📄 rfc1407.mib
字号:
SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3FarEndCurrentEntry 6 } dsx3FarEndCurrentUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End unavailable seconds encountered by a DS3 interface in the current 15 minute interval." ::= { dsx3FarEndCurrentEntry 7 } -- The DS3 Far End Interval -- The DS3 Far End Interval Table contains various statistics -- collected by each DS3 interface over the previous 24 -- hours of operation. The past 24 hours are broken into 96 -- completed 15 minute intervals. dsx3FarEndIntervalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Interval table." ::= { ds3 11 } dsx3FarEndIntervalEntry OBJECT-TYPE SYNTAX Dsx3FarEndIntervalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3 Far End Interval table." INDEX { dsx3FarEndIntervalIndex, dsx3FarEndIntervalNumber } ::= { dsx3FarEndIntervalTable 1 } Dsx3FarEndIntervalEntry ::= SEQUENCE { dsx3FarEndIntervalIndex INTEGER, dsx3FarEndIntervalNumber INTEGER, dsx3FarEndIntervalCESs Gauge, dsx3FarEndIntervalCSESs Gauge, dsx3FarEndIntervalCCVs Gauge, dsx3FarEndIntervalUASs Gauge } dsx3FarEndIntervalIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FarEndIntervalEntry 1 } dsx3FarEndIntervalNumber OBJECT-TYPE SYNTAX INTEGER (1..96) ACCESS read-only STATUS mandatory DESCRIPTION "A number between 1 and 96, where 1 is the most recently completed 15 minute interval and 96 is the least recently completed 15 minutes interval (assuming that all 96 intervals are valid)." ::= { dsx3FarEndIntervalEntry 2 } dsx3FarEndIntervalCESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Errored Seconds encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3FarEndIntervalEntry 3 } dsx3FarEndIntervalCSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Severely Errored Seconds encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3FarEndIntervalEntry 4 } dsx3FarEndIntervalCCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3FarEndIntervalEntry 5 } dsx3FarEndIntervalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End unavailable seconds encountered by a DS3 interface in one of the previous 96, individual 15 minute, intervals." ::= { dsx3FarEndIntervalEntry 6 } -- The DS3 Far End Total -- The DS3 Far End Total Table contains the cumulative sum -- of the various statistics for the 24 hour period preceding -- the current interval. dsx3FarEndTotalTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FarEndTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Far End Total table. 24 hour interval." ::= { ds3 12 } dsx3FarEndTotalEntry OBJECT-TYPE SYNTAX Dsx3FarEndTotalEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3 Far End Total table." INDEX { dsx3FarEndTotalIndex } ::= { dsx3FarEndTotalTable 1 } Dsx3FarEndTotalEntry ::= SEQUENCE { dsx3FarEndTotalIndex INTEGER, dsx3FarEndTotalCESs Gauge, dsx3FarEndTotalCSESs Gauge, dsx3FarEndTotalCCVs Gauge, dsx3FarEndTotalUASs Gauge } dsx3FarEndTotalIndex OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable. The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FarEndTotalEntry 1 } dsx3FarEndTotalCESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Errored Seconds encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3FarEndTotalEntry 2 } dsx3FarEndTotalCSESs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Severely Errored Seconds encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3FarEndTotalEntry 3 } dsx3FarEndTotalCCVs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End C-bit Coding Violations reported via the far end block error count encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3FarEndTotalEntry 4 } dsx3FarEndTotalUASs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The counter associated with the number of Far End unavailable seconds encountered by a DS3 interface in the previous 24 hour interval." ::= { dsx3FarEndTotalEntry 5 } -- the DS3/E3 Fractional Group -- Implementation of this group is optional. It is designed -- for those systems dividing a DS3/E3 into channels -- containing different data streams that are of local -- interest. -- The DS3/E3 fractional table identifies which DS3/E3 -- channels associated with a CSU are being used to -- support a logical interface, i.e., an entry in the -- interfaces table from the Internet-standard MIB. -- For example, consider a DS3 device with 4 high speed links -- carrying router traffic, a feed for voice, a feed for -- video, and a synchronous channel for a non-routed -- protocol. -- We might describe the allocation of channels, in the -- dsx3FracTable, as follows: -- dsx3FracIfIndex.2. 1 = 3 dsx3FracIfIndex.2.15 = 4 -- dsx3FracIfIndex.2. 2 = 3 dsx3FracIfIndex.2.16 = 6 -- dsx3FracIfIndex.2. 3 = 3 dsx3FracIfIndex.2.17 = 6 -- dsx3FracIfIndex.2. 4 = 3 dsx3FracIfIndex.2.18 = 6 -- dsx3FracIfIndex.2. 5 = 3 dsx3FracIfIndex.2.19 = 6 -- dsx3FracIfIndex.2. 6 = 3 dsx3FracIfIndex.2.20 = 6 -- dsx3FracIfIndex.2. 7 = 4 dsx3FracIfIndex.2.21 = 6 -- dsx3FracIfIndex.2. 8 = 4 dsx3FracIfIndex.2.22 = 6 -- dsx3FracIfIndex.2. 9 = 4 dsx3FracIfIndex.2.23 = 6 -- dsx3FracIfIndex.2.10 = 4 dsx3FracIfIndex.2.24 = 6 -- dsx3FracIfIndex.2.11 = 4 dsx3FracIfIndex.2.25 = 6 -- dsx3FracIfIndex.2.12 = 5 dsx3FracIfIndex.2.26 = 6 -- dsx3FracIfIndex.2.13 = 5 dsx3FracIfIndex.2.27 = 6 -- dsx3FracIfIndex.2.14 = 5 dsx3FracIfIndex.2.28 = 6 -- For dsx3M23, dsx3SYNTRAN, dsx3CbitParity, and -- dsx3ClearChannel there are 28 legal channels, numbered 1 -- through 28. -- For e3Framed there are 16 legal channels, -- numbered 1 through 16. The channels (1..16) correspond -- directly to the equivalently numbered time-slots. dsx3FracTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx3FracEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The DS3 Fractional table." ::= { ds3 13 } dsx3FracEntry OBJECT-TYPE SYNTAX Dsx3FracEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the DS3 Fractional table." INDEX { dsx3FracIndex, dsx3FracNumber } ::= { dsx3FracTable 1 } Dsx3FracEntry ::= SEQUENCE { dsx3FracIndex INTEGER, dsx3FracNumber INTEGER, dsx3FracIfIndex INTEGER } dsx3FracIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) ACCESS read-only STATUS mandatory DESCRIPTION "The index value which uniquely identifies the DS3 interface to which this entry is applicable The interface identified by a particular value of this index is the same interface as identified by the same value an dsx3LineIndex object instance." ::= { dsx3FracEntry 1 } dsx3FracNumber OBJECT-TYPE SYNTAX INTEGER (1..31) ACCESS read-only STATUS mandatory DESCRIPTION "The channel number for this entry." ::= { dsx3FracEntry 2 } dsx3FracIfIndex OBJECT-TYPE SYNTAX INTEGER (1..'7fffffff'h) ACCESS read-write STATUS mandatory DESCRIPTION "An index value that uniquely identifies an interface. The interface identified by a particular value of this index is the same interface as identified by the same value an ifIndex object instance. If no interface is currently using a channel, the value should be zero. If a single interface occupies more than one time slot, that ifIndex value will be found in multiple time slots." ::= { dsx3FracEntry 3 } END
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -