⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2954.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
                frPVCEndptConnectIdentifier    Integer32,                frPVCEndptRowStatus            RowStatus,                frPVCEndptRcvdSigStatus        INTEGER,                frPVCEndptInFrames             Counter32,                frPVCEndptOutFrames            Counter32,                frPVCEndptInDEFrames           Counter32,                frPVCEndptInExcessFrames       Counter32,                frPVCEndptOutExcessFrames      Counter32,                frPVCEndptInDiscards           Counter32,                frPVCEndptInOctets             Counter32,                frPVCEndptOutOctets            Counter32,                frPVCEndptInDiscardsDESet      Counter32,                frPVCEndptInFramesFECNSet      Counter32,                frPVCEndptOutFramesFECNSet     Counter32,                frPVCEndptInFramesBECNSet      Counter32,                frPVCEndptOutFramesBECNSet     Counter32,                frPVCEndptInCongDiscards       Counter32,                frPVCEndptInDECongDiscards     Counter32,                frPVCEndptOutCongDiscards      Counter32,                frPVCEndptOutDECongDiscards    Counter32,                frPVCEndptOutDEFrames          Counter32,                frPVCEndptAtmIwfConnIndex      Integer32            }        frPVCEndptDLCIIndex OBJECT-TYPE            SYNTAX      Integer32 (16..4194303)            MAX-ACCESS  not-accessible            STATUS      current            DESCRIPTION                    "The value of this object is equal to the DLCI                    value for this PVC end-point.                    The values are restricted to the legal range for                    the size of address field supported by the logical                    port (frLportAddrDLCILen)."            REFERENCE   "Q.922 [25]"            ::= { frPVCEndptEntry 1 }        frPVCEndptInMaxFrameSize OBJECT-TYPE            SYNTAX      Integer32 (1..4096)            UNITS       "Octets"            MAX-ACCESS  read-create            STATUS      current            DESCRIPTION                    "The value of this object is the size in octets of                    the largest frame relay information field for this                    PVC end-point in the ingress direction (into the                    frame relay network).  The value of                    frPVCEndptInMaxFrameSize must be less than or                    equal to the corresponding ifMtu for this frame                    relay UNI/NNI logical port."            REFERENCE   "FRF.1 [31]                         Q.922 [25]                         Q.933 [22]"            DEFVAL { 1600 }            ::= { frPVCEndptEntry 2 }        frPVCEndptInBc OBJECT-TYPE            SYNTAX      Integer32 (1..2147483647)            UNITS       "Bits"            MAX-ACCESS  read-create            STATUS      current            DESCRIPTION                    "The value of this object is equal to the                    committed burst size (Bc) parameter (measured in                    bits) for this PVC end-point in the ingress                    direction (into the frame relay network).                    Note that the max value of this range is lower                    than the max value allowed by Q.933 (16383 *                    10**6).                    Note that the value is encoded in bits whilst the                    Q.933 Link layer core parameters information                    element encodes this information using octet                    units."            REFERENCE   "Q.933 [22]"            ::= { frPVCEndptEntry 3 }        frPVCEndptInBe OBJECT-TYPE            SYNTAX      Integer32 (1..2147483647)            UNITS       "Bits"            MAX-ACCESS  read-create            STATUS      current            DESCRIPTION                    "The value of this object is equal to the excess                    burst size (Be) parameter (measured in bits) for                    this PVC end-point in the ingress direction (into                    the frame relay network).                    Note that the max value of this range is lower                    than the max value allowed by Q.933 (16383 *                    10**6).                    Note that the value is encoded in bits whilst the                    Q.933 Link layer core parameters information                    element encodes this information using octet                    units."            REFERENCE   "Q.933 [22]"            ::= { frPVCEndptEntry 4 }        frPVCEndptInCIR OBJECT-TYPE            SYNTAX      Integer32 (1..2147483647)            UNITS       "Bits per Second"            MAX-ACCESS  read-create            STATUS      current            DESCRIPTION                    "The value of this object is equal to the                    committed information rate (CIR) parameter                    (measured in bits per second) for this PVC end-                    point in the ingress direction (into the frame                    relay network).                    Note that the max value of this range is lower                    than the max value allowed by Q.933 (2047 *                    10**6)."            REFERENCE   "Q.933 [22]"            ::= { frPVCEndptEntry 5 }        frPVCEndptOutMaxFrameSize OBJECT-TYPE            SYNTAX      Integer32 (1..4096)            UNITS       "Octets"            MAX-ACCESS  read-create            STATUS      current            DESCRIPTION                    "The value of this object is the size in octets of                    the largest frame relay information field for this                    PVC end-point in the egress direction (out of the                    frame relay network).  The value of                    frPVCEndptOutMaxFrameSize must be less than or                    equal to the corresponding ifMtu for this frame                    relay UNI/NNI logical port."            REFERENCE   "FRF.1 [31]                         Q.922 [25]                         Q.933 [22]"            DEFVAL { 1600 }            ::= { frPVCEndptEntry 6 }        frPVCEndptOutBc OBJECT-TYPE            SYNTAX      Integer32 (1..2147483647)            UNITS       "Bits"            MAX-ACCESS  read-create            STATUS      current            DESCRIPTION                    "The value of this object is equal to the                    committed burst size (Bc) parameter (measured in                    bits) for this PVC end-point in the egress                    direction (out of the frame relay network).                    Note that the max value of this range is lower                    than the max value allowed by Q.933 (16383 *                    10**6).                    Note that the value is encoded in bits whilst the                    Q.933 Link layer core parameters information                    element encodes this information using octet                    units."            REFERENCE   "Q.933 [22]"            ::= { frPVCEndptEntry 7 }        frPVCEndptOutBe OBJECT-TYPE            SYNTAX      Integer32 (1..2147483647)            UNITS       "Bits"            MAX-ACCESS  read-create            STATUS      current            DESCRIPTION                    "The value of this object is equal to the excess                    burst size (Be) parameter (measured in bits) for                    this PVC end-point in the egress direction (out of                    the frame relay network).                    Note that the max value of this range is lower                    than the max value allowed by Q.933 (16383 *                    10**6).                    Note that the value is encoded in bits whilst the                    Q.933 Link layer core parameters information                    element encodes this information using octet                    units."            REFERENCE   "Q.933 [22]"            ::= { frPVCEndptEntry 8 }        frPVCEndptOutCIR OBJECT-TYPE            SYNTAX      Integer32 (1..2147483647)            UNITS       "Bits per Second"            MAX-ACCESS  read-create            STATUS      current            DESCRIPTION                    "The value of this object is equal to the                    committed information rate (CIR) parameter                    (measured in bits per second) for this PVC end-                    point in the egress direction (out of the frame                    relay network).                    Note that the max value of this range is lower                    than the max value allowed by Q.933 (2047 *                    10**6)."            REFERENCE   "Q.933 [22]"            ::= { frPVCEndptEntry 9 }        frPVCEndptConnectIdentifier OBJECT-TYPE            SYNTAX      Integer32 (0..2147483647)            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "This object is used to associate PVC end-points                    as being part of one PVC segment connection. This                    value of this object is equal to the value of                    frPVCConnectIndex, which is used as one of the                    indices into the frPVCConnectTable.                    A connection that has been cross-connected via the                    FR/ATM PVC Service IWF cross-connect table will                    return the value zero when this object is read. In                    case of these interworked connections, the                    frPVCEndptAtmIwfConnIndex object must be accessed                    to select the entry in the FR/ATM PVC Service IWF                    cross-connect table.                    The value of this object is provided by the agent,                    after the associated entries in the                    frPVCConnectTable or frAtmIwfConnectionTable have                    been created."            ::= { frPVCEndptEntry 10 }        frPVCEndptRowStatus OBJECT-TYPE            SYNTAX      RowStatus            MAX-ACCESS  read-create            STATUS      current            DESCRIPTION                    "This object is used to create new rows in this                    table, modify existing rows, and to delete                    existing rows.  To create a new PVC, the entries                    for the PVC segment end-points in the                    frPVCEndptTable must first be created.  Next, the                    frPVCConnectTable is used to associate the frame                    relay PVC segment end-points.  In order for the                    manager to have the necessary error diagnostics,                    the frPVCEndptRowStatus object must initially be                    set to `createAndWait(5)'.  While the                    frPVCEndptRowStatus object is in the                    `createAndWait(5)' state, the manager can set each                    columnar object and get the necessary error                    diagnostics.  The frPVCEndptRowStatus object may                    not be set to `active(1)' unless the following                    columnar objects exist in this row:                    frPVCEndptInMaxFrameSize, frPVCEndptInBc,                    frPVCEndptInBe, frPVCEndptInCIR,                    frPVCEndptOutMaxFrameSize, frPVCEndptOutBc,                    frPVCEndptOutBe, and frPVCEndptOutCIR."            ::= { frPVCEndptEntry 11 }        frPVCEndptRcvdSigStatus OBJECT-TYPE            SYNTAX      INTEGER {                        deleted(1),                        active(2),                        inactive(3),                        none(4)                        }            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The value of this object identifies the PVC                    status received via the local in-channel signaling                    procedures for this PVC end-point.  This object is                    only pertinent for interfaces that perform the                    bidirectional procedures.                    Each value has the following meaning:                      deleted(1):  This PVC is not listed in the full                                   status reports received from the                                   user device.  The object retains                                   this value for as long as the PVC                                   is not listed in the full status                                   reports                    active(2):   This PVC is reported as active, or                                   operational, by the user device.                      inactive(3): This PVC is reported as inactive,                                   or non-operational, by the user                                   device.                      none(4):     This interface is only using the                                   network-side in-channel signaling                                   procedures, so this object does                                   not apply."            ::= { frPVCEndptEntry 12 }        frPVCEndptInFrames OBJECT-TYPE            SYNTAX      Counter32            UNITS       "Frames"            MAX-ACCESS  read-only            STATUS      current            DESCRIPTION                    "The number of frames received by the network                    (ingress) for this PVC end-point. This includes                    any frames discarded by the network due to                    submitting more than Bc + Be data or due to any                    network congestion recovery procedures."            ::= { frPVCEndptEntry 13 }

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -