⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1559.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
            ENABLED     SERVICE state and/or service functions are                        allowed.            DISABLED    SERVICE state and/or service functions are not                        allowed.            NOTE: These values are incremented by one compared to the            standard DECnet values in order to maintain compliance            with RFC 1155."        ::= { phivCircuitParametersEntry 8 }   phivCircuitExecCost OBJECT-TYPE        SYNTAX INTEGER (1..25)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the routing cost of the circuit.            Routing sends messages along the path between two nodes            having the smallest cost."        ::= { phivCircuitParametersEntry 9 }   phivCircuitExecHelloTimer OBJECT-TYPE        SYNTAX INTEGER (1..8191)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value determines the frequency of Routing Hello            messages sent to the adjacent node on the circuit."        ::= { phivCircuitParametersEntry 10 }   -- Circuit Counters Table   phivCircuitCountTable OBJECT-TYPE        SYNTAX SEQUENCE OF PhivCircuitCountEntry        ACCESS not-accessible        STATUS mandatory        DESCRIPTION            "Information about the counters associated with all            circuits currently known."        ::= { circuit 2 }          phivCircuitCountEntry OBJECT-TYPE        SYNTAX PhivCircuitCountEntry        ACCESS not-accessible        STATUS mandatory        DESCRIPTION            "Counter information about all circuits currently known"        INDEX     { phivCircuitIndex }        ::= { phivCircuitCountTable 1 }   PhivCircuitCountEntry ::=        SEQUENCE {            phivCircuitCountSecLastZeroed                PhivCounter,            phivCircuitCountTermPacketsRecd                PhivCounter,            phivCircuitCountOriginPackSent                PhivCounter,            phivCircuitCountTermCongLoss                PhivCounter,            phivCircuitCountCorruptLoss                PhivCounter,            phivCircuitCountTransitPksRecd                PhivCounter,            phivCircuitCountTransitPkSent                PhivCounter,            phivCircuitCountTransitCongestLoss                PhivCounter,            phivCircuitCountCircuitDown                PhivCounter,            phivCircuitCountInitFailure                PhivCounter,            phivCircuitCountAdjDown                PhivCounter,            phivCircuitCountPeakAdj                PhivCounter,            phivCircuitCountBytesRecd                PhivCounter,            phivCircuitCountBytesSent                PhivCounter,            phivCircuitCountDataBlocksRecd                PhivCounter,            phivCircuitCountDataBlocksSent                PhivCounter,            phivCircuitCountUsrBuffUnav                PhivCounter        }   phivCircuitCountSecLastZeroed  OBJECT-TYPE        SYNTAX PhivCounter (0..65535)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of seconds since the circuit counters for this            circuit were last zeroed."        ::= { phivCircuitCountEntry 1 }   phivCircuitCountTermPacketsRecd OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of terminating packets received on this circuit."        ::= { phivCircuitCountEntry 2 }   phivCircuitCountOriginPackSent OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of originating packets sent on this circuit."        ::= { phivCircuitCountEntry 3 }   phivCircuitCountTermCongLoss OBJECT-TYPE        SYNTAX PhivCounter (0..65535)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of terminating congestion losses on this            circuit."        ::= { phivCircuitCountEntry 4 }   phivCircuitCountCorruptLoss OBJECT-TYPE        SYNTAX PhivCounter (0..255)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of corruption losses on this circuit."        ::= { phivCircuitCountEntry 5 }   phivCircuitCountTransitPksRecd OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of Transit packets received on this circuit."        ::= { phivCircuitCountEntry 6 }   phivCircuitCountTransitPkSent OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of transit packets sent on this circuit."        ::= { phivCircuitCountEntry 7 }   phivCircuitCountTransitCongestLoss OBJECT-TYPE        SYNTAX PhivCounter (0..65535)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of transit congestion losses on this circuit."        ::= { phivCircuitCountEntry 8 }   phivCircuitCountCircuitDown OBJECT-TYPE        SYNTAX PhivCounter (0..255)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of circuit downs on this circuit."        ::= { phivCircuitCountEntry 9 }   phivCircuitCountInitFailure OBJECT-TYPE        SYNTAX PhivCounter (0..255)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of Initialization failures on this circuit."        ::= { phivCircuitCountEntry 10 }   phivCircuitCountAdjDown OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "This counter indicates the number of adjacency losses            that result from any of the following:                 Node listener timeout                 Invalid data received at node listener                 Unexpected control (initialization or verification)                     message received                 Routing message received with a checksum error                 Node identification from a routing message or a                 Hello message that is not the one expected Hello                 message received indicating that connectivity                 became one-way                 Adjacency idled."        ::= { phivCircuitCountEntry 11 }   phivCircuitCountPeakAdj OBJECT-TYPE        SYNTAX PhivCounter (0..65535)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "This counter indicates the maximum number of nodes            that are up on the circuit."        ::= { phivCircuitCountEntry 12 }   phivCircuitCountBytesRecd OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of bytes received on this circuit."        ::= { phivCircuitCountEntry 13 }   phivCircuitCountBytesSent OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of bytes sent on this circuit."        ::= { phivCircuitCountEntry 14 }   phivCircuitCountDataBlocksRecd OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of data blocks received on this circuit."        ::= { phivCircuitCountEntry 15 }   phivCircuitCountDataBlocksSent OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of data blocks sent on this circuit."        ::= { phivCircuitCountEntry 16 }   phivCircuitCountUsrBuffUnav OBJECT-TYPE        SYNTAX PhivCounter (0..65535)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of user buffer unavailable errors."        ::= { phivCircuitCountEntry 17 }   -- Additional Circuit Parameters   phivCircuitOrigQueueLimit OBJECT-TYPE        SYNTAX INTEGER        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This parameter indicates the maximum number of            originating packets that may be outstanding on this            circuit. This does not include route-thru traffic."        ::= { circuit 3 }   phivCircuitCountZeroCount OBJECT-TYPE        SYNTAX INTEGER {            other (1),            reset (2)        }        ACCESS read-write        STATUS mandatory        DESCRIPTION            "When this value is set to 2, all of the counters in the            Circuit Counter Table are set to zero."        ::= { circuit 4 }   -- DDCMP Circuit Group   -- The implementation of the DDCMP Circuit Group is optional.   -- A system can be said to implement this group if and only if   -- all objects in this group are implemented.   -- DDCMP Parameters Table   phivDDCMPCircuitParametersTable OBJECT-TYPE        SYNTAX SEQUENCE OF PhivDDCMPCircuitParametersEntry        ACCESS not-accessible        STATUS mandatory        DESCRIPTION            "Information about DDCMP circuit parameters."        ::= { ddcmp 1}   phivDDCMPCircuitParametersEntry OBJECT-TYPE        SYNTAX PhivDDCMPCircuitParametersEntry        ACCESS not-accessible        STATUS mandatory        DESCRIPTION            "Parameters information about DDCMP circuits currently             known."        INDEX     { phivDDCMPCircuitIndex }        ::= { phivDDCMPCircuitParametersTable 1 }   PhivDDCMPCircuitParametersEntry ::=        SEQUENCE {            phivDDCMPCircuitIndex                INTEGER,            phivDDCMPCircuitAdjNodeAddr                PhivAddr,            phivDDCMPCircuitTributary                INTEGER        }   phivDDCMPCircuitIndex OBJECT-TYPE        SYNTAX INTEGER (1..65535)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "A unique index value for each known DDCMP circuit.            This is the same value as phivCircuitIndex."        ::= { phivDDCMPCircuitParametersEntry 1 }   phivDDCMPCircuitAdjNodeAddr OBJECT-TYPE        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))        ACCESS read-only        STATUS mandatory        DESCRIPTION            "The address of the adjacent node."        ::= { phivDDCMPCircuitParametersEntry 2 }   phivDDCMPCircuitTributary OBJECT-TYPE        SYNTAX INTEGER (0..255)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "This value represents the Data Link physical tributary            address of the circuit."        ::= { phivDDCMPCircuitParametersEntry 3 }   -- DDCMP Circuit Counter Table   phivDDCMPCircuitCountTable OBJECT-TYPE        SYNTAX SEQUENCE OF PhivDDCMPCircuitCountEntry        ACCESS not-accessible        STATUS mandatory        DESCRIPTION            "Information about the DDCMP counters associated with all            circuits currently known."        ::= { ddcmp 2 }   phivDDCMPCircuitCountEntry OBJECT-TYPE        SYNTAX PhivDDCMPCircuitCountEntry        ACCESS not-accessible        STATUS mandatory        DESCRIPTION            "Counter information about DDCMP circuits now known"        INDEX     { phivCircuitIndex }        ::= { phivDDCMPCircuitCountTable 1 }   PhivDDCMPCircuitCountEntry ::=        SEQUENCE {            phivDDCMPCircuitErrorsInbd                PhivCounter,            phivDDCMPCircuitErrorsOutbd                PhivCounter,            phivDDCMPCircuitRmteReplyTimeouts                PhivCounter,            phivDDCMPCircuitLocalReplyTimeouts                PhivCounter,            phivDDCMPCircuitRmteBuffErrors                PhivCounter,            phivDDCMPCircuitLocalBuffErrors                PhivCounter,            phivDDCMPCircuitSelectIntervalsElap                PhivCounter,            phivDDCMPCircuitSelectTimeouts                INTEGER (0..255)        }   phivDDCMPCircuitErrorsInbd OBJECT-TYPE        SYNTAX PhivCounter (0..255)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of Data errors inbound."        ::= { phivDDCMPCircuitCountEntry 1 }   phivDDCMPCircuitErrorsOutbd OBJECT-TYPE        SYNTAX PhivCounter (0..255)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of outbound data errors."

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -