📄 rfc1382.mib
字号:
"Entries of x25CircuitTable." INDEX { x25CircuitIndex, x25CircuitChannel } ::= { x25CircuitTable 1 } X25CircuitEntry ::= SEQUENCE { x25CircuitIndex IfIndexType, x25CircuitChannel INTEGER, x25CircuitStatus INTEGER, x25CircuitEstablishTime TimeTicks, x25CircuitDirection INTEGER, x25CircuitInOctets Counter, x25CircuitInPdus Counter, x25CircuitInRemotelyInitiatedResets Counter, x25CircuitInProviderInitiatedResets Counter, x25CircuitInInterrupts Counter, x25CircuitOutOctets Counter, x25CircuitOutPdus Counter, x25CircuitOutInterrupts Counter, x25CircuitDataRetransmissionTimeouts Counter, x25CircuitResetTimeouts Counter, x25CircuitInterruptTimeouts Counter, x25CircuitCallParamId OBJECT IDENTIFIER, x25CircuitCalledDteAddress X121Address, x25CircuitCallingDteAddress X121Address, x25CircuitOriginallyCalledAddress X121Address, x25CircuitDescr DisplayString } x25CircuitIndex OBJECT-TYPE SYNTAX IfIndexType ACCESS read-only STATUS mandatory DESCRIPTION "The ifIndex value for the X.25 Interface." ::= { x25CircuitEntry 1 } x25CircuitChannel OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-only STATUS mandatory DESCRIPTION "The channel number for this circuit." ::= { x25CircuitEntry 2 } x25CircuitStatus OBJECT-TYPE SYNTAX INTEGER { -- state table states invalid (1), closed (2), -- (p1) calling (3), -- (p2,p3,p5) open (4), -- (p4) clearing (5), -- (p6,p7) pvc (6), pvcResetting (7), startClear (8), -- Close cmd startPvcResetting (9), -- Reset cmd other (10) } ACCESS read-write STATUS mandatory DESCRIPTION "This object reports the current status of the circuit. An existing instance of this object can only be set to startClear, startPvcResetting, or invalid. An instance with the value calling or open can only be set to startClear and that action will start clearing the circuit. An instance with the value PVC can only be set to startPvcResetting or invalid and that action resets the PVC or deletes the circuit respectively. The values startClear or startPvcResetting will never be returned by an agent. An attempt to set the status of an existing instance to a value other than one of these values will result in an error. A non-existing instance can be set to PVC to create a PVC if the implementation supports dynamic creation of PVCs. Some implementations may only allow creation and deletion of PVCs if the interface is down. Since the instance identifier will supply the PLE index and the channel number, setting this object alone supplies sufficient information to create the instance. All the DEFVAL clauses for the other objects of this table are appropriate for creating a PVC; PLEs creating entries for placed or accepted calls will use values appropriate for the call rather than the value of the DEFVAL clause. Two managers trying to create the same PVC can determine from the return code which manager succeeded and which failed (the failing manager fails because it can not set a value of PVC for an existing object). An entry in the closed or invalid state may be deleted or reused at the agent's convence. If the entry is kept in the closed state, the values of the parameters associated with the entry must be correct. Closed implies the values in the circuit table are correct. The value of invalid indicates the other values in the table are invalid. Many agents may never return a value of invalid because they dynamically allocate and free unused table entries. An agent for a statically configured systems can return invalid to indicate the entry has not yet been used so the counters contain no information." REFERENCE "See ISO 8208, table 33 for (p<n>) state table" ::= { x25CircuitEntry 3 } x25CircuitEstablishTime OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of sysUpTime when the channel was associated with this circuit. For outgoing SVCs, this is the time the first call packet was sent. For incoming SVCs, this is the time the call indication was received. For PVCs this is the time the PVC was able to pass data to a higher layer entity without loss of data." ::= { x25CircuitEntry 4 } x25CircuitDirection OBJECT-TYPE SYNTAX INTEGER { incoming (1), outgoing (2), pvc (3) } ACCESS read-write STATUS mandatory DESCRIPTION "The direction of the call that established this circuit." REFERENCE "10733 direction" DEFVAL { pvc } ::= { x25CircuitEntry 5 } -- X25 Circuit data flow statistics x25CircuitInOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets of user data delivered to upper layer." REFERENCE "5.11 octetsReceivedCounter" ::= { x25CircuitEntry 6 } x25CircuitInPdus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PDUs received for this circuit." REFERENCE "10733 5.11 dataPacketsReceived" ::= { x25CircuitEntry 7 } x25CircuitInRemotelyInitiatedResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Resets received for this circuit with cause code of DTE initiated." REFERENCE "10733 remotelyInitiatedResets" ::= { x25CircuitEntry 8 } x25CircuitInProviderInitiatedResets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of Resets received for this circuit with cause code other than DTE initiated." REFERENCE "10733 ProviderInitiatedResets" ::= { x25CircuitEntry 9 } x25CircuitInInterrupts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of interrupt packets received for this circuit." REFERENCE "10733 interruptPacketsReceived" ::= { x25CircuitEntry 10 } x25CircuitOutOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of octets of user data sent for this circuit." REFERENCE "10733 5.11 octetsSentCounter" ::= { x25CircuitEntry 11 } x25CircuitOutPdus OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of PDUs sent for this circuit." REFERENCE "10733 5.11 dataPacketsSent" ::= { x25CircuitEntry 12 } x25CircuitOutInterrupts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of interrupt packets sent on this circuit." REFERENCE "10733 interruptPacketsSent" ::= { x25CircuitEntry 13 } -- X25 circuit timer statistics x25CircuitDataRetransmissionTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T25 data retransmission timer expired for this circuit." REFERENCE "10733 5.11 dataRetransmissionTimerExpiries" ::= { x25CircuitEntry 14 } x25CircuitResetTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T22 reset timer expired for this circuit." REFERENCE "10733 5.11 resetTimeouts" ::= { x25CircuitEntry 15 } x25CircuitInterruptTimeouts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the T26 Interrupt timer expired for this circuit." REFERENCE "10733 interruptTimerExpiries" ::= { x25CircuitEntry 16 } x25CircuitCallParamId OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-write STATUS mandatory DESCRIPTION "This identifies the instance of the x25CallParmIndex for the entry in the x25CallParmTable which contains the call parameters in use with this circuit. The entry referenced must contain the values that are currently in use by the circuit rather than proposed values. A value of NULL indicates the circuit is a PVC or is using all the default parameters." DEFVAL { {0 0} } ::= { x25CircuitEntry 17 } x25CircuitCalledDteAddress OBJECT-TYPE SYNTAX X121Address ACCESS read-write STATUS mandatory DESCRIPTION "For incoming calls, this is the called address from the call indication packet. For outgoing calls, this
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -