📄 rfc2954.mib
字号:
frPVCEndptOutFrames OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames sent by the network (egress) regardless of whether they are Bc or Be frames for this PVC end-point." ::= { frPVCEndptEntry 14 } frPVCEndptInDEFrames OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received by the network (ingress) with the DE bit set to (1) for this PVC end-point." ::= { frPVCEndptEntry 15 } frPVCEndptInExcessFrames OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received by the network (ingress) for this PVC end-point which were treated as excess traffic. Frames which are sent to the network with DE set to zero are treated as excess when more than Bc bits are submitted to the network during the Committed Information Rate Measurement Interval (Tc). Excess traffic may or may not be discarded at the ingress if more than Bc + Be bits are submitted to the network during Tc. Traffic discarded at the ingress is not recorded in frPVCEndptInExcessFrames. Frames which are sent to the network with DE set to one are also treated as excess traffic." ::= { frPVCEndptEntry 16 } frPVCEndptOutExcessFrames OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames sent by the network (egress) for this PVC end-point which were treated as excess traffic. (The DE bit may be set to one.)" ::= { frPVCEndptEntry 17 } frPVCEndptInDiscards OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received by the network (ingress) that were discarded due to traffic enforcement for this PVC end-point. Congestion discards are not counted in this object." ::= { frPVCEndptEntry 18 } frPVCEndptInOctets OBJECT-TYPE SYNTAX Counter32 UNITS "Octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets received by the network (ingress) for this PVC end-point. This counter should only count octets from the beginning of the frame relay header field to the end of user data. If the network supporting frame relay can not count octets, then this count should be an approximation." ::= { frPVCEndptEntry 19 } frPVCEndptOutOctets OBJECT-TYPE SYNTAX Counter32 UNITS "Octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of octets sent by the network (egress) for this PVC end-point. This counter should only count octets from the beginning of the frame relay header field to the end of user data. If the network supporting frame relay can not count octets, then this count should be an approximation." ::= { frPVCEndptEntry 20 } frPVCEndptInDiscardsDESet OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received by the network (ingress) that were discarded with the DE bit set due to traffic enforcement for this PVC end-point. Congestion discards are not counted in this object." ::= { frPVCEndptEntry 21 } frPVCEndptInFramesFECNSet OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received by the network (ingress) that have the FECN bit set for this PVC end-point." ::= { frPVCEndptEntry 22 } frPVCEndptOutFramesFECNSet OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames sent by the network (egress) that have the FECN bit set for this PVC end- point." ::= { frPVCEndptEntry 23 } frPVCEndptInFramesBECNSet OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received by the network (ingress) that have the BECN bit set for this PVC end-point." ::= { frPVCEndptEntry 24 } frPVCEndptOutFramesBECNSet OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames sent by the network (egress) that have the BECN bit set for this PVC end- point." ::= { frPVCEndptEntry 25 } frPVCEndptInCongDiscards OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames received by the network (ingress) that were discarded due to input buffer congestion, rather than traffic enforcement, for this PVC end-point." ::= { frPVCEndptEntry 26 } frPVCEndptInDECongDiscards OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames counted by frPVCEndptInCongDiscards with the DE bit set to (1)." ::= { frPVCEndptEntry 27 } frPVCEndptOutCongDiscards OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames sent by the network (egress) that were discarded due to output buffer congestion for this PVC end-point." ::= { frPVCEndptEntry 28 } frPVCEndptOutDECongDiscards OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames counted by frPVCEndptOutCongDiscards with the DE bit set to (1)." ::= { frPVCEndptEntry 29 } frPVCEndptOutDEFrames OBJECT-TYPE SYNTAX Counter32 UNITS "Frames" MAX-ACCESS read-only STATUS current DESCRIPTION "The number of frames sent by the network (egress) with the DE bit set to (1) for this PVC end- point." ::= { frPVCEndptEntry 30 } frPVCEndptAtmIwfConnIndex OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains the index value of the FR/ATM cross-connect table entry used to link the frame relay PVC with an ATM PVC. Each row of the frPVCEndptTable that is not cross-connected with an ATM PVC must return the value zero when this object is read. The value of this object is initialized by the agent after the associated entries in the frAtmIwfConnectionTable have been created. The value of this object is reset to zero following destruction of the associated entry in the frAtmIwfConnectionTable" ::= { frPVCEndptEntry 31 } -- -- Frame Relay PVC Connections -- frPVCConnectIndexValue OBJECT-TYPE SYNTAX INTEGER (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "This object returns a hint to be used for frPVCConnectIndex when creating entries in the frPVCConnectTable. The value 0 indicates that no unassigned entries are available. To obtain the frPVCConnectIndex value for a new entry, the manager issues a management protocol retrieval operation to obtain the current value of this object. After each retrieval, the agent must modify the value to the next unassigned index to prevent assignment of the same value to multiple management systems. A management system should repeat the read to obtain a new value should an attempt to create the new row using the previously returned hint fail." ::= { frnetservObjects 4 } frPVCConnectTable OBJECT-TYPE SYNTAX SEQUENCE OF FrPVCConnectEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The Frame Relay PVC Connect Table is used to model the bi-directional PVC segment flows including: point-to-point PVCs, point-to- multipoint PVCs, and multipoint-to-multipoint PVCs. This table has read-create access and is used to associate PVC end-points together as belonging to one connection. The frPVCConnectIndex is used to associate all the bi-directional flows. Not all implementations will support the capability of creating/modifying/deleting PVCs using SNMP as a feature of frame relay CNM service. Once the entries in the frPVCEndptTable are created, the following step are used to associate the PVC end-points as belonging to one PVC connection: 1) Obtain a unique frPVCConnectIndex using the frPVCConnectIndexValue object. 2) Connect the PVC segment endpoints together with the applicable frPVCConnectIndex value obtained via frPVCConnectIndexValue. The entries in this table are created by using the frPVCConnectRowStatus object. 3) The agent will provide the value of the corresponding instances of frPVCEndptConnectIdentifier with the frPVCConnectIndex value. 4) Set frPVCConnectAdminStatus to `active(1)' in all rows for this PVC segment to turn the PVC on.
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -