⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1565.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
字号:
   APPLICATION-MIB DEFINITIONS ::= BEGIN   IMPORTS       OBJECT-TYPE, Counter32, Gauge32, MODULE-IDENTITY         FROM SNMPv2-SMI       mib-2         FROM RFC1213-MIB       DisplayString, TimeStamp, TEXTUAL-CONVENTION         FROM SNMPv2-TC       MODULE-COMPLIANCE, OBJECT-GROUP         FROM SNMPv2-CONF;   application MODULE-IDENTITY       LAST-UPDATED "9311280000Z"       ORGANIZATION "IETF Mail and Directory Management Working Group"       CONTACT-INFO         "        Ned Freed          Postal: Innosoft International, Inc.                  250 West First Street, Suite 240                  Claremont, CA  91711                  US             Tel: +1 909 624 7907             Fax: +1 909 621 5319          E-Mail: ned@innosoft.com"       DESCRIPTION         "The MIB module describing network service applications"       ::= { mib-2 27 }   -- Textual conventions   -- DistinguishedName [5] is used to refer to objects in the   -- directory.   DistinguishedName ::= TEXTUAL-CONVENTION       STATUS current       DESCRIPTION           "A Distinguished Name represented in accordance with            RFC1485."       SYNTAX DisplayString   -- The basic applTable contains a list of the application   -- entities.   applTable OBJECT-TYPE       SYNTAX SEQUENCE OF ApplEntry       MAX-ACCESS not-accessible       STATUS current       DESCRIPTION           "The table holding objects which apply to all different            kinds of applications providing network services."       ::= {application 1}   applEntry OBJECT-TYPE       SYNTAX ApplEntry       MAX-ACCESS not-accessible       STATUS current       DESCRIPTION         "An entry associated with a network service application."       INDEX {applIndex}       ::= {applTable 1}   ApplEntry ::= SEQUENCE {       applIndex           INTEGER,       applName           DisplayString,       applDirectoryName           DistinguishedName,       applVersion           DisplayString,       applUptime           TimeStamp,       applOperStatus           INTEGER,       applLastChange           TimeStamp,       applInboundAssociations           Gauge32,       applOutboundAssociations           Gauge32,       applAccumulatedInboundAssociations           Counter32,       applAccumulatedOutboundAssociations           Counter32,       applLastInboundActivity           TimeStamp,       applLastOutboundActivity           TimeStamp,       applRejectedInboundAssociations           Counter32,       applFailedOutboundAssociations           Counter32   }   applIndex OBJECT-TYPE       SYNTAX INTEGER (1..2147483647)       MAX-ACCESS not-accessible       STATUS current       DESCRIPTION         "An index to uniquely identify the network service          application."       ::= {applEntry 1}   applName OBJECT-TYPE       SYNTAX DisplayString       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The name the network service application chooses to be          known by."       ::= {applEntry 2}   applDirectoryName OBJECT-TYPE       SYNTAX DistinguishedName       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The Distinguished Name of the directory entry where          static information about this application is stored.          An empty string indicates that no information about          the application is available in the directory."       ::= {applEntry 3}   applVersion OBJECT-TYPE       SYNTAX DisplayString       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The version of network service application software."       ::= {applEntry 4}   applUptime OBJECT-TYPE       SYNTAX TimeStamp       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The value of sysUpTime at the time the network service          application was last initialized.  If the application was          last initialized prior to the last initialization of the          network management subsystem, then this object contains          a zero value."       ::= {applEntry 5}   applOperStatus OBJECT-TYPE       SYNTAX INTEGER {         up(1),         down(2),         halted(3),         congested(4),         restarting(5)       }       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "Indicates the operational status of the network service          application. 'down' indicates that the network service is          not available. 'running' indicates that the network service          is operational and available.  'halted' indicates that the          service is operational but not available.  'congested'          indicates that the service is operational but no additional          inbound associations can be accomodated.  'restarting'          indicates that the service is currently unavailable but is          in the process of restarting and will be available soon."       ::= {applEntry 6}   applLastChange OBJECT-TYPE       SYNTAX TimeStamp       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The value of sysUpTime at the time the network service          application entered its current operational state.  If          the current state was entered prior to the last          initialization of the local network management subsystem,          then this object contains a zero value."       ::= {applEntry 7}   applInboundAssociations OBJECT-TYPE       SYNTAX Gauge32       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The number of current associations to the network service          application, where it is the responder.  For dynamic single          threaded processes, this will be the number of application          instances."       ::= {applEntry 8}   applOutboundAssociations OBJECT-TYPE       SYNTAX Gauge32       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The number of current associations to the network service          application, where it is the initiator.  For dynamic single          threaded processes, this will be the number of application          instances."       ::= {applEntry 9}   applAccumulatedInboundAssociations OBJECT-TYPE       SYNTAX Counter32       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The total number of associations to the application entity          since application initialization, where it was the responder.          For  dynamic single threaded processes, this will be the          number of application instances."       ::= {applEntry 10}   applAccumulatedOutboundAssociations OBJECT-TYPE       SYNTAX Counter32       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The total number of associations to the application entity          since application initialization, where it was the initiator.          For dynamic single threaded processes, this will be the          number of application instances."       ::= {applEntry 11}   applLastInboundActivity OBJECT-TYPE       SYNTAX TimeStamp       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The value of sysUpTime at the time this application last          had an inbound association.  If the last association          occurred prior to the last initialization of the network          subsystem, then this object contains a zero value."       ::= {applEntry 12}   applLastOutboundActivity OBJECT-TYPE       SYNTAX TimeStamp       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The value of sysUpTime at the time this application last          had an outbound association.  If the last association          occurred prior to the last initialization of the network          subsystem, then this object contains a zero value."       ::= {applEntry 13}   applRejectedInboundAssociations OBJECT-TYPE       SYNTAX Counter32       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The total number of inbound associations the application          entity has rejected, since application initialization."       ::= {applEntry 14}   applFailedOutboundAssociations OBJECT-TYPE       SYNTAX Counter32       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The total number associations where the application entity          is initiator and association establishment has failed,          since application initialization."       ::= {applEntry 15}   -- The assocTable augments the information in the applTable   -- with information about associations.  Note that two levels   -- of compliance are specified below, depending on whether   -- association monitoring is mandated.   assocTable OBJECT-TYPE       SYNTAX SEQUENCE OF AssocEntry       MAX-ACCESS not-accessible       STATUS current       DESCRIPTION           "The table holding a set of all active application            associations."       ::= {application 2}   assocEntry OBJECT-TYPE       SYNTAX AssocEntry       MAX-ACCESS not-accessible       STATUS current       DESCRIPTION         "An entry associated with an association for a network          service application."       INDEX {applIndex, assocIndex}       ::= {assocTable 1}   AssocEntry ::= SEQUENCE {       assocIndex           INTEGER,       assocRemoteApplication           DisplayString,       assocApplicationProtocol           OBJECT IDENTIFIER,       assocApplicationType           INTEGER,       assocDuration           TimeStamp   }   assocIndex OBJECT-TYPE       SYNTAX INTEGER (1..2147483647)       MAX-ACCESS not-accessible       STATUS current       DESCRIPTION         "An index to uniquely identify each association for a network          service application."       ::= {assocEntry 1}   assocRemoteApplication OBJECT-TYPE       SYNTAX DisplayString       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The name of the system running remote network service          application.  For an IP-based application this should be          either a domain name or IP address.  For an OSI application          it should be the string encoded distinguished name of the          managed object.  For X.400(84) MTAs which do not have a          Distinguished Name, the RFC1327 [6] syntax          'mta in globalid' should be used."       ::= {assocEntry 2}   assocApplicationProtocol OBJECT-TYPE       SYNTAX OBJECT IDENTIFIER       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "An identification of the protocol being used for the          application.  For an OSI Application, this will be the          Application Context.  For Internet applications, the IANA          maintains a registry of the OIDs which correspond to          well-known applications.  If the application protocol is          not listed in the registry, an OID value of the form          {applTCPProtoID port} or {applUDProtoID port} are used for          TCP-based and UDP-based protocols, respectively. In either          case 'port' corresponds to the primary port number being          used by the protocol."       ::= {assocEntry 3}   assocApplicationType OBJECT-TYPE       SYNTAX INTEGER {           ua-initiator(1),           ua-responder(2),           peer-initiator(3),           peer-responder(4)}       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "This indicates whether the remote application is some type of          client making use of this network service (e.g. a User Agent)          or a server acting as a peer. Also indicated is whether the          remote end initiated an incoming connection to the network          service or responded to an outgoing connection made by the          local application."       ::= {assocEntry 4}   assocDuration OBJECT-TYPE       SYNTAX TimeStamp       MAX-ACCESS read-only       STATUS current       DESCRIPTION         "The value of sysUpTime at the time this association was          started.  If this association started prior to the last          initialization of the network subsystem, then this          object contains a zero value."       ::= {assocEntry 5}   -- Conformance information   applConformance OBJECT IDENTIFIER ::= {application 3}   applGroups      OBJECT IDENTIFIER ::= {applConformance 1}   applCompliances OBJECT IDENTIFIER ::= {applConformance 2}   -- Compliance statements   applCompliance MODULE-COMPLIANCE       STATUS current       DESCRIPTION         "The compliance statement for SNMPv2 entities          which implement the Network Services Monitoring MIB          for basic monitoring of network service applications."       MODULE  -- this module         MANDATORY-GROUPS {applGroup}       ::= {applCompliances 1}   assocCompliance MODULE-COMPLIANCE       STATUS current       DESCRIPTION         "The compliance statement for SNMPv2 entities which          implement the Network Services Monitoring MIB for basic          monitoring of network service applications and their          associations."       MODULE  -- this module         MANDATORY-GROUPS {applGroup, assocGroup}       ::= {applCompliances 2}   -- Units of conformance   applGroup OBJECT-GROUP       OBJECTS {         applName, applVersion, applUptime, applOperStatus,         applLastChange, applInboundAssociations,         applOutboundAssociations, applAccumulatedInboundAssociations,         applAccumulatedOutboundAssociations, applLastInboundActivity,         applLastOutboundActivity, applRejectedInboundAssociations,         applFailedOutboundAssociations}       STATUS current       DESCRIPTION         "A collection of objects providing basic monitoring of          network service applications."       ::= {applGroups 1}   assocGroup OBJECT-GROUP       OBJECTS {         assocRemoteApplication, assocApplicationProtocol,         assocApplicationType, assocDuration}       STATUS current       DESCRIPTION         "A collection of objects providing basic monitoring of          network service applications' associations."       ::= {applGroups 2}   -- OIDs of the form {applTCPProtoID port} are intended to be used   -- for TCP-based protocols that don't have OIDs assigned by other   -- means. {applUDPProtoID port} serves the same purpose for   -- UDP-based protocols. In either case 'port' corresponds to   -- the primary port number being used by the protocol. For example,   -- assuming no other OID is assigned for SMTP, an OID of   -- {applTCPProtoID 25} could be used, since SMTP is a TCP-based   -- protocol that uses port 25 as its primary port.   applTCPProtoID OBJECT IDENTIFIER ::= {application 4}   applUDPProtoID OBJECT IDENTIFIER ::= {application 5}   END

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -