⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1559.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
        STATUS mandatory        DESCRIPTION            "Number of bytes received from the target host."        ::= { phivEndCountEntry 7 }   phivEndCountTotalBytesSent OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of bytes sent to the target host."        ::= { phivEndCountEntry 8 }   phivEndCountTotalMessRec OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of messages received from the target host."        ::= { phivEndCountEntry 9 }   phivEndCountTotalMessSent OBJECT-TYPE        SYNTAX PhivCounter (0..2147483647)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of messages sent to the target host."        ::= { phivEndCountEntry 10 }   phivEndCountConnectsRecd OBJECT-TYPE        SYNTAX PhivCounter (0..65535)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of connects received from the target host."        ::= { phivEndCountEntry 11 }   phivEndCountConnectsSent OBJECT-TYPE        SYNTAX PhivCounter (0..65535)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of connects sent to the target host."        ::= {phivEndCountEntry 12 }   phivEndCountReponseTimeouts OBJECT-TYPE        SYNTAX PhivCounter (0..65535)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of response timeouts."        ::= { phivEndCountEntry 13 }   phivEndCountRecdConnectResErrs OBJECT-TYPE        SYNTAX PhivCounter (0..65535)        ACCESS read-only        STATUS mandatory        DESCRIPTION            "Number of received connect resource errors."        ::= {phivEndCountEntry 14 }   -- additional End System objects   phivEndMaxLinks OBJECT-TYPE        SYNTAX INTEGER (1..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the maximum active logical            link count allowed for the executor."        ::= { end 3 }   phivEndNSPVers OBJECT-TYPE        SYNTAX DisplayString (SIZE (0..255))        ACCESS read-only        STATUS mandatory        DESCRIPTION            "This read-only parameter represents the version number            of the node End Communication S/W. The format is            version number, ECO, and user ECO, e.g., 4.1.0"        ::= { end 4 }   phivEndRetransmitFactor OBJECT-TYPE        SYNTAX INTEGER (1..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the maximum number of times the            source End Communication at the executor node will            restart the retransmission timer when it expires. If            the number is exceeded, Session Control disconnects the            logical link for the user."        ::= { end 5 }   phivEndDelayFact OBJECT-TYPE        SYNTAX INTEGER (1..255)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This is the number by which to multiply one sixteenth            of the estimated round trip delay to a node to set the            retransmission timer to that node."        ::= { end 6 }   phivEndDelayWeight OBJECT-TYPE        SYNTAX INTEGER (1..255)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This number represents the weight to apply to a            current round trip delay estimate to a remote node            when updating the estimated round trip delay to a node.            On some systems the number must be 1 less than a power            of 2 for computational efficiency."        ::= { end 7 }   phivEndInactivityTimer OBJECT-TYPE        SYNTAX INTEGER (1..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the maximum duration of inactivity            (no data in either direction) on a logical link before            the node checks to see if the logical link still works.            If no activity occurs within the minimum number of            seconds, End Communication generates artificial            traffic to test the link (End Communication            specification)."        ::= { end 8 }   phivEndCountZeroCount OBJECT-TYPE        SYNTAX INTEGER {            other (1),            reset (2)        }        ACCESS read-write        STATUS mandatory        DESCRIPTION            "When this value is set to 2, all of the counters in            the End System Counter Table are set to zero."        ::= { end 9 }   phivEndMaxLinksActive OBJECT-TYPE        SYNTAX PhivCounter (0..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the high water mark for the            number of links that were active at any one time."        ::= { end 10 }   -- Routing Layer Group   -- The implementation of the Routing Layer Group is mandatory for   -- all systems that implement level 1 routing layer   -- communications.   phivRouteBroadcastRouteTimer OBJECT-TYPE        SYNTAX INTEGER (1..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value determines the maximum time in seconds             allowed between Routing updates on Ethernet             circuits. When this timer expired before a routing             update occurs, a routing update is forced.  With a             standard calculation, Routing also uses this timer             to enforce a minimum delay between routing updates."        ::= { routing 1 }   phivRouteBuffSize OBJECT-TYPE        SYNTAX INTEGER (1..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This parameter value determines the maximum size of             a Routing message. It therefore determines the maximum             size message that can be forwarded.  This size includes             protocol overhead down to and including the End             Communication layer, plus a constant value of 6. (This             value of 6 is included to provide compatibility with             the parameter definition in Phase III, which included             the Routing overhead.) It does not include Routing or             Data link overhead (except for the constant value of             6). There is one buffer size for all circuits.             NOTE: The BUFFER SIZE defines the maximum size messages             that the Routing layer can forward. The SEGMENT BUFFER             SIZE (defined below) defines the maximum size messages             that the End Communication layer can transmit or             receive. The SEGMENT BUFFER SIZE is always less than             or equal to the BUFFER SIZE. Normally the two             parameters will be equal. They may be different to             allow the network manager to alter buffer sizes             on all nodes without interruption of service. They both             include an extra 6 bytes for compatibility with Phase             III."        ::= { routing 2 }   phivRouteRoutingVers OBJECT-TYPE        SYNTAX DisplayString (SIZE (0..255))        ACCESS read-only        STATUS mandatory        DESCRIPTION            "This read-only parameter identifies the executor node's            Routing version number.  The format is version number,            ECO, and user ECO, e.g., 4.1.0"        ::= { routing 3 }   phivRouteMaxAddr OBJECT-TYPE        SYNTAX INTEGER (1..1023)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the largest node number and,            therefore, number of nodes that can be known about            by the executor node's home area."        ::= { routing 4 }   phivRouteMaxBdcastNonRouters OBJECT-TYPE        SYNTAX INTEGER (0..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the maximum total number of            nonrouters the executor node can have on its Ethernet            circuits."        ::= { routing 5 }   phivRouteMaxBdcastRouters OBJECT-TYPE        SYNTAX INTEGER (0..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the maximum total number of            routers the executor node can have on its Ethernet            circuits."        ::= { routing 6 }   phivRouteMaxBuffs OBJECT-TYPE        SYNTAX INTEGER (1..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the maximum number of transmit            buffers that Routing may use for all circuits."        ::= { routing 7 }   phivRouteMaxCircuits OBJECT-TYPE        SYNTAX INTEGER (1..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the maximum number of Routing            circuits that the executor node can know about."        ::= { routing 8 }   phivRouteMaxCost OBJECT-TYPE        SYNTAX INTEGER (1..1022)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the maximum total path cost            allowed from the executor to any node within an area.            The path cost is the sum of the circuit costs along            a path between two nodes. This parameter defines the            point where the executor node's Routing routing            decision algorithm declares another node unreachable            because the cost of the least costly path to the            other node is excessive. For correct operation, this            parameter must not be less than the maximum path cost            of the network."        ::= { routing 9 }   phivRouteMaxHops OBJECT-TYPE        SYNTAX INTEGER (1..30)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the maximum number of routing hops            allowable from the executor to any other reachable node            within an area. (A hop is the logical distance over a            circuit between two adjacent nodes.) This parameter            defines the point where the executor node's Routing            routing decision algorithm declares another node            unreachable because the length of the shortest path            between the two nodes is too long. For correct            operation, this parameter must not be less than the            network diameter. (The network diameter is the            reachability distance between the two nodes of the            network having the greatest reachability distance,            where reachability distance is the length the shortest            path between a given pair of nodes.)"        ::= { routing 10 }   phivRouteMaxVisits OBJECT-TYPE        SYNTAX INTEGER (1..63)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value represents the maximum number of nodes a            message coming into the executor node can have visited.            If the message is not for this node and the MAXIMUM            VISITS number is exceeded, the message is discarded.            The MAXIMUM VISITS parameter defines the point where            the packet lifetime control algorithm discards            a packet that has traversed too many nodes. For correct            operation, this parameter must not be less than the            maximum path length of the network. (The maximum path            length is the routing distance between the two nodes of            the network having the greatest routing distance, where            routing distance is the length of the least costly            path between a given pair of nodes.)"        ::= { routing 11 }   phivRouteRoutingTimer OBJECT-TYPE        SYNTAX INTEGER (1..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This value determines the maximum time in seconds            allowed between Routing updates on non-Ethernet            circuits. When this timer expires before a routing            update occurs, a routing update is forced."        ::= { routing 12 }   phivRouteSegBuffSize OBJECT-TYPE        SYNTAX INTEGER (1..65535)        ACCESS read-write        STATUS mandatory        DESCRIPTION            "This parameter value determines the maximum size of an            end-to-end segment. The size is a decimal integer in            the range 1-65535. This size is in bytes. This size            includes protocol overhead down to and including the            End Communication layer, plus a constant value of 6.            (This value of 6 is included to provide compatibility            with the BUFFER SIZE parameter definition.) It does not            include Routing or Data link overhead (except for the            constant value of 6)."        ::= { routing 13 }   phivRouteType OBJECT-TYPE        SYNTAX INTEGER {            routing-III (1),            nonrouting-III (2),            area (3),            routing-IV (4),            nonrouting-IV (5)        }        ACCESS read-only        STATUS obsolete        DESCRIPTION            "This parameter indicates the type of the executor            node. The node-type is one of the following:            routing-III            nonrouting-III            routing-IV            ronrouting-IV            area            A routing node has full routing capability. A            nonrouting node contains a subset of the Routing            routing modules. The III and IV indicate the DNA            phase of the node. Nonrouting nodes can deliver            and receive packets to and from any node, but cannot            route packets from other nodes through to other nodes.            An area node routes between areas. Refer to the Routing            specification for details.            For adjacent nodes, this is a read-only parameter that            indicates the type of the reachable adjacent node.            NOTE: The ROUTING-III and NONROUTING-III values are            incremented by one compared to the standard DECnet            values in order to maintain compliance with RFC 1155)"        ::= { routing 14 }   phivRouteCountAgedPktLoss OBJECT-TYPE        SYNTAX PhivCounter (0..127)

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -