⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2674.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
    STATUS      current    DESCRIPTION        "The Priority value determined for the received frame.        This value is equivalent to the priority indicated in        the tagged frame received, or one of the evaluated        priorities, determined according to the media-type.        For untagged frames received from Ethernet media, this        value is equal to the dot1dPortDefaultUserPriority value        for the ingress port.        For untagged frames received from non-Ethernet media,        this value is equal to the dot1dRegenUserPriority value        for the ingress port and media-specific user priority."    ::= { dot1dTrafficClassEntry 1 }dot1dTrafficClass OBJECT-TYPE    SYNTAX      INTEGER (0..7)    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION        "The Traffic Class the received frame is mapped to."    ::= { dot1dTrafficClassEntry 2 }-- --------------------------------------------------------------- Outbound Access Priority Table-- -------------------------------------------------------------dot1dPortOutboundAccessPriorityTable OBJECT-TYPE    SYNTAX      SEQUENCE OF Dot1dPortOutboundAccessPriorityEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION        "A table mapping Regenerated User Priority to Outbound        Access Priority.  This is a fixed mapping for all port        types, with two options for 802.5 Token Ring."    REFERENCE        "ISO/IEC 15802-3 Table 7-3"    ::= { dot1dPriority 4 }dot1dPortOutboundAccessPriorityEntry OBJECT-TYPE    SYNTAX      Dot1dPortOutboundAccessPriorityEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION        "Regenerated User Priority to Outbound Access Priority        mapping."    INDEX   { dot1dBasePort, dot1dRegenUserPriority }    ::= { dot1dPortOutboundAccessPriorityTable 1 }Dot1dPortOutboundAccessPriorityEntry ::=    SEQUENCE {        dot1dPortOutboundAccessPriority            INTEGER    }dot1dPortOutboundAccessPriority OBJECT-TYPE    SYNTAX      INTEGER (0..7)    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION        "The Outbound Access Priority the received frame is        mapped to."    ::= { dot1dPortOutboundAccessPriorityEntry 1 }-- --------------------------------------------------------------- the dot1dGarp group-- --------------------------------------------------------------- --------------------------------------------------------------- The GARP Port Table-- -------------------------------------------------------------dot1dPortGarpTable OBJECT-TYPE    SYNTAX      SEQUENCE OF Dot1dPortGarpEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION        "A table of GARP control information about every bridge        port.  This is indexed by dot1dBasePort."    ::= { dot1dGarp 1 }dot1dPortGarpEntry OBJECT-TYPE    SYNTAX      Dot1dPortGarpEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION        "GARP control information for a bridge port."    AUGMENTS { dot1dBasePortEntry }    ::= { dot1dPortGarpTable 1 }Dot1dPortGarpEntry ::=    SEQUENCE {        dot1dPortGarpJoinTime            TimeInterval,        dot1dPortGarpLeaveTime            TimeInterval,        dot1dPortGarpLeaveAllTime            TimeInterval    }dot1dPortGarpJoinTime OBJECT-TYPE    SYNTAX      TimeInterval    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION        "The GARP Join time, in centiseconds."    DEFVAL      { 20 }    ::= { dot1dPortGarpEntry 1 }dot1dPortGarpLeaveTime OBJECT-TYPE    SYNTAX      TimeInterval    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION        "The GARP Leave time, in centiseconds."    DEFVAL      { 60 }    ::= { dot1dPortGarpEntry 2 }dot1dPortGarpLeaveAllTime OBJECT-TYPE    SYNTAX      TimeInterval    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION        "The GARP LeaveAll time, in centiseconds."    DEFVAL      { 1000 }    ::= { dot1dPortGarpEntry 3 }-- --------------------------------------------------------------- The GMRP Port Configuration and Status Table-- -------------------------------------------------------------dot1dPortGmrpTable OBJECT-TYPE    SYNTAX      SEQUENCE OF Dot1dPortGmrpEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION        "A table of GMRP control and status information about        every bridge port.  Augments the dot1dBasePortTable."    ::= { dot1dGmrp 1 }dot1dPortGmrpEntry OBJECT-TYPE    SYNTAX      Dot1dPortGmrpEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION        "GMRP control and status information for a bridge port."    AUGMENTS { dot1dBasePortEntry }    ::= { dot1dPortGmrpTable 1 }Dot1dPortGmrpEntry ::=    SEQUENCE {        dot1dPortGmrpStatus            EnabledStatus,        dot1dPortGmrpFailedRegistrations            Counter32,        dot1dPortGmrpLastPduOrigin            MacAddress    }dot1dPortGmrpStatus OBJECT-TYPE    SYNTAX      EnabledStatus    MAX-ACCESS  read-write    STATUS      current    DESCRIPTION        "The administrative state of GMRP operation on this port. The        value enabled(1) indicates that GMRP is enabled on this port        in all VLANs as long as dot1dGmrpStatus is also enabled(1).        A value of disabled(2) indicates that GMRP is disabled on        this port in all VLANs: any GMRP packets received will        be silently discarded and no GMRP registrations will be        propagated from other ports. Setting this to a value of        enabled(1) will be stored by the agent but will only take        effect on the GMRP protocol operation if dot1dGmrpStatus        also indicates the value enabled(1).  This object affects        all GMRP Applicant and Registrar state machines on this        port.  A transition from disabled(2) to enabled(1) will        cause a reset of all GMRP state machines on this port."    DEFVAL      { enabled }    ::= { dot1dPortGmrpEntry 1 }dot1dPortGmrpFailedRegistrations OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION        "The total number of failed GMRP registrations, for any        reason, in all VLANs, on this port."    ::= { dot1dPortGmrpEntry 2 }dot1dPortGmrpLastPduOrigin OBJECT-TYPE    SYNTAX      MacAddress    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION        "The Source MAC Address of the last GMRP message        received on this port."    ::= { dot1dPortGmrpEntry 3 }-- ---------------------------------------------------------------  High Capacity Port Table for Transparent Bridges-- -------------------------------------------------------------dot1dTpHCPortTable OBJECT-TYPE    SYNTAX      SEQUENCE OF Dot1dTpHCPortEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION        "A table that contains information about every high        capacity port that is associated with this transparent        bridge."    ::= { dot1dTp 5 }dot1dTpHCPortEntry OBJECT-TYPE    SYNTAX      Dot1dTpHCPortEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION        "Statistics information for each high capacity port of a        transparent bridge."    INDEX   { dot1dTpPort }    ::= { dot1dTpHCPortTable 1 }Dot1dTpHCPortEntry ::=    SEQUENCE {        dot1dTpHCPortInFrames            Counter64,        dot1dTpHCPortOutFrames            Counter64,        dot1dTpHCPortInDiscards            Counter64    }dot1dTpHCPortInFrames OBJECT-TYPE    SYNTAX      Counter64    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION        "The number of frames that have been received by this        port from its segment.  Note that a frame received on        the interface corresponding to this port is only counted        by this object if and only if it is for a protocol being        processed by the local bridging function, including        bridge management frames."    REFERENCE        "ISO/IEC 15802-3 Section 14.6.1.1.3"    ::= { dot1dTpHCPortEntry 1 }dot1dTpHCPortOutFrames OBJECT-TYPE    SYNTAX      Counter64    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION        "The number of frames that have been transmitted by this        port to its segment.  Note that a frame transmitted on        the interface corresponding to this port is only counted        by this object if and only if it is for a protocol being        processed by the local bridging function, including        bridge management frames."    REFERENCE        "ISO/IEC 15802-3 Section 14.6.1.1.3"    ::= { dot1dTpHCPortEntry 2 }dot1dTpHCPortInDiscards OBJECT-TYPE    SYNTAX      Counter64    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION        "Count of valid frames that have been received by this        port from its segment which were discarded (i.e.,        filtered) by the Forwarding Process."    REFERENCE        "ISO/IEC 15802-3 Section 14.6.1.1.3"    ::= { dot1dTpHCPortEntry 3 }-- ------------------------------------------------------  Upper part of High Capacity Port Table for Transparent Bridges-- ----------------------------------------------------dot1dTpPortOverflowTable OBJECT-TYPE    SYNTAX      SEQUENCE OF Dot1dTpPortOverflowEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION        "A table that contains the most-significant bits of        statistics counters for ports that are associated with this        transparent bridge that are on high capacity interfaces, as        defined in the conformance clauses for this table. This table        is provided as a way to read 64-bit counters for agents which        support only SNMPv1.        Note that the reporting of most-significant and        least-significant counter bits separately runs the risk of        missing an overflow of the lower bits in the interval between        sampling. The manager must be aware of this possibility, even        within the same varbindlist, when interpreting the results of        a request or asynchronous notification."    ::= { dot1dTp 6 }dot1dTpPortOverflowEntry OBJECT-TYPE    SYNTAX      Dot1dTpPortOverflowEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION        "The most significant bits of statistics counters for a high        capacity interface of a transparent bridge. Each object is        associated with a corresponding object in dot1dTpPortTable        which indicates the least significant bits of the counter."    INDEX   { dot1dTpPort }    ::= { dot1dTpPortOverflowTable 1 }Dot1dTpPortOverflowEntry ::=    SEQUENCE {        dot1dTpPortInOverflowFrames            Counter32,        dot1dTpPortOutOverflowFrames            Counter32,        dot1dTpPortInOverflowDiscards            Counter32    }dot1dTpPortInOverflowFrames OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION        "The number of times the associated dot1dTpPortInFrames        counter has overflowed."    REFERENCE        "ISO/IEC 15802-3 Section 14.6.1.1.3"    ::= { dot1dTpPortOverflowEntry 1 }dot1dTpPortOutOverflowFrames OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION        "The number of times the associated dot1dTpPortOutFrames        counter has overflowed."    REFERENCE        "ISO/IEC 15802-3 Section 14.6.1.1.3"    ::= { dot1dTpPortOverflowEntry 2 }dot1dTpPortInOverflowDiscards OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION        "The number of times the associated        dot1dTpPortInDiscards counter has overflowed."    REFERENCE        "ISO/IEC 15802-3 Section 14.6.1.1.3"    ::= { dot1dTpPortOverflowEntry 3 }-- --------------------------------------------------------------- IEEE 802.1p MIB - Conformance Information-- -------------------------------------------------------------pBridgeConformance OBJECT IDENTIFIER ::= { pBridgeMIB 2 }pBridgeGroups OBJECT IDENTIFIER ::= { pBridgeConformance 1 }pBridgeCompliances OBJECT IDENTIFIER    ::= { pBridgeConformance 2 }-- --------------------------------------------------------------- units of conformance-- -------------------------------------------------------------pBridgeExtCapGroup OBJECT-GROUP    OBJECTS {

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -