⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1382.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
                          "Entries of x25CircuitTable."                  INDEX { x25CircuitIndex,                          x25CircuitChannel }                  ::= { x25CircuitTable 1 }          X25CircuitEntry ::= SEQUENCE {                  x25CircuitIndex                          IfIndexType,                  x25CircuitChannel                          INTEGER,                  x25CircuitStatus                          INTEGER,                  x25CircuitEstablishTime                          TimeTicks,                  x25CircuitDirection                          INTEGER,                  x25CircuitInOctets                          Counter,                  x25CircuitInPdus                          Counter,                  x25CircuitInRemotelyInitiatedResets                          Counter,                  x25CircuitInProviderInitiatedResets                          Counter,                  x25CircuitInInterrupts                          Counter,                  x25CircuitOutOctets                          Counter,                  x25CircuitOutPdus                          Counter,                  x25CircuitOutInterrupts                          Counter,                  x25CircuitDataRetransmissionTimeouts                          Counter,                  x25CircuitResetTimeouts                          Counter,                  x25CircuitInterruptTimeouts                          Counter,                  x25CircuitCallParamId                          OBJECT IDENTIFIER,                  x25CircuitCalledDteAddress                          X121Address,                  x25CircuitCallingDteAddress                          X121Address,                  x25CircuitOriginallyCalledAddress                          X121Address,                  x25CircuitDescr                          DisplayString                  }          x25CircuitIndex OBJECT-TYPE                  SYNTAX  IfIndexType                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The ifIndex value for the X.25 Interface."                  ::= { x25CircuitEntry 1 }          x25CircuitChannel OBJECT-TYPE                  SYNTAX  INTEGER (0..4095)                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The channel number for this circuit."                  ::= { x25CircuitEntry 2 }          x25CircuitStatus OBJECT-TYPE                  SYNTAX  INTEGER {               -- state table states                                  invalid (1),                                  closed (2),             -- (p1)                                  calling (3),            -- (p2,p3,p5)                                  open (4),               -- (p4)                                  clearing (5),           -- (p6,p7)                                  pvc (6),                                  pvcResetting (7),                                  startClear (8),         -- Close cmd                                  startPvcResetting (9),  -- Reset cmd                                  other (10)                          }                  ACCESS  read-write                  STATUS  mandatory                  DESCRIPTION                          "This object reports the current status of                          the circuit.                          An existing instance of this object can only                          be set to startClear, startPvcResetting, or                          invalid.  An instance with the value calling                          or open can only be set to startClear and                          that action will start clearing the circuit.                          An instance with the value PVC can only be                          set to startPvcResetting or invalid and that                          action resets the PVC or deletes the circuit                          respectively.  The values startClear or                          startPvcResetting will never be returned by                          an agent.  An attempt to set the status of                          an existing instance to a value other than                          one of these values will result in an error.                          A non-existing instance can be set to PVC to                          create a PVC if the implementation supports                          dynamic creation of PVCs.  Some                          implementations may only allow creation and                          deletion of PVCs if the interface is down.                          Since the instance identifier will supply                          the PLE index and the channel number,                          setting this object alone supplies                          sufficient information to create the                          instance.  All the DEFVAL clauses for the                          other objects of this table are appropriate                          for creating a PVC; PLEs creating entries                          for placed or accepted calls will use values                          appropriate for the call rather than the                          value of the DEFVAL clause.  Two managers                          trying to create the same PVC can determine                          from the return code which manager succeeded                          and which failed (the failing manager fails                          because it can not set a value of PVC for an                          existing object).                          An entry in the closed or invalid state may                          be deleted or reused at the agent's                          convence.  If the entry is kept in the                          closed state, the values of the parameters                          associated with the entry must be correct.                          Closed implies the values in the circuit                          table are correct.                          The value of invalid indicates the other                          values in the table are invalid.  Many                          agents may never return a value of invalid                          because they dynamically allocate and free                          unused table entries.  An agent for a                          statically configured systems can return                          invalid to indicate the entry has not yet                          been used so the counters contain no                          information."                  REFERENCE "See ISO 8208,                                  table 33 for (p<n>) state table"                  ::= { x25CircuitEntry 3 }          x25CircuitEstablishTime OBJECT-TYPE                  SYNTAX  TimeTicks                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The value of sysUpTime when the channel was                          associated with this circuit.  For outgoing                          SVCs, this is the time the first call packet                          was sent.  For incoming SVCs, this is the                          time the call indication was received.  For                          PVCs this is the time the PVC was able to                          pass data to a higher layer entity without                          loss of data."                  ::= { x25CircuitEntry 4 }          x25CircuitDirection OBJECT-TYPE                  SYNTAX  INTEGER {                                  incoming (1),                                  outgoing (2),                                  pvc (3)                          }                  ACCESS  read-write                  STATUS  mandatory                  DESCRIPTION                          "The direction of the call that established                          this circuit."                  REFERENCE "10733 direction"                  DEFVAL { pvc }                  ::= { x25CircuitEntry 5 }                          -- X25 Circuit data flow statistics          x25CircuitInOctets OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of octets of user data delivered                          to upper layer."                  REFERENCE "5.11 octetsReceivedCounter"                  ::= { x25CircuitEntry 6 }          x25CircuitInPdus OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of PDUs received for this                          circuit."                  REFERENCE "10733 5.11 dataPacketsReceived"                  ::= { x25CircuitEntry 7 }          x25CircuitInRemotelyInitiatedResets OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of Resets received for this                          circuit with cause code of DTE initiated."                  REFERENCE "10733 remotelyInitiatedResets"                  ::= { x25CircuitEntry 8 }          x25CircuitInProviderInitiatedResets OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of Resets received for this                          circuit with cause code other than DTE                          initiated."                  REFERENCE "10733 ProviderInitiatedResets"                  ::= { x25CircuitEntry 9 }          x25CircuitInInterrupts OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of interrupt packets received                          for this circuit."                  REFERENCE "10733 interruptPacketsReceived"                  ::= { x25CircuitEntry 10 }          x25CircuitOutOctets OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of octets of user data sent for                          this circuit."                  REFERENCE "10733 5.11 octetsSentCounter"                  ::= { x25CircuitEntry 11 }          x25CircuitOutPdus OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of PDUs sent for this circuit."                  REFERENCE "10733 5.11 dataPacketsSent"                  ::= { x25CircuitEntry 12 }          x25CircuitOutInterrupts OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of interrupt packets sent on                          this circuit."                  REFERENCE "10733 interruptPacketsSent"                  ::= { x25CircuitEntry 13 }                          -- X25 circuit timer statistics          x25CircuitDataRetransmissionTimeouts OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of times the T25 data                          retransmission timer expired for this                          circuit."                  REFERENCE "10733 5.11 dataRetransmissionTimerExpiries"                  ::= { x25CircuitEntry 14 }          x25CircuitResetTimeouts OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of times the T22 reset timer                          expired for this circuit."                  REFERENCE "10733 5.11 resetTimeouts"                  ::= { x25CircuitEntry 15 }          x25CircuitInterruptTimeouts OBJECT-TYPE                  SYNTAX  Counter                  ACCESS  read-only                  STATUS  mandatory                  DESCRIPTION                          "The number of times the T26 Interrupt timer                          expired for this circuit."                  REFERENCE "10733 interruptTimerExpiries"                  ::= { x25CircuitEntry 16 }          x25CircuitCallParamId OBJECT-TYPE                  SYNTAX  OBJECT IDENTIFIER                  ACCESS  read-write                  STATUS  mandatory                  DESCRIPTION                          "This identifies the instance of the                          x25CallParmIndex for the entry in the                          x25CallParmTable which contains the call                          parameters in use with this circuit.  The                          entry referenced must contain the values                          that are currently in use by the circuit                          rather than proposed values.  A value of                          NULL indicates the circuit is a PVC or is                          using all the default parameters."                  DEFVAL { {0 0} }                  ::= { x25CircuitEntry 17 }          x25CircuitCalledDteAddress OBJECT-TYPE                  SYNTAX  X121Address                  ACCESS  read-write                  STATUS  mandatory                  DESCRIPTION                          "For incoming calls, this is the called                          address from the call indication packet.                          For outgoing calls, this 

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -