⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1286.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 4 页
字号:
   RFC1286-MIB DEFINITIONS ::= BEGIN   IMPORTS           Counter, Gauge, TimeTicks                   FROM RFC1155-SMI           mib-2                   FROM RFC1213-MIB           OBJECT-TYPE                   FROM RFC-1212           TRAP-TYPE                   FROM RFC-1215;   -- All representations of MAC addresses in this MIB Module use,   -- as a textual convention (i.e. this convention does not affect   -- their encoding), the data type:   MacAddress ::= OCTET STRING (SIZE (6))    -- a 6 octet address in                                             -- the "canonical" order   -- defined by IEEE 802.1a, i.e., as if it were transmitted least   -- significant bit first, even though 802.5 (in contrast to other   -- 802.x protocols) requires MAC addresses to be transmitted most   -- significant bit first.   --   -- 16-bit addresses, if needed, are represented by setting their   -- upper 4 octets to all 0's, i.e., AAFF would be represented   -- as 00000000AAFF.   -- Similarly, all representations of Bridge-Id in this MIB Module   -- use, as a textual convention (i.e. this convention does not affect   -- their encoding), the data type:   BridgeId ::= OCTET STRING (SIZE (8))   -- the Bridge-Identifier as                                          -- used in the Spanning Tree   -- Protocol to uniquely identify a bridge.  Its first two octets   -- (in network byte order) contain a priority value and its last   -- 6 octets contain the MAC address used to refer to a bridge in a   -- unique fashion (typically, the numerically smallest MAC address   -- of all ports on the bridge).   -- Several objects in this MIB module represent values of timers   -- used by the Spanning Tree Protocol.  In this MIB, these timers   -- have values in units of hundreths of a second (i.e. 1/100 secs).   -- These timers, when stored in a Spanning Tree Protocol's BPDU,   -- are in units of 1/256 seconds.  Note, however, that 802.1d/D9   -- specifies a settable granularity of no more than 1 second for   -- these timers.  To avoid ambiguity, a data type is defined here   -- as a textual convention and all representation of these timers   -- in this MIB module are defined using this data type.  An algorithm   -- is also defined for converting between the different units, to   -- ensure a timer's value is not distorted by multiple conversions.   -- The data type is:   Timeout ::= INTEGER      -- a STP timer in units of 1/100 seconds   -- To convert a Timeout value into a value in units of   -- 1/256 seconds, the following algorithm should be used:   --   --      b  = floor( (n * 256) / 100)   --   -- where:   --      floor   =  quotient [ignore remainder]   --      n is the value in 1/100 second units   --      b is the value in 1/256 second units   --   -- To convert the value from 1/256 second units back to   -- 1/100 seconds, the following algorithm should be used:   --   --      n = ceiling( (b * 100) / 256)   --   -- where:   --      ceiling =  quotient [if remainder is 0], or   --                 quotient + 1 [if remainder is non-zero]   --      n is the value in 1/100 second units   --      b is the value in 1/256 second units   --   -- Note: it is important that the arithmetic operations are done   -- in the order specified (i.e., multiply first, divide second).   dot1dBridge   OBJECT IDENTIFIER ::= { mib-2 17 }   -- groups in the Bridge MIB   dot1dBase     OBJECT IDENTIFIER ::= { dot1dBridge 1 }   dot1dStp      OBJECT IDENTIFIER ::= { dot1dBridge 2 }   dot1dSr       OBJECT IDENTIFIER ::= { dot1dBridge 3 }   dot1dTp       OBJECT IDENTIFIER ::= { dot1dBridge 4 }   dot1dStatic   OBJECT IDENTIFIER ::= { dot1dBridge 5 }   -- the dot1dBase group   -- Implementation of the dot1dBase group is mandatory for all   -- bridges.   dot1dBaseBridgeAddress OBJECT-TYPE       SYNTAX  MacAddress       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "The MAC address used by this bridge when it must               be referred to in a unique fashion.   It is               recommended that this be the numerically smallest               MAC address of all ports that belong to this               bridge.  However it is only required to be unique.               When concatenated with dot1dStpPriority a unique               BridgeIdentifier is formed which is used in the               Spanning Tree Protocol."       REFERENCE               "P802.1d/D9, July 14, 1989: Sections 6.4.1.1.3 and 3.12.5"       ::= { dot1dBase 1 }   dot1dBaseNumPorts OBJECT-TYPE       SYNTAX  INTEGER       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "The number of ports controlled by this bridging               entity."       REFERENCE               "P802.1d/D9, July 14, 1989: Section 6.4.1.1.3"       ::= { dot1dBase 2 }   dot1dBaseType OBJECT-TYPE       SYNTAX  INTEGER {                   unknown(1),                   transparent-only(2),                   sourceroute-only(3),                   srt(4)               }       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "Indicates what type of bridging this bridge can               perform.  If a bridge is actually performing a               certain type of bridging this will be indicated by               entries in the port table for the given type."       ::= { dot1dBase 3 }   -- The Generic Bridge Port Table   dot1dBasePortTable OBJECT-TYPE       SYNTAX  SEQUENCE OF Dot1dBasePortEntry       ACCESS  not-accessible       STATUS  mandatory       DESCRIPTION               "A table that contains generic information about               every port that is associated with this bridge.               Transparent, source-route, and srt ports are               included."       ::= { dot1dBase 4 }   dot1dBasePortEntry OBJECT-TYPE       SYNTAX  Dot1dBasePortEntry       ACCESS  not-accessible       STATUS  mandatory       DESCRIPTION               "A list of information for each port of the               bridge."       REFERENCE               "P802.1d/D9, July 14, 1989: Section 6.4.2, 6.6.1"       INDEX  { dot1dBasePort }       ::= { dot1dBasePortTable 1 }   Dot1dBasePortEntry ::=       SEQUENCE {           dot1dBasePort               INTEGER,           dot1dBasePortIfIndex               INTEGER,           dot1dBasePortCircuit               OBJECT IDENTIFIER,           dot1dBasePortDelayExceededDiscards               Counter,           dot1dBasePortMtuExceededDiscards               Counter       }   dot1dBasePort OBJECT-TYPE       SYNTAX  INTEGER       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "The port number of the port for which this entry               contains bridge management information."       ::= { dot1dBasePortEntry 1 }   dot1dBasePortIfIndex OBJECT-TYPE       SYNTAX  INTEGER       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "The value of the instance of the ifIndex object,               defined in [4,6], for the interface corresponding               to this port."       ::= { dot1dBasePortEntry 2 }   dot1dBasePortCircuit OBJECT-TYPE       SYNTAX  OBJECT IDENTIFIER       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "For a port which (potentially) has the same value               of dot1dBasePortIfIndex as another port on the               same bridge, this object contains the name of an               object instance unique to this port.  For example,               in the case where multiple ports correspond one-               to-one with multiple X.25 virtual circuits, this               value might identify an (e.g., the first) object               instance associated with the X.25 virtual circuit               corresponding to this port.               For a port which has a unique value of               dot1dBasePortIfIndex, this object can have the               value { 0 0 }."       ::= { dot1dBasePortEntry 3 }   dot1dBasePortDelayExceededDiscards OBJECT-TYPE       SYNTAX  Counter       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "The number of frames discarded by this port due               to excessive transit delay through the bridge.  It               is incremented by both transparent and source               route bridges."       REFERENCE                "P802.1d/D9, July 14, 1989: Section 6.6.1.1.3"       ::= { dot1dBasePortEntry 4 }   dot1dBasePortMtuExceededDiscards OBJECT-TYPE       SYNTAX  Counter       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "The number of frames discarded by this port due               to an excessive size.  It is incremented by both               transparent and source route bridges."       REFERENCE               "P802.1d/D9, July 14, 1989: Section 6.6.1.1.3"       ::= { dot1dBasePortEntry 5 }   -- the dot1dStp group   -- Implementation of the dot1dStp group is optional.  It is   -- implemented by those bridges that support the Spanning Tree   -- Protocol.  Transparent, Source Route, and SRT bridges will   -- implement this group only if they support the Spanning Tree   -- Protocol.   dot1dStpProtocolSpecification OBJECT-TYPE       SYNTAX  INTEGER {                   unknown(1),                   decLb100(2),                   ieee8021d(3)               }       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "An indication of what version of the Spanning               Tree Protocol is being run.  The value               'decLb100(2)' indicates the DEC LANbridge 100               Spanning Tree protocol.  IEEE 802.1d               implementations will return 'ieee8021d(3)'.  If               future versions of the IEEE Spanning Tree Protocol               are released that are incompatible with the               current version a new value will be defined."       ::= { dot1dStp 1 }   dot1dStpPriority OBJECT-TYPE       SYNTAX  INTEGER (0..65535)       ACCESS  read-write       STATUS  mandatory       DESCRIPTION               "The value of the write-able portion of the Bridge               ID, i.e., the first two octets of the (8 octet               long) Bridge ID.  The other (last) 6 octets of the               Bridge ID are given by the value of               dot1dBaseBridgeAddress."       REFERENCE               "P802.1d/D9, July 14, 1989: Section 4.5.3.7"       ::= { dot1dStp 2 }   dot1dStpTimeSinceTopologyChange OBJECT-TYPE       SYNTAX  TimeTicks       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "The time (in hundredths of a second) since the               last time a topology change was detected by the               bridge entity."       REFERENCE               "P802.1d/D9, July 14, 1989: Section 6.8.1.1.3"       ::= { dot1dStp 3 }   dot1dStpTopChanges OBJECT-TYPE       SYNTAX  Counter       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "The total number of topology changes detected by               this bridge since the management entity was last               reset or initialized."       REFERENCE               "P802.1d/D9, July 14, 1989: Section 6.8.1.1.3"       ::= { dot1dStp 4 }   dot1dStpDesignatedRoot OBJECT-TYPE       SYNTAX  BridgeId       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "The bridge identifier of the root of the spanning               tree as determined by the Spanning Tree Protocol               as executed by this node.  This value is used as               the Root Identifier parameter in all Configuration               Bridge PDUs originated by this node."       REFERENCE               "P802.1d/D9, July 14, 1989: Section 4.5.3.1"       ::= { dot1dStp 5 }   dot1dStpRootCost OBJECT-TYPE       SYNTAX  INTEGER       ACCESS  read-only       STATUS  mandatory       DESCRIPTION               "The cost of the path to the root as seen from               this bridge."       REFERENCE               "P802.1d/D9, July 14, 1989: Section 4.5.3.2"

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -