-2                 5      10BASE-T duplex mode unknown                 6      10BASE-FP                 7      10BASE-FB                 8      10BASE-FL duplex mode unknown                 9      10BROAD36                10      10BASE-T  half duplex mode                11      10BASE-T  full duplex mode                12      10BASE-FL half duplex mode                13      10BASE-FL full duplex mode                14      100BASE-T4                15      100BASE-TX half duplex mode                16      100BASE-TX full duplex mode                17      100BASE-FX half duplex mode                18      100BASE-FX full duplex mode                19      100BASE-T2 half duplex mode                20      100BASE-T2 full duplex mode               If auto-negotiation is present on this MAU, this               object will map to ifMauAutoNegCapability."       ::= { ifMauEntry 10 }   ifMauDefaultType OBJECT-TYPE       SYNTAX     OBJECT IDENTIFIER       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "This object identifies the default administrative               10 or 100 Mb/s baseband MAU type, to be used in               conjunction with the operational MAU type denoted               by ifMauType.               The set of possible values for this object is the               same as the set defined for the ifMauType object.               This object represents the administratively-               configured type of the MAU.  If auto-negotiation               is not enabled or is not implemented for this MAU,               the value of this object determines the               operational type of the MAU.  In this case, a set               to this object will force the MAU into the               specified operating mode.               If auto-negotiation is implemented and enabled for               this MAU, the operational type of the MAU is               determined by auto-negotiation, and the value of               this object denotes the type to which the MAU will               automatically revert if/when auto-negotiation is               later disabled.               NOTE TO IMPLEMENTORS:  It may be necessary to               provide for underlying hardware implementations               which do not follow the exact behavior specified               above.  In particular, when               ifMauAutoNegAdminStatus transitions from enabled               to disabled, the agent implementation must ensure               that the operational type of the MAU (as reported               by ifMauType) correctly transitions to the value               specified by this object, rather than continuing               to operate at the value earlier determined by the               auto-negotiation function."       REFERENCE               "[IEEE 802.3 Mgt], 30.5.1.1.1, aMAUID, and [IEEE               802.3 Std], 22.2.4.1.4."       ::= { ifMauEntry 11 }   ifMauAutoNegSupported OBJECT-TYPE       SYNTAX     TruthValue       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "This object indicates whether or not auto-               negotiation is supported on this MAU."       ::= { ifMauEntry 12 }   -- The ifJackTable applies to MAUs attached to interfaces   -- which have one or more external jacks (connectors).   ifJackTable OBJECT-TYPE       SYNTAX     SEQUENCE OF IfJackEntry       MAX-ACCESS not-accessible       STATUS     current       DESCRIPTION               "Information about the external jacks attached to               MAUs attached to an interface."       ::= { dot3IfMauBasicGroup 2 }   ifJackEntry OBJECT-TYPE       SYNTAX     IfJackEntry       MAX-ACCESS not-accessible       STATUS     current       DESCRIPTION               "An entry in the table, containing information               about a particular jack."       INDEX    { ifMauIfIndex,                  ifMauIndex,                  ifJackIndex }       ::= { ifJackTable 1 }   IfJackEntry ::=       SEQUENCE {           ifJackIndex               Integer32,           ifJackType               JackType       }   ifJackIndex OBJECT-TYPE       SYNTAX     Integer32 (1..2147483647)       MAX-ACCESS not-accessible       STATUS     current       DESCRIPTION               "This variable uniquely identifies the jack               described by this entry from among other jacks               attached to the same MAU."       ::= { ifJackEntry 1 }   ifJackType OBJECT-TYPE       SYNTAX     JackType       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "The jack connector type, as it appears on the               outside of the system."       ::= { ifJackEntry 2 }   -- The ifMauAutoNegTable applies to systems in which   -- auto-negotiation is supported on one or more MAUs   -- attached to interfaces.  Note that if auto-negotiation   -- is present and enabled, the ifMauType object reflects   -- the result of the auto-negotiation function.   ifMauAutoNegTable OBJECT-TYPE       SYNTAX     SEQUENCE OF IfMauAutoNegEntry       MAX-ACCESS not-accessible       STATUS     current       DESCRIPTION               "Configuration and status objects for the auto-               negotiation function of MAUs attached to               interfaces."       ::= { dot3IfMauAutoNegGroup 1 }   ifMauAutoNegEntry OBJECT-TYPE       SYNTAX     IfMauAutoNegEntry       MAX-ACCESS not-accessible       STATUS     current       DESCRIPTION               "An entry in the table, containing configuration               and status information for the auto-negotiation               function of a particular MAU."           INDEX     { ifMauIfIndex, ifMauIndex }       ::= { ifMauAutoNegTable 1 }   IfMauAutoNegEntry ::=       SEQUENCE {           ifMauAutoNegAdminStatus               INTEGER,           ifMauAutoNegRemoteSignaling               INTEGER,           ifMauAutoNegConfig               INTEGER,           ifMauAutoNegCapability               Integer32,           ifMauAutoNegCapAdvertised               Integer32,           ifMauAutoNegCapReceived               Integer32,           ifMauAutoNegRestart               INTEGER       }   ifMauAutoNegAdminStatus OBJECT-TYPE       SYNTAX     INTEGER {                      enabled(1),                      disabled(2)                  }       MAX-ACCESS read-write       STATUS     current       DESCRIPTION               "Setting this object to enabled(1) will cause the               interface which has the auto-negotiation signaling               ability to be enabled.               If the value of this object is disabled(2) then               the interface will act as it would if it had no               auto-negotiation signaling.  Under these               conditions, an IEEE 802.3 MAU will immediately be               forced to the state indicated by the value of the               object ifMauDefaultType.               NOTE TO IMPLEMENTORS:  When               ifMauAutoNegAdminStatus transitions from enabled               to disabled, the agent implementation must ensure               that the operational type of the MAU (as reported               by ifMauType) correctly transitions to the value               specified by the ifMauDefaultType object, rather               than continuing to operate at the value earlier               determined by the auto-negotiation function."       REFERENCE               "[IEEE 802.3 Mgt], 30.6.1.1.2, aAutoNegAdminState               and 30.6.1.2.2, acAutoNegAdminControl."       ::= { ifMauAutoNegEntry 1 }   ifMauAutoNegRemoteSignaling OBJECT-TYPE       SYNTAX     INTEGER {                      detected(1),                      notdetected(2)                  }       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "A value indicating whether the remote end of the               link is using auto-negotiation signaling. It takes               the value detected(1) if and only if, during the               previous link negotiation, FLP Bursts were               received."       REFERENCE               "[IEEE 802.3 Mgt], 30.6.1.1.3,               aAutoNegRemoteSignaling."       ::= { ifMauAutoNegEntry 2 }   ifMauAutoNegConfig OBJECT-TYPE       SYNTAX     INTEGER {                      other(1),                      configuring(2),                      complete(3),                      disabled(4),                      parallelDetectFail(5)                  }       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "A value indicating the current status of the               auto-negotiation process.  The enumeration               parallelDetectFail(5) maps to a failure in               parallel detection as defined in 28.2.3.1 of [IEEE               802.3 Std]."       REFERENCE               "[IEEE 802.3 Mgt], 30.6.1.1.4,               aAutoNegAutoConfig."       ::= { ifMauAutoNegEntry 4 }   ifMauAutoNegCapability OBJECT-TYPE       SYNTAX     Integer32       MAX-ACCESS read-only       STATUS     current       DESCRIPTION               "A value that uniquely identifies the set of               capabilities of the local auto-negotiation entity.               The value is a sum which initially takes the value               zero.  Then, for each capability of this               interface, 2 raised to the power noted below is               added to the sum. For example, an interface which               has the capability to support only 100Base-TX half               duplex would have a value of 32768 (2**15).  In               contrast, an interface which supports both               100Base-TX half duplex and and 100Base-TX full               duplex would have a value of 98304 ((2**15) +               (2**16)).               The powers of 2 assigned to the capabilities are               these:               Power   Capability                 0       other or unknown                (1-9)    (reserved)                10       10BASE-T  half duplex mode                11       10BASE-T  full duplex mode                12       (reserved)                13       (reserved)                14       100BASE-T4                15       100BASE-TX half duplex mode                16       100BASE-TX full duplex mode                17       (reserved)

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -