⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc3412.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
字号:
   SNMP-MPD-MIB DEFINITIONS ::= BEGIN   IMPORTS       MODULE-COMPLIANCE, OBJECT-GROUP         FROM SNMPv2-CONF       MODULE-IDENTITY, OBJECT-TYPE,       snmpModules, Counter32                  FROM SNMPv2-SMI;   snmpMPDMIB MODULE-IDENTITY       LAST-UPDATED "200210140000Z"       ORGANIZATION "SNMPv3 Working Group"       CONTACT-INFO "WG-EMail:   snmpv3@lists.tislabs.com                     Subscribe:  snmpv3-request@lists.tislabs.com                     Co-Chair:   Russ Mundy                                 Network Associates Laboratories                     postal:     15204 Omega Drive, Suite 300                                 Rockville, MD 20850-4601                                 USA                     EMail:      mundy@tislabs.com                     phone:      +1 301-947-7107                     Co-Chair &                     Co-editor:  David Harrington                                 Enterasys Networks                     postal:     35 Industrial Way                                 P. O. Box 5005                                 Rochester NH 03866-5005                                 USA                     EMail:      dbh@enterasys.com                     phone:      +1 603-337-2614                     Co-editor:  Jeffrey Case                                 SNMP Research, Inc.                     postal:     3001 Kimberlin Heights Road                                 Knoxville, TN 37920-9716                                 USA                     EMail:      case@snmp.com                     phone:      +1 423-573-1434                     Co-editor:  Randy Presuhn                                 BMC Software, Inc.                     postal:     2141 North First Street                                 San Jose, CA 95131                                 USA                     EMail:      randy_presuhn@bmc.com                     phone:      +1 408-546-1006                     Co-editor:  Bert Wijnen                                 Lucent Technologies                     postal:     Schagen 33                                 3461 GL Linschoten                                 Netherlands                     EMail:      bwijnen@lucent.com                     phone:      +31 348-680-485                    "       DESCRIPTION  "The MIB for Message Processing and Dispatching                     Copyright (C) The Internet Society (2002). This                     version of this MIB module is part of RFC 3412;                     see the RFC itself for full legal notices.                    "       REVISION     "200210140000Z"            -- 14 October 2002       DESCRIPTION  "Updated addresses, published as RFC 3412."       REVISION     "199905041636Z"            -- 4 May 1999       DESCRIPTION  "Updated addresses, published as RFC 2572."       REVISION     "199709300000Z"            -- 30 September 1997       DESCRIPTION  "Original version, published as RFC 2272."       ::= { snmpModules 11 }   -- Administrative assignments ***************************************   snmpMPDAdmin           OBJECT IDENTIFIER ::= { snmpMPDMIB 1 }   snmpMPDMIBObjects      OBJECT IDENTIFIER ::= { snmpMPDMIB 2 }   snmpMPDMIBConformance  OBJECT IDENTIFIER ::= { snmpMPDMIB 3 }   -- Statistics for SNMP Messages *************************************   snmpMPDStats           OBJECT IDENTIFIER ::= { snmpMPDMIBObjects 1 }   snmpUnknownSecurityModels OBJECT-TYPE       SYNTAX       Counter32       MAX-ACCESS   read-only       STATUS       current       DESCRIPTION "The total number of packets received by the SNMP                    engine which were dropped because they referenced a                    securityModel that was not known to or supported by                    the SNMP engine.                   "       ::= { snmpMPDStats 1 }   snmpInvalidMsgs OBJECT-TYPE       SYNTAX       Counter32       MAX-ACCESS   read-only       STATUS       current       DESCRIPTION "The total number of packets received by the SNMP                    engine which were dropped because there were invalid                    or inconsistent components in the SNMP message.                   "       ::= { snmpMPDStats 2 }   snmpUnknownPDUHandlers OBJECT-TYPE       SYNTAX       Counter32       MAX-ACCESS   read-only       STATUS       current       DESCRIPTION "The total number of packets received by the SNMP                    engine which were dropped because the PDU contained                    in the packet could not be passed to an application                    responsible for handling the pduType, e.g. no SNMP                    application had registered for the proper                    combination of the contextEngineID and the pduType.                   "       ::= { snmpMPDStats 3 }   -- Conformance information ******************************************   snmpMPDMIBCompliances OBJECT IDENTIFIER ::= {snmpMPDMIBConformance 1}   snmpMPDMIBGroups      OBJECT IDENTIFIER ::= {snmpMPDMIBConformance 2}   -- Compliance statements   snmpMPDCompliance MODULE-COMPLIANCE       STATUS       current       DESCRIPTION "The compliance statement for SNMP entities which                    implement the SNMP-MPD-MIB.                   "       MODULE    -- this module           MANDATORY-GROUPS { snmpMPDGroup }       ::= { snmpMPDMIBCompliances 1 }   snmpMPDGroup OBJECT-GROUP       OBJECTS {                 snmpUnknownSecurityModels,                 snmpInvalidMsgs,                 snmpUnknownPDUHandlers               }       STATUS       current       DESCRIPTION "A collection of objects providing for remote                    monitoring of the SNMP Message Processing and                    Dispatching process.                   "       ::= { snmpMPDMIBGroups 1 }   END

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -