⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1747.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
                    STATUS      current                    DESCRIPTION                        "This object defines the number of times the                        active poll list will be traversed before                        polling a station on the slow poll list for a                        primary, multipoint SDLC port.  Depending  on                        the implementation, a write operation to this                        administered value  may not take effect until                        the port is cycled inactive.                        This object only has meaning for SDLC ports                        where                            sdlcPortAdminRole == primary                        and                            sdlcPortAdminTopology == multipoint "                    DEFVAL { 20 }                    ::= { sdlcPortAdminEntry 8 }sdlcPortAdminSlowPollTimer OBJECT-TYPE                    SYNTAX      TimeInterval                    MAX-ACCESS  read-write                    STATUS      current                    DESCRIPTION                        "This object describes the elapsed time (in                        1/100ths of a second) between polls for failed                        secondary link station addresses.  Depending                        on the implementation, a write operation to                        this administered value  may not take effect                        until the port is cycled inactive.                        This object only has meaning for SDLC ports                        where                            sdlcPortAdminRole == primary                        and                            sdlcPortAdminTopology == multipoint "                    DEFVAL { 2000 }                    ::= { sdlcPortAdminEntry 9 }--  *************************************************************--  *                                                           *--  *                THE SDLC PORT OPERATIONAL TABLE            *--  *                                                           *--  *************************************************************sdlcPortOperTable   OBJECT-TYPE                    SYNTAX      SEQUENCE OF SdlcPortOperEntry                    MAX-ACCESS  not-accessible                    STATUS      current                    DESCRIPTION                        "This table contains current SDLC port                        parameters.  Many of these objects have                        corresponding objects inthe sdlcPortAdminTable."                    ::= { sdlcPortGroup 2 }sdlcPortOperEntry   OBJECT-TYPE                    SYNTAX      SdlcPortOperEntry                    MAX-ACCESS  not-accessible                    STATUS      current                    DESCRIPTION                        "Currently set parameters for a specific SDLC                        port."                    INDEX   { ifIndex }                    ::= { sdlcPortOperTable 1 }SdlcPortOperEntry   ::= SEQUENCE{        sdlcPortOperName                DisplayString,        sdlcPortOperRole                INTEGER,        sdlcPortOperType                INTEGER,        sdlcPortOperTopology            INTEGER,        sdlcPortOperISTATUS             INTEGER,        sdlcPortOperACTIVTO             TimeInterval,        sdlcPortOperPAUSE               TimeInterval,        sdlcPortOperSlowPollMethod      INTEGER,        sdlcPortOperSERVLIM             Integer32,        sdlcPortOperSlowPollTimer       TimeInterval,        sdlcPortOperLastModifyTime      TimeTicks,        sdlcPortOperLastFailTime        TimeTicks,        sdlcPortOperLastFailCause       INTEGER}sdlcPortOperName    OBJECT-TYPE                    SYNTAX      DisplayString (SIZE (1..8))                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "An octet string that describes the physical                        port to which this interface is currently                        attached.  It has  implementation-specific                        significance."                    ::= { sdlcPortOperEntry 1 }sdlcPortOperRole    OBJECT-TYPE                    SYNTAX      INTEGER                    {                        primary(1),                        secondary(2),                        undefined(3)                    }                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This object describes the role that the link                        station has assumed on this connection.                        Even though this is defined as a port object,                        it is a link station attribute in the sense                        that a role is per link station.  However, it                        is not possible to vary link station roles on a                        particular port.  For example, if an SDLC port                        is configured to primary, all link stations on                        that port must be primary.                        The value of sdlcPortOperRole is undefined(3)                        whenever the link station role has not yet been                        established by the mode setting command."                    ::= { sdlcPortOperEntry 2 }sdlcPortOperType    OBJECT-TYPE                    SYNTAX      INTEGER                    {                         leased(1),                         switched(2)                    }                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This parameter defines whether the SDLC port                        is currently operating as though connected to a                        leased or switched line."                    ::= { sdlcPortOperEntry 3 }sdlcPortOperTopology  OBJECT-TYPE                    SYNTAX      INTEGER                    {                         pointToPoint(1),                         multipoint(2)                    }                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This parameter defines whether the SDLC port is                        currently operating in a point-to-point or                        multipoint topology."                    ::= { sdlcPortOperEntry 4 }sdlcPortOperISTATUS OBJECT-TYPE                    SYNTAX      INTEGER                    {                         inactive(1),                         active(2)                    }                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This parameter describes the initial value of                        the administrative status, ifAdminStatus, of                        this SDLC port at last port start-up."                    ::= { sdlcPortOperEntry 5 }sdlcPortOperACTIVTO OBJECT-TYPE                    SYNTAX      TimeInterval                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This parameter defines the period of time (in                        100ths of a second) that the port will allow a                        switched line to remain inactive before                        disconnecting.  A switched line is considered                        to be inactive if there are no I-Frames being                        transferred.                        The object descriptor contains the name of an                        NCP configuration parameter, ACTIVTO.  Please                        note that the value of this object represents                        1/100ths of a second while the NCP ACTIVTO is                        represented in seconds.                        A value of zero indicates no timeout."                    ::= { sdlcPortOperEntry 6 }sdlcPortOperPAUSE   OBJECT-TYPE                    SYNTAX      TimeInterval                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This object describes the current minimum                        elapsed time (in 1/100ths of a second) between                        any two traversals of the poll list for a                        primary SDLC port.                        The object descriptor contains the name of an                        NCP configuration parameter, PAUSE.  Please                        note that the value of this object represents                        1/100ths of a second while the NCP PAUSE is                        represented in 1/10ths of a second.                        This object only has meaning for SDLC ports                        where                            sdlcPortAdminRole == primary "                    ::= { sdlcPortOperEntry 7 }sdlcPortOperSlowPollMethod OBJECT-TYPE                    SYNTAX      INTEGER                    {                         servlim(1),                         pollpause(2),                         other(3)                    }                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This object defines the exact method that is in                        effect for periodically polling failed secondary                        link station addresses.                        If sdlcPortOperSlowPollMethod == servlim, then                        sdlcPortOperSERVLIM defines the actual polling                        characteristics.                        If sdlcPortOperSlowPollMethod == pollpause,                        then sdlcPortOperSlowPollTimer defines the                        actual polling characteristics.                        If sdlcPortOperSlowPollMethod == other, then                        the polling characteristics are modeled in                        vendor-specific objects.                        This object only has meaning for SDLC ports                        where                            sdlcPortOperRole == primary                        and                            sdlcPortOperTopology == multipoint "                    ::= { sdlcPortOperEntry 8 }sdlcPortOperSERVLIM OBJECT-TYPE                    SYNTAX      Integer32                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This object describes the number of times the                        active poll list is currently being traversed                        before polling a station on the slow poll list                        for a primary, multipoint SDLC port.                        This object only has meaning for SDLC ports                        where                            sdlcPortOperRole == primary                        and                            sdlcPortOperTopology == multipoint "                    ::= { sdlcPortOperEntry 9 }sdlcPortOperSlowPollTimer OBJECT-TYPE                    SYNTAX      TimeInterval                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This object describes the elapsed time (in                        1/100ths of a second) between polls for failed                        secondary link station addresses.                        This object only has meaning for SDLC ports                        where                            sdlcPortOperRole == primary                        and                            sdlcPortOperTopology == multipoint "                    ::= { sdlcPortOperEntry 10 }sdlcPortOperLastModifyTime    OBJECT-TYPE                    SYNTAX      TimeTicks                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This object describes the value of sysUpTime                         when this port definition was last modified.                         If the port has not been modified, then this                         value shall be zero."                    ::= { sdlcPortOperEntry 11 }sdlcPortOperLastFailTime    OBJECT-TYPE                    SYNTAX      TimeTicks                    MAX-ACCESS  read-only                    STATUS      current                    DESCRIPTION                        "This object describes the value of sysUpTime                        when this SDLC port last failed.  If the port                        has not failed, then this value shall be zero."                    ::= { sdlcPortOperEntry 12 }sdlcPortOperLastFailCause    OBJECT-TYPE                    SYNTAX      INTEGER                    {                        undefined(1),                        physical(2)                    }

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -