⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2954.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
        frPVCEndptOutFrames OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames sent by the network (egress)                    regardless of whether they are Bc or Be frames for                    this PVC end-point."            ::= { frPVCEndptEntry 14 }        frPVCEndptInDEFrames OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames received by the network                    (ingress) with the DE bit set to (1) for this PVC                    end-point."            ::= { frPVCEndptEntry 15 }        frPVCEndptInExcessFrames OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames received by the network                    (ingress) for this PVC end-point which were                    treated as excess traffic.  Frames which are sent                    to the network with DE set to zero are treated as                    excess when more than Bc bits are submitted to the                    network during the Committed Information Rate                    Measurement Interval (Tc).  Excess traffic may or                    may not be discarded at the ingress if more than                    Bc + Be bits are submitted to the network during                    Tc.  Traffic discarded at the ingress is not                    recorded in frPVCEndptInExcessFrames.  Frames                    which are sent to the network with DE set to one                    are also treated as excess traffic."            ::= { frPVCEndptEntry 16 }        frPVCEndptOutExcessFrames OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames sent by the network (egress)                    for this PVC end-point which were treated as                    excess traffic.  (The DE bit may be set to one.)"            ::= { frPVCEndptEntry 17 }        frPVCEndptInDiscards OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames received by the network                    (ingress) that were discarded due to traffic                    enforcement for this PVC end-point.  Congestion                    discards are not counted in this object."            ::= { frPVCEndptEntry 18 }        frPVCEndptInOctets OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Octets"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of octets received by the network                    (ingress) for this PVC end-point.  This counter                    should only count octets from the beginning of the                    frame relay header field to the end of user data.                    If the network supporting frame relay can not                    count octets, then this count should be an                    approximation."            ::= { frPVCEndptEntry 19 }        frPVCEndptOutOctets OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Octets"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of octets sent by the network (egress)                    for this PVC end-point.  This counter should only                    count octets from the beginning of the frame relay                    header field to the end of user data.  If the                    network supporting frame relay can not count                    octets, then this count should be an                    approximation."            ::= { frPVCEndptEntry 20 }        frPVCEndptInDiscardsDESet OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames received by the network                    (ingress) that were discarded with the DE bit set                    due to traffic enforcement for this PVC end-point.                    Congestion discards are not counted in this                    object."            ::= { frPVCEndptEntry 21 }        frPVCEndptInFramesFECNSet OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames received by the network                    (ingress) that have the FECN bit set for this PVC                    end-point."            ::= { frPVCEndptEntry 22 }        frPVCEndptOutFramesFECNSet OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames sent by the network (egress)                    that have the FECN bit set for this PVC end-                    point."            ::= { frPVCEndptEntry 23 }        frPVCEndptInFramesBECNSet OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames received by the network                    (ingress) that have the BECN bit set for this PVC                    end-point."            ::= { frPVCEndptEntry 24 }        frPVCEndptOutFramesBECNSet OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames sent by the network (egress)                    that have the BECN bit set for this PVC end-                    point."            ::= { frPVCEndptEntry 25 }        frPVCEndptInCongDiscards OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames received by the network                    (ingress) that were discarded due to input buffer                    congestion, rather than traffic enforcement, for                    this PVC end-point."            ::= { frPVCEndptEntry 26 }        frPVCEndptInDECongDiscards OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames counted by                    frPVCEndptInCongDiscards with the DE bit set to                    (1)."            ::= { frPVCEndptEntry 27 }        frPVCEndptOutCongDiscards OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames sent by the network (egress)                    that were discarded due to output buffer                    congestion for this PVC end-point."            ::= { frPVCEndptEntry 28 }        frPVCEndptOutDECongDiscards OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames counted by                    frPVCEndptOutCongDiscards with the DE bit set to                    (1)."            ::= { frPVCEndptEntry 29 }        frPVCEndptOutDEFrames OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames sent by the network (egress)                    with the DE bit set to (1) for this PVC end-                    point."            ::= { frPVCEndptEntry 30 }        frPVCEndptAtmIwfConnIndex OBJECT-TYPE            SYNTAX      Integer32  (0..2147483647)            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "This object contains the index value of the                    FR/ATM cross-connect table entry used to link the                    frame relay PVC with an ATM PVC.                    Each row of the frPVCEndptTable that is not                    cross-connected with an ATM PVC must return the                    value zero when this object is read.                    The value of this object is initialized by the                    agent after the associated entries in the                    frAtmIwfConnectionTable have been created.                    The value of this object is reset to zero                    following destruction of the associated entry in                    the frAtmIwfConnectionTable"            ::= { frPVCEndptEntry 31 }        --        -- Frame Relay PVC Connections        --        frPVCConnectIndexValue OBJECT-TYPE            SYNTAX      INTEGER (0..2147483647)            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "This object returns a hint to be used for                    frPVCConnectIndex when creating entries in the                    frPVCConnectTable.                    The value 0 indicates that no unassigned entries                    are available.                    To obtain the frPVCConnectIndex value for a new                    entry, the manager issues a management protocol                    retrieval operation to obtain the current value of                    this object.  After each retrieval, the agent must                    modify the value to the next unassigned index to                    prevent assignment of the same value to multiple                    management systems.                    A management system should repeat the read to                    obtain a new value should an attempt to create the                    new row using the previously returned hint fail."            ::= { frnetservObjects 4 }        frPVCConnectTable OBJECT-TYPE            SYNTAX      SEQUENCE OF FrPVCConnectEntry            MAX-ACCESS  not-accessible            STATUS      current            DESCRIPTION                    "The Frame Relay PVC Connect Table is used to                    model the bi-directional PVC segment flows                    including:  point-to-point PVCs, point-to-                    multipoint PVCs, and multipoint-to-multipoint                    PVCs.                    This table has read-create access and is used to                    associate PVC end-points together as belonging to                    one connection.  The frPVCConnectIndex is used to                    associate all the bi-directional flows.  Not all                    implementations will support the capability of                    creating/modifying/deleting PVCs using SNMP as a                    feature of frame relay CNM service.                    Once the entries in the frPVCEndptTable are                    created, the following step are used to associate                    the PVC end-points as belonging to one PVC                    connection:                    1)  Obtain a unique frPVCConnectIndex                        using the frPVCConnectIndexValue object.                    2)  Connect the PVC segment endpoints together                        with the applicable frPVCConnectIndex value                        obtained via  frPVCConnectIndexValue.  The                        entries in this table are created by using                        the frPVCConnectRowStatus object.                    3)  The agent will provide the value of the                        corresponding instances of                        frPVCEndptConnectIdentifier with the                        frPVCConnectIndex value.                    4)  Set frPVCConnectAdminStatus to `active(1)' in                        all rows for this PVC segment to turn the                        PVC on.        

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -