⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2287.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
                   application(5)       -- executable                   }       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The type of element that is part of the installed           application."       ::= { sysApplInstallElmtEntry 3 }   sysApplInstallElmtDate OBJECT-TYPE       SYNTAX      DateAndTime       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The date and time that this component was installed on           the system."       ::= { sysApplInstallElmtEntry 4 }   sysApplInstallElmtPath OBJECT-TYPE       SYNTAX      LongUtf8String       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The full directory path where this element is installed.           For example, the value would be '/opt/EMPuma/bin' for an           element installed in the directory '/opt/EMPuma/bin'.           Most application packages include information about the           elements contained in the package. In addition, elements           are typically installed in sub-directories under the           package installation directory.  In cases where the           element path names are not included in the package           information itself, the path can usually be determined           by a simple search of the sub-directories.  If the           element is not installed in that location and there is           no other information available to the agent implementation,           then the path is unknown and null is returned."       ::= { sysApplInstallElmtEntry 5}   sysApplInstallElmtSizeHigh OBJECT-TYPE       SYNTAX      Unsigned32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The installed file size in 2^32 byte blocks. This is           the size of the file on disk immediately after installation.           For example, for a file with a total size of 4,294,967,296           bytes, this variable would have a value of 1; for a file           with a total size of 4,294,967,295 bytes this variable           would be 0."       ::= { sysApplInstallElmtEntry 6 }   sysApplInstallElmtSizeLow OBJECT-TYPE       SYNTAX      Unsigned32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The installed file size modulo 2^32 bytes.  This is           the size of the file on disk immediately after installation.           For example, for a file with a total size of 4,294,967,296           bytes this variable would have a value of 0; for a file with           a total size of 4,294,967,295 bytes this variable would be           4,294,967,295."       ::= { sysApplInstallElmtEntry 7 }   sysApplInstallElmtRole  OBJECT-TYPE       SYNTAX      BITS {                   executable(0),                      -- An application may have one or                      -- more executable elements.  The rest of the                      -- bits have no meaning if the element is not                      -- executable.                   exclusive(1),                      -- Only one copy of an exclusive element may be                      -- running per invocation of the running                      -- application.                   primary(2),                      -- The primary executable.  An application can                      -- have one, and only one element that is designated                      -- as the primary executable.  The execution of                      -- this element constitutes an invocation of                      -- the application.  This is used by the agent                      -- implementation to determine the initiation of                      -- an application.  The primary executable must                      -- remain running long enough for the agent                      -- implementation to detect its presence.                   required(3),                      -- An application may have zero or more required                      -- elements. All required elements must be running                      -- in order for the application to be judged to be                      -- running and healthy.                   dependent(4),                      -- An application may have zero or more                      -- dependent elements. Dependent elements may                      -- not be running unless required elements are.                   unknown(5)                      -- Default value for the case when an operator                      -- has not yet assigned one of the other values.                      -- When set, bits 1, 2, 3, and 4 have no meaning.                   }       MAX-ACCESS  read-write       STATUS      current       DESCRIPTION           "An operator assigned value used in the determination of           application status. This value is used by the agent to           determine both the mapping of started processes to the           initiation of an application, as well as to allow for a           determination of application health. The default value,           unknown(5), is used when an operator has not yet assigned           one of the other values.  If unknown(5) is set, bits           1 - 4 have no meaning.  The possible values are:                   executable(0),                       An application may have one or                       more executable elements.  The rest of the                       bits have no meaning if the element is not                       executable.                   exclusive(1),                       Only one copy of an exclusive element may be                       running per invocation of the running                       application.                   primary(2),                       The primary executable.  An application can                       have one, and only one element that is designated                       as the primary executable.  The execution of                       this element constitutes an invocation of                       the application.  This is used by the agent                       implementation to determine the initiation of                       an application.  The primary executable must                       remain running long enough for the agent                       implementation to detect its presence.                   required(3),                       An application may have zero or more required                       elements. All required elements must be running                       in order for the application to be judged to be                       running and healthy.                   dependent(4),                       An application may have zero or more                       dependent elements. Dependent elements may                       not be running unless required elements are.                   unknown(5)                       Default value for the case when an operator                       has not yet assigned one of the other values.                       When set, bits 1, 2, 3, and 4 have no meaning.            sysApplInstallElmtRole is used by the agent implementation            in determining the initiation of an application, the            current state of a running application (see            sysApplRunCurrentState), when an application invocation is            no longer running, and the exit status of a terminated            application invocation (see sysApplPastRunExitState)."       DEFVAL { { unknown } }       ::= { sysApplInstallElmtEntry 8 }   sysApplInstallElmtModifyDate OBJECT-TYPE       SYNTAX      DateAndTime       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The date and time that this element was last modified.           Modification of the sysApplInstallElmtRole columnar           object does NOT constitute a modification of the element           itself and should not affect the value of this object."       ::= { sysApplInstallElmtEntry 9 }   sysApplInstallElmtCurSizeHigh OBJECT-TYPE       SYNTAX      Unsigned32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The current file size in 2^32 byte blocks.           For example, for a file with a total size of 4,294,967,296           bytes, this variable would have a value of 1; for a file           with a total size of 4,294,967,295 bytes this variable           would be 0."       ::= { sysApplInstallElmtEntry 10 }   sysApplInstallElmtCurSizeLow OBJECT-TYPE       SYNTAX      Unsigned32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The current file size modulo 2^32 bytes.           For example, for a file with a total size of 4,294,967,296           bytes this variable would have a value of 0; for a file with           a total size of 4,294,967,295 bytes this variable would be           4,294,967,295."       ::= { sysApplInstallElmtEntry 11 }   -- sysApplRun Group   -- This group models activity information for applications   -- that have been invoked and are either currently running,   -- or have previously run on the host system.  Likewise,   -- the individual elements of an invoked application are   -- also modeled to show currently running processes, and   -- processes that have run in the past.   -- sysApplRunTable   -- The sysApplRunTable contains the application instances   -- which are currently running on the host.  Since a single   -- application might be invoked multiple times, an entry is   -- added to this table for each INVOCATION of an application.   -- The table is indexed by sysApplInstallPkgIndex, sysApplRunIndex   -- to enable managers to easily locate all invocations of   -- a particular application package.   sysApplRunTable OBJECT-TYPE       SYNTAX      SEQUENCE OF SysApplRunEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "The table describes the applications which are executing           on the host.  Each time an application is invoked,           an entry is created in this table. When an application ends,           the entry is removed from this table and a corresponding                   entry is created in the SysApplPastRunTable.           A new entry is created in this table whenever the agent           implementation detects a new running process that is an           installed application element whose sysApplInstallElmtRole           designates it as being the application's primary executable           (sysApplInstallElmtRole = primary(2) ).           The table is indexed by sysApplInstallPkgIndex,           sysApplRunIndex to enable managers to easily locate all           invocations of a particular application package."       ::= { sysApplRun 1 }   sysApplRunEntry OBJECT-TYPE       SYNTAX      SysApplRunEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "The logical row describing an application which is           currently running on this host."       INDEX    { sysApplInstallPkgIndex, sysApplRunIndex }       ::= { sysApplRunTable   1 }   SysApplRunEntry ::= SEQUENCE {       sysApplRunIndex                         Unsigned32,       sysApplRunStarted                       DateAndTime,       sysApplRunCurrentState                  RunState   }   sysApplRunIndex OBJECT-TYPE       SYNTAX      Unsigned32 (1..'ffffffff'h)       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION           "Part of the index for this table. An arbitrary           integer used only for indexing purposes. Generally           monotonically increasing from 1 as new applications are           started on the host, it uniquely identifies application           invocations.           The numbering for this index increases by 1 for each           INVOCATION of an application, regardless of which           installed application package this entry represents a           running instance of.           An example of the indexing for a couple of entries is           shown below.                         :                    sysApplRunStarted.17.14                    sysApplRunStarted.17.63                    sysApplRunStarted.18.13                         :           In this example, the agent has observed 12 application           invocations when the application represented by entry 18           in the sysApplInstallPkgTable is invoked.  The next           invocation detected by the agent is an invocation of           installed application package 17.  Some time later,           installed application 17 is invoked a second time.           NOTE: this index is not intended to reflect a real-time           (wall clock time) ordering of application invocations;           it is merely intended to uniquely identify running           instances of applications.  Although the           sysApplInstallPkgIndex is included in the INDEX clause           for this table, it serves only to ease searching of           this table by installed application and does not           contribute to uniquely identifying table entries."       ::= { sysApplRunEntry 1 }   sysApplRunStarted OBJECT-TYPE       SYNTAX      DateAndTime       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The date and time that the application was started."       ::= { sysApplRunEntry 2 }   sysApplRunCurrentState OBJECT-TYPE       SYNTAX      RunState       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION           "The current state of the running application instance.           The possible values are running(1), runnable(2) but waiting           for a resource such as CPU, waiting(3) for an event,

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -