⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc3434.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 2 页
字号:
            This object may not be modified if the associated            hcAlarmStatus object is equal to active(1)."    ::= { hcAlarmEntry 9 }hcAlarmRisingThresholdValStatus OBJECT-TYPE    SYNTAX      HcValueStatus    MAX-ACCESS  read-create    STATUS      current    DESCRIPTION            "This object indicates the sign of the data for the rising            threshold, as defined by the hcAlarmRisingThresAbsValueLo            and hcAlarmRisingThresAbsValueHi objects, as described in            the HcValueStatus textual convention.            The enumeration 'valueNotAvailable(1)' is not allowed, and            the associated hcAlarmStatus object cannot be equal to            'active(1)' if this object is set to this value.            This object may not be modified if the associated            hcAlarmStatus object is equal to active(1)."    ::= { hcAlarmEntry 10 }hcAlarmFallingThreshAbsValueLo OBJECT-TYPE    SYNTAX      Unsigned32    MAX-ACCESS  read-create    STATUS      current    DESCRIPTION            "The lower 32 bits of the absolute value for threshold for            the sampled statistic.  The actual threshold value is            determined by the associated instances of the            hcAlarmFallingThreshAbsValueHi and            hcAlarmFallingThresholdValStatus objects, as follows:               ABS(threshold) = hcAlarmFallingThreshAbsValueLo +                     (hcAlarmFallingThreshAbsValueHi * 2^^32)            The absolute value of the threshold is adjusted as required,            as described in the HcValueStatus textual convention.  These            three object instances are conceptually combined to            represent the falling threshold for this entry.            When the current sampled value is less than or equal to this            threshold, and the value at the last sampling interval was            greater than this threshold, a single event will be            generated.  A single event will also be generated if the            first sample after this entry becomes valid is less than or            equal to this threshold and the associated            hcAlarmStartupAlarm is equal to fallingAlarm(2) or            risingOrFallingAlarm(3).            After a falling event is generated, another such event will            not be generated until the sampled value rises above this            threshold and reaches the threshold identified by the            hcAlarmRisingThreshAbsValueLo,            hcAlarmRisingThreshAbsValueHi, and            hcAlarmRisingThresholdValStatus objects.            This object may not be modified if the associated            hcAlarmStatus object is equal to active(1)."    ::= { hcAlarmEntry 11 }hcAlarmFallingThreshAbsValueHi OBJECT-TYPE    SYNTAX      Unsigned32    MAX-ACCESS  read-create    STATUS      current    DESCRIPTION            "The upper 32 bits of the absolute value for threshold for            the sampled statistic.  The actual threshold value is            determined by the associated instances of the            hcAlarmFallingThreshAbsValueLo and            hcAlarmFallingThresholdValStatus objects, as follows:               ABS(threshold) = hcAlarmFallingThreshAbsValueLo +                     (hcAlarmFallingThreshAbsValueHi * 2^^32)            The absolute value of the threshold is adjusted as required,            as described in the HcValueStatus textual convention.  These            three object instances are conceptually combined to            represent the falling threshold for this entry.            When the current sampled value is less than or equal to this            threshold, and the value at the last sampling interval was            greater than this threshold, a single event will be            generated.  A single event will also be generated if the            first sample after this entry becomes valid is less than or            equal to this threshold and the associated            hcAlarmStartupAlarm is equal to fallingAlarm(2) or            risingOrFallingAlarm(3).            After a falling event is generated, another such event will            not be generated until the sampled value rises above this            threshold and reaches the threshold identified by the            hcAlarmRisingThreshAbsValueLo,            hcAlarmRisingThreshAbsValueHi, and            hcAlarmRisingThresholdValStatus objects.            This object may not be modified if the associated            hcAlarmStatus object is equal to active(1)."    ::= { hcAlarmEntry 12 }hcAlarmFallingThresholdValStatus OBJECT-TYPE    SYNTAX      HcValueStatus    MAX-ACCESS  read-create    STATUS      current    DESCRIPTION            "This object indicates the sign of the data for the falling            threshold, as defined by the hcAlarmFallingThreshAbsValueLo            and hcAlarmFallingThreshAbsValueHi objects, as described in            the HcValueStatus textual convention.            The enumeration 'valueNotAvailable(1)' is not allowed, and            the associated hcAlarmStatus object cannot be equal to            'active(1)' if this object is set to this value.            This object may not be modified if the associated            hcAlarmStatus object is equal to active(1)."    ::= { hcAlarmEntry 13 }hcAlarmRisingEventIndex OBJECT-TYPE    SYNTAX      Integer32 (0..65535)    MAX-ACCESS  read-create    STATUS      current    DESCRIPTION            "The index of the eventEntry that is used when a rising            threshold is crossed.  The eventEntry identified by a            particular value of this index is the same as identified by            the same value of the eventIndex object.  If there is no            corresponding entry in the eventTable, then no association            exists.  In particular, if this value is zero, no associated            event will be generated, as zero is not a valid event index.            This object may not be modified if the associated            hcAlarmStatus object is equal to active(1)."    ::= { hcAlarmEntry 14 }hcAlarmFallingEventIndex OBJECT-TYPE    SYNTAX      Integer32 (0..65535)    MAX-ACCESS  read-create    STATUS      current    DESCRIPTION            "The index of the eventEntry that is used when a falling            threshold is crossed.  The eventEntry identified by a            particular value of this index is the same as identified by            the same value of the eventIndex object.  If there is no            corresponding entry in the eventTable, then no association            exists.  In particular, if this value is zero, no associated            event will be generated, as zero is not a valid event index.            This object may not be modified if the associated            hcAlarmStatus object is equal to active(1)."    ::= { hcAlarmEntry 15 }hcAlarmValueFailedAttempts OBJECT-TYPE    SYNTAX     Counter32    MAX-ACCESS read-only    STATUS     current    DESCRIPTION            "The number of times the associated hcAlarmVariable instance            was polled on behalf of this hcAlarmEntry, (while in the            active state) and the value was not available.  This counter            may experience a discontinuity if the agent restarts,            indicated by the value of sysUpTime."    ::= { hcAlarmEntry 16 }hcAlarmOwner OBJECT-TYPE    SYNTAX     OwnerString    MAX-ACCESS read-create    STATUS     current    DESCRIPTION            "The entity that configured this entry and is therefore            using the resources assigned to it."    ::= { hcAlarmEntry 17 }hcAlarmStorageType OBJECT-TYPE    SYNTAX     StorageType    MAX-ACCESS read-create    STATUS     current    DESCRIPTION            "The type of non-volatile storage configured for this entry.            If this object is equal to 'permanent(4)', then the            associated hcAlarmRisingEventIndex and            hcAlarmFallingEventIndex objects must be writable."    ::= { hcAlarmEntry 18 }hcAlarmStatus OBJECT-TYPE    SYNTAX      RowStatus    MAX-ACCESS  read-create    STATUS      current    DESCRIPTION            "The status of this row.            An entry MUST NOT exist in the active state unless all            objects in the entry have an appropriate value, as described            in the description clause for each writable object.            The hcAlarmStatus object may be modified if the associated            instance of this object is equal to active(1),            notInService(2), or notReady(3).  All other writable objects            may be modified if the associated instance of this object is            equal to notInService(2) or notReady(3)."    ::= { hcAlarmEntry 19 }---- Capabilities--hcAlarmCapabilities OBJECT-TYPE    SYNTAX      BITS {       hcAlarmCreation(0),       hcAlarmNvStorage(1)    }    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "An indication of the high capacity alarm capabilities            supported by this agent.            If the 'hcAlarmCreation' BIT is set, then this agent allows            NMS applications to create entries in the hcAlarmTable.            If the 'hcAlarmNvStorage' BIT is set, then this agent allows            entries in the hcAlarmTable which will be recreated after a            system restart, as controlled by the hcAlarmStorageType            object."    ::= { hcAlarmCapabilitiesObjects 1 }---- Notifications--hcAlarmNotifPrefix OBJECT IDENTIFIER      ::= { hcAlarmNotifications 0 }hcRisingAlarm NOTIFICATION-TYPE    OBJECTS  { hcAlarmVariable,               hcAlarmSampleType,               hcAlarmAbsValue,               hcAlarmValueStatus,               hcAlarmRisingThreshAbsValueLo,               hcAlarmRisingThreshAbsValueHi,               hcAlarmRisingThresholdValStatus,               hcAlarmRisingEventIndex }    STATUS   current    DESCRIPTION            "The SNMP notification that is generated when a high            capacity alarm entry crosses its rising threshold and            generates an event that is configured for sending SNMP            traps.            The hcAlarmEntry object instances identified in the OBJECTS            clause are from the entry that causes this notification to            be generated."     ::= { hcAlarmNotifPrefix 1 }hcFallingAlarm NOTIFICATION-TYPE    OBJECTS { hcAlarmVariable,              hcAlarmSampleType,              hcAlarmAbsValue,              hcAlarmValueStatus,              hcAlarmFallingThreshAbsValueLo,              hcAlarmFallingThreshAbsValueHi,              hcAlarmFallingThresholdValStatus,              hcAlarmFallingEventIndex }    STATUS    current    DESCRIPTION            "The SNMP notification that is generated when a high            capacity alarm entry crosses its falling threshold and            generates an event that is configured for sending SNMP            traps.            The hcAlarmEntry object instances identified in the OBJECTS            clause are from the entry that causes this notification to            be generated."     ::= { hcAlarmNotifPrefix 2 }---- Conformance Section--hcAlarmCompliances OBJECT IDENTIFIER ::= { hcAlarmConformance 1 }hcAlarmGroups      OBJECT IDENTIFIER ::= { hcAlarmConformance 2 }hcAlarmCompliance MODULE-COMPLIANCE    STATUS  current    DESCRIPTION            "Describes the requirements for conformance to the High            Capacity Alarm MIB."    MODULE  -- this module        MANDATORY-GROUPS {                           hcAlarmControlGroup,                           hcAlarmCapabilitiesGroup,                           hcAlarmNotificationsGroup                         }    MODULE RMON-MIB        MANDATORY-GROUPS { rmonEventGroup }    ::= { hcAlarmCompliances 1 }-- Object GroupshcAlarmControlGroup OBJECT-GROUP    OBJECTS {             hcAlarmInterval,             hcAlarmVariable,             hcAlarmSampleType,             hcAlarmAbsValue,             hcAlarmValueStatus,             hcAlarmStartupAlarm,             hcAlarmRisingThreshAbsValueLo,             hcAlarmRisingThreshAbsValueHi,             hcAlarmRisingThresholdValStatus,             hcAlarmFallingThreshAbsValueLo,             hcAlarmFallingThreshAbsValueHi,             hcAlarmFallingThresholdValStatus,             hcAlarmRisingEventIndex,             hcAlarmFallingEventIndex,             hcAlarmValueFailedAttempts,             hcAlarmOwner,             hcAlarmStorageType,             hcAlarmStatus    }    STATUS  current    DESCRIPTION            "A collection of objects used to configure entries for high            capacity alarm threshold monitoring purposes."    ::= { hcAlarmGroups 1 }hcAlarmCapabilitiesGroup OBJECT-GROUP    OBJECTS {             hcAlarmCapabilities    }    STATUS  current    DESCRIPTION            "A collection of objects used to indicate an agent's high            capacity alarm threshold monitoring capabilities."    ::= { hcAlarmGroups 2 }hcAlarmNotificationsGroup NOTIFICATION-GROUP    NOTIFICATIONS {            hcRisingAlarm,            hcFallingAlarm    }    STATUS  current    DESCRIPTION            "A collection of notifications to deliver information            related to a high capacity rising or falling threshold event            to a management application."    ::= { hcAlarmGroups 3 }END

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -