📄 rfc1304.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 3 页
字号:
              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "The addressing information for one of this                      entity's IP addresses."              INDEX   { ipOverSMDSIndex, ipOverSMDSAddress }              ::= { ipOverSMDSTable 1 }          IpOverSMDSEntry ::=              SEQUENCE {                 ipOverSMDSIndex                     INTEGER,                 ipOverSMDSAddress                     IpAddress,                 ipOverSMDSHA                     SMDSAddress,                 ipOverSMDSLISGA                     SMDSAddress,                 ipOverSMDSARPReq                     SMDSAddress                 }          ipOverSMDSIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The value of this object identifies the SIP port                      interface for which this entry contains management                      information.  The value of this object for a                      particular interface has the same value as the                      ifIndex object, defined in RFC 1156 and RFC 1213,                      for the same interface."              ::= { ipOverSMDSEntry 1 }          ipOverSMDSAddress OBJECT-TYPE               SYNTAX  IpAddress               ACCESS  read-only               STATUS  mandatory               DESCRIPTION                      "The IP address to which this entry's addressing                      information pertains."              ::= { ipOverSMDSEntry 2 }          ipOverSMDSHA OBJECT-TYPE              SYNTAX  SMDSAddress              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The SMDS Individual address of the IP station."              ::= { ipOverSMDSEntry 3 }          ipOverSMDSLISGA OBJECT-TYPE              SYNTAX  SMDSAddress              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The SMDS Group Address that has been configured                      to identify the SMDS Subscriber-Network Interfaces                      (SNIs) of all members of the Logical IP Subnetwork                      (LIS) connected to the network supporting SMDS."              ::= { ipOverSMDSEntry 4 }          ipOverSMDSARPReq OBJECT-TYPE              SYNTAX  SMDSAddress              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The SMDS address (individual or group) to which                      ARP Requests are to be sent."              ::= { ipOverSMDSEntry 5 }          -- The SMDS Carrier Selection group          -- This group is used as a place holder          -- for carrier selection objects.          smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5}          -- The SIP Error Log          -- Implementation of this group is mandatory          -- for all systems that implement SIP Level 3.          sipErrorLog OBJECT IDENTIFIER ::= { sip 6 }          sipL3PDUErrorTable OBJECT-TYPE              SYNTAX  SEQUENCE OF SipL3PDUErrorEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "A table that contains the latest occurrence of                      the following syntactical SIP L3PDU errors:                      - Destination Address Field Format Error,                      The following pertains to the 60 least significant                      bits of the 64 bit address field.  The 60 bits                      contained in the address subfield can be used to                      represent addresses up to 15 decimal digits.  Each                      decimal digit shall be encoded into four bits                      using Binary Coded Decimal (BCD), with the most                      significant digit occurring left-most.  If not all                      15 digits are required, then the remainder of this                      field shall be padded on the right with bits set                      to one.  An error is considered to have occurred:                      a).  if the first four bits of the address                      subfield are not BCD, OR b).  if the first four                      bits of the address subfield are populated with                      the country code value 0001, AND the 40 bits which                      follow are not Binary Coded Decimal (BCD) encoded                      values of the 10 digit addresses, OR the remaining                      16 least significant bits are not populated with                      1's, OR c).  if the address subfield is not                      correct according to another numbering plan which                      is dependent upon the carrier assigning the                      numbers and offering SMDS.                      - Source Address Field Format Error,                      The description of this parameter is the same as                      the description of the Destination Address Field                      Format Error.                      - Invalid BAsize Field Value,                      An error is considered to have occurred when the                      BAsize field of an SIP L3PDU contains a value less                      that 32, greater than 9220 octets without the                      CRC32 field present, greater than 9224 octets with                      the CRC32 field present, or not equal to a                      multiple of 4 octets,                      - Invalid Header Extension Length Field Value,                      An error is considered to have occurred when the                      Header Extension Length field value is not equal                      3.                      - Invalid Header Extension - Element Length,                      An error is considered to have occurred when the                      Header Extension - Element Length is greater than                      12.                      - Invalid Header Extension - Version Element                      Position, Length, or Value,                      An error is considered to have occurred when a                      Version element with Length=3, Type=0, and Value=1                      does not appear first within the Header Extension,                      or an element Type=0 appears somewhere other than                      within the first three octets in the Header                      Extension.                      - Invalid Header Extension - Carrier Selection                      Element Position, Length, Value or Format,                      An error is considered to have occurred when a                      Carrier Selection element does not appear second                      within the Header Extension, if the Element Type                      does not equal 1, the Element Length does not                      equal 4, 6, or 8, the Element Value field is not                      four BCD encoded decimal digits used in specifying                      the Carrier Identification Code (CIC), or the                      identified CIC code is invalid.                      - Header Extension PAD Error                      An error is considered to have occurred when the                      Header Extension PAD is 9 octets in length, or if                      the Header Extension PAD is greater than zero                      octets in length and the Header Extension PAD does                      not follow all Header Extension elements or does                      not begin with at least one octet of all zeros.                      - BEtag Mismatch Error,                      An error is considered to have occurred when the                      Beginning-End Tags in the SIP L3PDU header and                      trailer are not equal.                      - BAsize Field not equal to Length Field Error,                      An error is considered to have occurred when the                      value of the BAsize Field does not equal the value                      of the Length Field.                      - Incorrect Length Error, and                      An error is considered to have occurred when the                      the Length field value is not equal to the portion                      of the SIP L3PDU which extends from the                      Destination Address field up to and including the                      CRC32 field (if present) or up to and including                      the PAD field (if the CRC32 field is not present).                      As an optional check, an error is considered to                      have occurred when the length of a partially                      received SIP L3PDU exceeds the BAsize value.                      - MRI Timeout Error.                      An error is considered to have occurred when the                      elapsed time between receipt of BOM and                      corresponding EOM exceeds the value of the MRI                      (Message Receive Interval) for a particular                      transport signal format.                      An entry is indexed by interface number and error                      type, and contains Source Address, Destination                      Address and a timestamp. All these errors are                      counted in the sipL3Errors counter.  When                      sipL3PDUErrorTimeStamp is equal to zero, the                      SipL3PDUErrorEntry does not contain any valid                      information."              ::= { sipErrorLog 1 }          sipL3PDUErrorEntry  OBJECT-TYPE              SYNTAX SipL3PDUErrorEntry              ACCESS  not-accessible              STATUS  mandatory              DESCRIPTION                      "An entry in the service disagreement table."              INDEX   { sipL3PDUErrorIndex, sipL3PDUErrorType }              ::= { sipL3PDUErrorTable 1 }          SipL3PDUErrorEntry ::= SEQUENCE {              sipL3PDUErrorIndex                  INTEGER,              sipL3PDUErrorType                  INTEGER,              sipL3PDUErrorSA                  SMDSAddress,              sipL3PDUErrorDA                  SMDSAddress,              sipL3PDUErrorTimeStamp                  TimeTicks              }          sipL3PDUErrorIndex OBJECT-TYPE              SYNTAX  INTEGER (1..65535)              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The value of this object identifies the SIP port                      interface for which this entry contains management                      information.   The value of this object for a                      particular interface has the same value as the                      ifIndex object, defined in RFC 1156 and RFC 1213,                      for the same interface."              ::= { sipL3PDUErrorEntry 1 }          sipL3PDUErrorType OBJECT-TYPE              SYNTAX  INTEGER {                   erroredDAFieldFormat (1),                   erroredSAFieldFormat (2),                   invalidBAsizeFieldValue (3),                   invalidHdrExtLength (4),                   invalidHdrExtElementLength (5),                   invalidHdrExtVersionElementPositionLenthOrValue (6),           invalidHdrExtCarSelectElementPositionLenghtValueOrFormat (7),                   hePADError (8),                   beTagMismatch (9),                   baSizeFieldNotEqualToLengthField (10),                   incorrectLength (11),                   mriTimeout (12)              }              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The type of error."              ::= { sipL3PDUErrorEntry 2 }          sipL3PDUErrorSA OBJECT-TYPE              SYNTAX  SMDSAddress              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A rejected SMDS source address."              ::= { sipL3PDUErrorEntry 3 }          sipL3PDUErrorDA OBJECT-TYPE              SYNTAX  SMDSAddress              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "A rejected SMDS destination address."              ::= { sipL3PDUErrorEntry 4 }          sipL3PDUErrorTimeStamp OBJECT-TYPE              SYNTAX  TimeTicks              ACCESS  read-only              STATUS  mandatory              DESCRIPTION                      "The timestamp for the service disagreement.  The                      timestamp contains the value of sysUpTime at the                      latest occurrence of this type of service                      disagreement.  See textual description under                      sipL3PDUErrorTable for boundary conditions."              ::= { sipL3PDUErrorEntry 5 }          END

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -