📄 rfc1289.mib
字号:
"Number of user bytes sent to the target host." ::= { phivEndCountEntry 4 } phivEndUCountUsrMessRec OBJECT-TYPE SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "Number of user messages received from the target host." ::= { phivEndCountEntry 5 } phivEndCountUsrMessSent OBJECT-TYPE SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "Number of user messages sent to the target host." ::= { phivEndCountEntry 6 } phivEndCountTotalBytesRec OBJECT-TYPE SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes received from the target host." ::= { phivEndCountEntry 7 } phivEndCountTotalBytesSent OBJECT-TYPE SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes sent to the target host." ::= { phivEndCountEntry 8 } phivEndCountTotalMessRec OBJECT-TYPE SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "Number of messages received from the target host." ::= { phivEndCountEntry 9 } phivEndCountTotalMessSent OBJECT-TYPE SYNTAX PhivCounter ACCESS read-only STATUS mandatory DESCRIPTION "Number of messages sent to the target host." ::= { phivEndCountEntry 10 } phivEndCountConnectsRecd OBJECT-TYPE SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Number of connects received from the target host." ::= { phivEndCountEntry 11 } phivEndCountConnectsSent OBJECT-TYPE SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Number of connects sent to the target host." ::= {phivEndCountEntry 12 } phivEndCountReponseTimeouts OBJECT-TYPE SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Number of response timeouts." ::= { phivEndCountEntry 13 } phivEndCountRecdConnectResErrs OBJECT-TYPE SYNTAX PhivCounter (0..65535) ACCESS read-only STATUS mandatory DESCRIPTION "Number of received connect resource errors." ::= {phivEndCountEntry 14 } -- additional End System objects phivEndMaxLinks OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum active logical link count allowed for the executor." ::= { end 3 } phivEndNSPVers OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255) ) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter represents the version number of the node End Communication S/W. The format is version number, ECO, and user ECO, e.g., 4.1.0" ::= { end 4 } phivEndRetransmitFactor OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of times the source End Communication at the executor node will restart the retransmission timer when it expires. If the number is exceeded, Session Control disconnects the logical link for the user." ::= { end 5 } phivEndDelayFact OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This is the number by which to multiply one sixteenth of the estimated round trip delay to a node to set the retransmission timer to that node." ::= { end 6 } phivEndDelayWeight OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This number represents the weight to apply to a current round trip delay estimate to a remote node when updating the estimated round trip delay to a node. On some systems the number must be 1 less than a power of 2 for computational efficiency." ::= { end 7 } phivEndInactivityTimer OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum duration of inactivity (no data in either direction) on a logical link before the node checks to see if the logical link still works. If no activity occurs within the minimum number of seconds, End Communication generates artificial traffic to test the link (End Communication specification)." ::= { end 8 } phivEndCountZeroCount OBJECT-TYPE SYNTAX INTEGER { other (1), reset (2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this value is set to 2, all of the counters in the End System Counter Table are set to zero." ::= { end 9 } phivEndMaxLinksActive OBJECT-TYPE SYNTAX PhivCounter (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the high water mark for the number of links that were active at any one time." ::= { end 10 } -- Routing Layer Group -- The implementation of the Routing Layer Group is mandatory for -- all systems that implement level 1 routing layer -- communications. phivRouteBroadcastRouteTimer OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value determines the maximum time in seconds allowed between Routing updates on Ethernet circuits. When this timer expired before a routing update occurs, a routing update is forced. With a standard calculation, Routing also uses this timer to enforce a minimum delay between routing updates." ::= { routing 1 } phivRouteBuffSize OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter value determines the maximum size of a Routing message. It therefore determines the maximum size message that can be forwarded. This size includes protocol overhead down to and including the End Communication layer, plus a constant value of 6. (This value of 6 is included to provide compatibility with the parameter definition in Phase III, which included the Routing overhead.) It does not include Routing or Data link overhead (except for the constant value of 6). There is one buffer size for all circuits. NOTE: The BUFFER SIZE defines the maximum size messages that the Routing layer can forward. The SEGMENT BUFFER SIZE (defined below) defines the maximum size messages that the End Communication layer can transmit or receive. The SEGMENT BUFFER SIZE is always less than or equal to the BUFFER SIZE. Normally the two parameters will be equal. They may be different to allow the network manager to alter buffer sizes on all nodes without interruption of service. They both include an extra 6 bytes for compatibility with Phase III." ::= { routing 2 } phivRouteRoutingVers OBJECT-TYPE SYNTAX DisplayString ( SIZE (0..255) ) ACCESS read-only STATUS mandatory DESCRIPTION "This read-only parameter identifies the executor node's Routing version number. The format is version number, ECO, and user ECO, e.g., 4.1.0" ::= { routing 3 } phivRouteMaxAddr OBJECT-TYPE SYNTAX INTEGER (1..1023) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the largest node number and, therefore, number of nodes that can be known about by the executor node's home area." ::= { routing 4 } phivRouteMaxBdcastNonRouters OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum total number of nonrouters the executor node can have on its Ethernet circuits." ::= { routing 5 } phivRouteMaxBdcastRouters OBJECT-TYPE SYNTAX INTEGER (0..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum total number of routers the executor node can have on its Ethernet circuits." ::= { routing 6 } phivRouteMaxBuffs OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of transmit buffers that Routing may use for all circuits." ::= { routing 7 } phivRouteMaxCircuits OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of Routing circuits that the executor node can know about." ::= { routing 8 } phivRouteMaxCost OBJECT-TYPE SYNTAX INTEGER (1..1022) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum total path cost allowed from the executor to any node within an area. The path cost is the sum of the circuit costs along a path between two nodes. This parameter defines the point where the executor node's Routing routing decision algorithm declares another node unreachable because the cost of the least costly path to the other node is excessive. For correct operation, this parameter must not be less than the maximum path cost of the network." ::= { routing 9 } phivRouteMaxHops OBJECT-TYPE SYNTAX INTEGER (1..30) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of routing hops allowable from the executor to any other reachable node within an area. (A hop is the logical distance over a circuit between two adjacent nodes.) This parameter defines the point where the executor node's Routing routing decision algorithm declares another node unreachable because the length of the shortest path between the two nodes is too long. For correct operation, this parameter must not be less than the network diameter. (The network diameter is the reachability distance between the two nodes of the network having the greatest reachability distance, where reachability distance is the length the shortest path between a given pair of nodes.)" ::= { routing 10 } phivRouteMaxVisits OBJECT-TYPE SYNTAX INTEGER (1..63) ACCESS read-write STATUS mandatory DESCRIPTION "This value represents the maximum number of nodes a message coming into the executor node can have visited. If the message is not for this node and the MAXIMUM VISITS number is exceeded, the message is discarded. The MAXIMUM VISITS parameter defines the point where the packet lifetime control algorithm discards a packet that has traversed too many nodes. For correct operation, this parameter must not be less than the maximum path length of the network. (The maximum path length is the routing distance between the two nodes of the network having the greatest routing distance, where routing distance is the length of the least costly path between a given pair of nodes.)" ::= { routing 11 } phivRouteRoutingTimer OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This value determines the maximum time in seconds allowed between Routing updates on non-Ethernet circuits. When this timer expires before a routing update occurs, a routing update is forced." ::= { routing 12 } phivRouteSegBuffSize OBJECT-TYPE SYNTAX INTEGER
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -