⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2670.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
        DESCRIPTION            "The number of 6.25 microsecond ticks in each upstream mini-             slot. Returns zero if the value is undefined or unknown.             See the associated conformance object for write             conditions and limitations."        REFERENCE            "DOCSIS Radio Frequency Interface Specification,             Section 6.1.2.4."        ::= { docsIfUpstreamChannelEntry 5 }docsIfUpChannelTxTimingOffset OBJECT-TYPE        SYNTAX      Unsigned32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "A measure of the current round trip time at the CM, or the             maximum round trip time seen by the CMTS.  Used for timing             of CM upstream transmissions to ensure synchronized             arrivals at the CMTS. Units are in terms of             (6.25 microseconds/64)."        REFERENCE            "DOCSIS Radio Frequency Interface Specification,             Section 6.5."        ::= { docsIfUpstreamChannelEntry 6 }docsIfUpChannelRangingBackoffStart OBJECT-TYPE        SYNTAX      Integer32 (0..16)        MAX-ACCESS  read-write        STATUS      current        DESCRIPTION            "The initial random backoff window to use when retrying             Ranging Requests. Expressed as a power of 2. A value of 16             at the CMTS indicates that a proprietary adaptive retry             mechanism is to be used. See the associated conformance             object for write conditions and limitations."        REFERENCE            "DOCSIS Radio Frequency Interface Specification,             Section 6.4.4."        ::= { docsIfUpstreamChannelEntry 7 }docsIfUpChannelRangingBackoffEnd OBJECT-TYPE        SYNTAX      Integer32 (0..16)        MAX-ACCESS  read-write        STATUS      current        DESCRIPTION            "The final random backoff window to use when retrying             Ranging Requests. Expressed as a power of 2. A value of 16             at the CMTS indicates that a proprietary adaptive retry             mechanism is to be used. See the associated conformance             object for write conditions and limitations."        REFERENCE            "DOCSIS Radio Frequency Interface Specification,             Section 6.4.4."        ::= { docsIfUpstreamChannelEntry 8 }docsIfUpChannelTxBackoffStart OBJECT-TYPE        SYNTAX      Integer32 (0..16)        MAX-ACCESS  read-write        STATUS      current        DESCRIPTION            "The initial random backoff window to use when retrying             transmissions. Expressed as a power of 2. A value of 16             at the CMTS indicates that a proprietary adaptive retry             mechanism is to be used. See the associated conformance             object for write conditions and limitations."        REFERENCE            "DOCSIS Radio Frequency Interface Specification,             Section 6.4.4."        ::= { docsIfUpstreamChannelEntry 9 }docsIfUpChannelTxBackoffEnd OBJECT-TYPE        SYNTAX      Integer32 (0..16)        MAX-ACCESS  read-write        STATUS      current        DESCRIPTION            "The final random backoff window to use when retrying             transmissions. Expressed as a power of 2. A value of 16             at the CMTS indicates that a proprietary adaptive retry             mechanism is to be used. See the associated conformance             object for write conditions and limitations."        REFERENCE            "DOCSIS Radio Frequency Interface Specification,             Section 6.4.4."        ::= { docsIfUpstreamChannelEntry 10 }-- The following table describes the attributes of each class of-- service.  The entries in this table are referenced from the-- docsIfServiceEntries.  They exist as a separate table in order to-- reduce redundant information in docsIfServiceTable.---- This table is implemented at both the CM and the CMTS.-- The CM need only maintain entries for the classes of service-- referenced by its docsIfServiceTable.--docsIfQosProfileTable OBJECT-TYPE        SYNTAX      SEQUENCE OF DocsIfQosProfileEntry        MAX-ACCESS  not-accessible        STATUS      current        DESCRIPTION            "Describes the attributes for each class of service."        ::= { docsIfBaseObjects 3 }docsIfQosProfileEntry OBJECT-TYPE        SYNTAX      DocsIfQosProfileEntry        MAX-ACCESS  not-accessible        STATUS      current        DESCRIPTION            "Describes the attributes for a single class of service.             If implemented as read-create in the Cable Modem             Termination System, creation of entries in this table is             controlled by the value of docsIfCmtsQosProfilePermissions.             If implemented as read-only, entries are created based             on information in REG-REQ MAC messages received from             Cable Modems (Cable Modem Termination System             implementation), or based on information extracted from             the TFTP option file (Cable Modem implementation).             In the Cable Modem Termination system, read-only entries             are removed if no longer referenced by             docsIfCmtsServiceTable.             An entry in this table must not be removed while it is             referenced by an entry in docsIfCmServiceTable (Cable Modem)             or docsIfCmtsServiceTable (Cable Modem Termination System).             An entry in this table should not be changeable while             it is referenced by an entry in docsIfCmtsServiceTable.             If this table is created automatically, there should only             be a single entry for each Class of Service. Multiple             entries with the same Class of Service parameters are not             recommended."        INDEX { docsIfQosProfIndex }        ::= { docsIfQosProfileTable 1 }DocsIfQosProfileEntry ::= SEQUENCE {            docsIfQosProfIndex                Integer32,            docsIfQosProfPriority             Integer32,            docsIfQosProfMaxUpBandwidth       Integer32,            docsIfQosProfGuarUpBandwidth      Integer32,            docsIfQosProfMaxDownBandwidth     Integer32,            docsIfQosProfMaxTxBurst           Integer32,            docsIfQosProfBaselinePrivacy      TruthValue,            docsIfQosProfStatus               RowStatus        }docsIfQosProfIndex OBJECT-TYPE        SYNTAX      Integer32 (1..16383)        MAX-ACCESS  not-accessible        STATUS      current        DESCRIPTION            "The index value which uniquely identifies an entry             in the docsIfQosProfileTable."        ::= { docsIfQosProfileEntry 1 }docsIfQosProfPriority  OBJECT-TYPE        SYNTAX      Integer32 (0..7)        MAX-ACCESS  read-create        STATUS      current        DESCRIPTION            "A relative priority assigned to this service when             allocating bandwidth. Zero indicates lowest priority;             and seven indicates highest priority.             Interpretation of priority is device-specific.             MUST NOT be changed while this row is active."        DEFVAL { 0 }        ::= { docsIfQosProfileEntry 2 }docsIfQosProfMaxUpBandwidth OBJECT-TYPE        SYNTAX      Integer32 (0..100000000)        MAX-ACCESS  read-create        STATUS      current        DESCRIPTION            "The maximum upstream bandwidth, in bits per second,             allowed for a service with this service class.             Zero if there is no restriction of upstream bandwidth.             MUST NOT be changed while this row is active."        DEFVAL { 0 }        ::= { docsIfQosProfileEntry 3 }docsIfQosProfGuarUpBandwidth OBJECT-TYPE        SYNTAX      Integer32 (0..100000000)        MAX-ACCESS  read-create        STATUS      current        DESCRIPTION            "Minimum guaranteed upstream bandwidth, in bits per second,             allowed for a service with this service class.             MUST NOT be changed while this row is active."        DEFVAL { 0 }        ::= { docsIfQosProfileEntry 4 }docsIfQosProfMaxDownBandwidth OBJECT-TYPE        SYNTAX      Integer32 (0..100000000)        MAX-ACCESS  read-create        STATUS      current        DESCRIPTION            "The maximum downstream bandwidth, in bits per second,             allowed for a service with this service class.             Zero if there is no restriction of downstream bandwidth.             MUST NOT be changed while this row is active."        DEFVAL { 0 }        ::= { docsIfQosProfileEntry 5 }docsIfQosProfMaxTxBurst OBJECT-TYPE        SYNTAX      Integer32 (0..255)        MAX-ACCESS  read-create        STATUS      current        DESCRIPTION            "The maximum number of mini-slots that may be requested             for a single upstream transmission.             A value of zero means there is no limit.             MUST NOT be changed while this row is active."        DEFVAL { 0 }        ::= { docsIfQosProfileEntry 6 }docsIfQosProfBaselinePrivacy  OBJECT-TYPE        SYNTAX      TruthValue        MAX-ACCESS  read-create        STATUS      current        DESCRIPTION            "Indicates whether Baseline Privacy is enabled for this             service class.             MUST NOT be changed while this row is active."        DEFVAL { false }        ::= { docsIfQosProfileEntry 7 }docsIfQosProfStatus OBJECT-TYPE        SYNTAX      RowStatus        MAX-ACCESS  read-create        STATUS      current        DESCRIPTION            "This is object is to used to create or delete rows in             this table.  This object MUST NOT be changed from active             while the row is referenced by the any entry in either             docsIfCmServiceTable (on the CM), or the             docsIfCmtsServiceTable (on the CMTS)."        ::= { docsIfQosProfileEntry 8 }docsIfSignalQualityTable OBJECT-TYPE        SYNTAX      SEQUENCE OF DocsIfSignalQualityEntry        MAX-ACCESS  not-accessible        STATUS      current        DESCRIPTION            "At the CM, describes the PHY signal quality of downstream             channels. At the CMTS, describes the PHY signal quality of             upstream channels. At the CMTS, this table may exclude             contention intervals."        ::= { docsIfBaseObjects 4 }docsIfSignalQualityEntry OBJECT-TYPE        SYNTAX      DocsIfSignalQualityEntry        MAX-ACCESS  not-accessible        STATUS      current        DESCRIPTION            "At the CM, describes the PHY characteristics of a             downstream channel. At the CMTS, describes the PHY signal             quality of an upstream channel.             An entry in this table exists for each ifEntry with an             ifType of docsCableUpstream(129) for Cable Modem Termination             Systems and docsCableDownstream(128) for Cable Modems."        INDEX { ifIndex }        ::= { docsIfSignalQualityTable 1 }DocsIfSignalQualityEntry ::= SEQUENCE {            docsIfSigQIncludesContention  TruthValue,            docsIfSigQUnerroreds          Counter32,            docsIfSigQCorrecteds          Counter32,            docsIfSigQUncorrectables      Counter32,            docsIfSigQSignalNoise         TenthdB,            docsIfSigQMicroreflections    Integer32,            docsIfSigQEqualizationData    OCTET STRING        }docsIfSigQIncludesContention OBJECT-TYPE        SYNTAX      TruthValue        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "true(1) if this CMTS includes contention intervals in             the counters in this table. Always false(2) for CMs."        REFERENCE            "DOCSIS Radio Frequency Interface specification,             Section 6.4.4"        ::= { docsIfSignalQualityEntry 1 }docsIfSigQUnerroreds OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "Codewords received on this channel without error.             This includes all codewords, whether or not they             were part of frames destined for this device."        REFERENCE            "DOCSIS Radio Frequency Interface specification,             Section 4.2.3 and 4.3.6"        ::= { docsIfSignalQualityEntry 2 }docsIfSigQCorrecteds OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "Codewords received on this channel with correctable             errors. This includes all codewords, whether or not             they were part of frames destined for this device."        REFERENCE            "DOCSIS Radio Frequency Interface specification,             Section 4.2.3 and 4.3.6"        ::= { docsIfSignalQualityEntry 3 }docsIfSigQUncorrectables OBJECT-TYPE        SYNTAX      Counter32        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "Codewords received on this channel with uncorrectable             errors. This includes all codewords, whether or not             they were part of frames destined for this device."        REFERENCE            "DOCSIS Radio Frequency Interface specification,             Section 4.2.3 and 4.3.6"        ::= { docsIfSignalQualityEntry 4 }docsIfSigQSignalNoise OBJECT-TYPE        SYNTAX      TenthdB        UNITS       "dB"        MAX-ACCESS  read-only        STATUS      current        DESCRIPTION            "Signal/Noise ratio as perceived for this channel.             At the CM, describes the Signal/Noise of the downstream             channel.  At the CMTS, describes the average Signal/Noise             of the upstream channel."        REFERENCE            "DOCSIS Radio Frequency Interface specification,             Table 2-1 and 2-2"        ::= { docsIfSignalQualityEntry 5 }docsIfSigQMicroreflections OBJECT-TYPE        SYNTAX      Integer32 (0..255)        UNITS       "dBc"

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -