⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1289.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
           DESCRIPTION               "This value represents the Data Link physical tributary               address of the circuit."           ::= { phivDDCMPCircuitParametersEntry 3 }       -- DDCMP Circuit Counter Table       phivDDCMPCircuitCountTable OBJECT-TYPE           SYNTAX SEQUENCE OF PhivDDCMPCircuitCountEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "Information about the DDCMP counters associated with all               circuits currently known."           ::= { ddcmp 2 }       phivDDCMPCircuitCountEntry OBJECT-TYPE           SYNTAX PhivDDCMPCircuitCountEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "Counter information about DDCMP circuits now known"           INDEX     { phivCircuitIndex }           ::= { phivDDCMPCircuitCountTable 1 }       PhivDDCMPCircuitCountEntry ::=           SEQUENCE {               phivDDCMPCircuitErrorsInbd                   PhivCounter (0..255),               phivDDCMPCircuitErrorsOutbd                   PhivCounter (0..255),               phivDDCMPCircuitRmteReplyTimeouts                   PhivCounter (0..255),               phivDDCMPCircuitLocalReplyTimeouts                   PhivCounter (0..255),               phivDDCMPCircuitRmteBuffErrors                   PhivCounter (0..255),               phivDDCMPCircuitLocalBuffErrors                   PhivCounter (0..255),               phivDDCMPCircuitSelectIntervalsElap                   PhivCounter (0..65535),               phivDDCMPCircuitSelectTimeouts                   PhivCounter (0..255)           }       phivDDCMPCircuitErrorsInbd OBJECT-TYPE           SYNTAX PhivCounter (0..255)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Number of Data errors inbound."           ::= { phivDDCMPCircuitCountEntry 1 }       phivDDCMPCircuitErrorsOutbd OBJECT-TYPE           SYNTAX PhivCounter (0..255)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Number of outbound data errors."           ::= { phivDDCMPCircuitCountEntry 2 }       phivDDCMPCircuitRmteReplyTimeouts OBJECT-TYPE           SYNTAX PhivCounter (0..255)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Number of remote reply timeouts."           ::= { phivDDCMPCircuitCountEntry 3 }       phivDDCMPCircuitLocalReplyTimeouts OBJECT-TYPE           SYNTAX PhivCounter (0..255)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Number of local Reply timeouts."           ::= { phivDDCMPCircuitCountEntry 4 }       phivDDCMPCircuitRmteBuffErrors OBJECT-TYPE           SYNTAX PhivCounter (0..255)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Number of remote reply time out errors."           ::= { phivDDCMPCircuitCountEntry 5 }       phivDDCMPCircuitLocalBuffErrors  OBJECT-TYPE           SYNTAX PhivCounter (0..255)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Number of local buffer errors."           ::= { phivDDCMPCircuitCountEntry 6 }       phivDDCMPCircuitSelectIntervalsElap OBJECT-TYPE           SYNTAX PhivCounter (0..65535)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Selection intervals that have elapsed."           ::= {phivDDCMPCircuitCountEntry 7 }       phivDDCMPCircuitSelectTimeouts OBJECT-TYPE           SYNTAX PhivCounter (0..255)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Number of selection timeouts."           ::= {phivDDCMPCircuitCountEntry 8 }       -- DDCMP Line Count Table       phivDDCMPLineCountTable OBJECT-TYPE           SYNTAX SEQUENCE OF PhivDDCMPLineCountEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "The DDCMP Line Count Table."           ::= { ddcmp 3 }       phivDDCMPLineCountEntry OBJECT-TYPE           SYNTAX PhivDDCMPLineCountEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "There is one entry in the table for each line."           INDEX  { phivDDCMPLineCountIndex }           ::= { phivDDCMPLineCountTable 1 }       PhivDDCMPLineCountEntry ::=           SEQUENCE {               phivDDCMPLineCountIndex                   INTEGER,               phivDDCMPLineCountDataErrsIn                   PhivCounter (0..255),               phivDDCMPLineCountRmteStationErrs                   PhivCounter (0..255),               phivDDCMPLineCountLocalStationErrs                   PhivCounter (0..255)           }       phivDDCMPLineCountIndex OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-only           STATUS mandatory           DESCRIPTION               "The line on which this entry's equivalence is               effective. The interface identified by a particular               value of this index is the same interface as               identified by the same value of phivLineIndex.               This value is the IfIndex."           ::= { phivDDCMPLineCountEntry 1 }       phivDDCMPLineCountDataErrsIn OBJECT-TYPE           SYNTAX PhivCounter ( 0..255 )           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Number of data errors inbound."           ::= { phivDDCMPLineCountEntry 2 }       phivDDCMPLineCountRmteStationErrs OBJECT-TYPE           SYNTAX PhivCounter ( 0..255 )           ACCESS read-only           STATUS mandatory           DESCRIPTION               "Number of remote station errors."           ::= { phivDDCMPLineCountEntry 3 }       phivDDCMPLineCountLocalStationErrs OBJECT-TYPE           SYNTAX PhivCounter ( 0..255 )           ACCESS read-only           STATUS mandatory           DESCRIPTION                "Number of local station errors."           ::= { phivDDCMPLineCountEntry 4 }       -- DDCMP Multipoint Circuit Control Group       -- The implementation of the DDCMP Multipoint Circuit Control       -- Group is mandatory for all systems which support DDCMP       -- multipoint control circuits.       phivControlSchedTimer OBJECT-TYPE           SYNTAX INTEGER (50..65535)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "This value represents the number of milliseconds               between recalculation of tributary polling priorities."           DEFVAL { 200 }           ::= { control 1 }       phivControlDeadTimer OBJECT-TYPE           SYNTAX INTEGER (1..65535)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "This value represents the number of milliseconds               between polls of one of the set of dead               tributaries."           DEFVAL { 10000 }           ::= { control 2 }       phivControlDelayTimer OBJECT-TYPE           SYNTAX INTEGER (1..65535)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "This value represents the minimum number of               milliseconds to delay between polls. The delay timer               limits the effect of a very fast control station on               slow tributaries."           ::= { control 3 }       phivControlStreamTimer OBJECT-TYPE           SYNTAX INTEGER (0..65535)           ACCESS read-only           STATUS mandatory           DESCRIPTION               "This value represents the number of milliseconds a               tributary or a half duplex remote station is               allowed to hold the line.               NOTE: This parameter can also be applied to               half-duplex lines of type DDCMP POINT."           DEFVAL { 6000 }           ::= { control 4 }       -- DDCMP Multipoint Circuit Control Parameters Table       phivControlParametersTable OBJECT-TYPE           SYNTAX SEQUENCE OF PhivControlParametersEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "Information about control circuit parameters."           ::= { control 5 }       phivControlParametersEntry OBJECT-TYPE           SYNTAX PhivControlParametersEntry           ACCESS not-accessible           STATUS mandatory           DESCRIPTION               "Parameters information about control circuits               currently known."           INDEX  { phivControlCircuitIndex }           ::= { phivControlParametersTable 1 }       PhivControlParametersEntry ::=           SEQUENCE {               phivControlCircuitIndex                   INTEGER,               phivControlBabbleTimer                   INTEGER (1..65535),               phivControlMaxBuffs                   INTEGER (0..254),               phivControlMaxTransmits                   INTEGER (1..255),               phivControlDyingBase                   INTEGER (0..255),               phivControlDyingIncrement                   INTEGER (0..255),               phivControlDeadThreshold                   INTEGER (0..255),               phivControlDyingThreshold                   INTEGER (0..255),               phivControlInactTreshold                   INTEGER (0..255),               phivControlPollingState                   INTEGER,               phivControlPollingSubState                   INTEGER,               phivControlTransTimer                   INTEGER (0..65535)           }       phivControlCircuitIndex OBJECT-TYPE           SYNTAX INTEGER           ACCESS read-only           STATUS mandatory           DESCRIPTION               "A unique index value for each known multirpoint               control circuit.                This is the same value as phivCircuitIndex."           ::= { phivControlParametersEntry 1 }       phivControlBabbleTimer OBJECT-TYPE           SYNTAX INTEGER (1..65535)           ACCESS read-write           STATUS mandatory           DESCRIPTION               "This value represents the number of milliseconds that a               selected tributary or remote half-duplex station is               allowed to transmit."           DEFVAL { 6000 }           ::= { phivControlParametersEntry 2 }       phivControlMaxBuffs  OBJECT-TYPE           SYNTAX INTEGER (0..254)           ACCESS read-write           STATUS mandatory           DESCRIPTION               "This value represents the maximum number of buffers the               tributary can use from a common buffer pool. If not               set, there is no common buffer pool and buffers are               explicitly supplied by the higher level. Count is a               decimal integer in the range 1-254."           ::= { phivControlParametersEntry 3 }       phivControlMaxTransmits  OBJECT-TYPE           SYNTAX INTEGER (1..255)           ACCESS read-write           STATUS mandatory           DESCRIPTION               "This value represents the maximum number of data               messages that can be transmitted at one time. Count               is a decimal integer in the range 1-255."           DEFVAL { 4 }           ::= { phivControlParametersEntry 4 }       phivControlDyingBase OBJECT-TYPE           SYNTAX INTEGER (0..255)           ACCESS read-write           STATUS mandatory           DESCRIPTION               "This value represents the base priority to which a               tributary is reset each time it has been polled. A               separate base can be set for each of the indicated               polling states. Base is a decimal integer in the range               0-255.  If not set, the defaults are: active, 255;               inactive, 0; and dying, 0."           ::= { phivControlParametersEntry 5 }       phivControlDyingIncrement OBJECT-TYPE           SYNTAX INTEGER (0..255)           ACCESS read-write           STATUS mandatory           DESCRIPTION               "This value represents the increment added to the               tributary priority each time the scheduling timer               expires.  If not set, the defaults are: active, 0;               inactive, 64; and dying, 16."           ::= { phivControlParametersEntry 6 }       phivControlDeadThreshold OBJECT-TYPE           SYNTAX INTEGER (0..255)           ACCESS read-write           STATUS mandatory           DESCRIPTION               "This value represents the number of times to poll the               active, inactive, or dying tributary before changing               its polling 

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -