⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1318.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
字号:
                    RFC1318-MIB DEFINITIONS ::= BEGIN                    IMPORTS                            Counter                                    FROM RFC1155-SMI                            transmission                                    FROM RFC1213-MIB                            OBJECT-TYPE                                    FROM RFC-1212;            -- this is the MIB module for Parallel-printer-like            -- hardware devices            para    OBJECT IDENTIFIER ::= { transmission 34 }            -- the generic Parallel-printer-like group            -- Implementation of this group is mandatory for all            -- systems that have Parallel-printer-like hardware            -- ports supporting higher level services such as            -- character streams            paraNumber OBJECT-TYPE                SYNTAX INTEGER                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "The number of ports (regardless of their current                    state) in the Parallel-printer-like port table."                ::= { para 1 }            -- the Parallel-printer-like Port table            paraPortTable OBJECT-TYPE                SYNTAX SEQUENCE OF ParaPortEntry                ACCESS not-accessible                STATUS mandatory                DESCRIPTION                    "A list of port entries.  The number of entries is                    given by the value of paraNumber."                ::= { para 2 }            paraPortEntry OBJECT-TYPE                SYNTAX ParaPortEntry                ACCESS not-accessible                STATUS mandatory                DESCRIPTION                    "Status and parameter values for a port."                INDEX { paraPortIndex }                ::= { paraPortTable 1 }            ParaPortEntry ::=                SEQUENCE {                    paraPortIndex                        INTEGER,                    paraPortType                        INTEGER,                    paraPortInSigNumber                        INTEGER,                    paraPortOutSigNumber                        INTEGER                }            paraPortIndex OBJECT-TYPE                SYNTAX INTEGER                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "A unique value for each port.  Its value ranges                    between 1 and the value of paraNumber.  By                    convention and if possible, hardware port numbers                    map directly to external connectors.  The value for                    each port must remain constant at least from one                    re-initialization of the network management agent to                    the next."                ::= { paraPortEntry 1 }            paraPortType OBJECT-TYPE                SYNTAX INTEGER {                    other(1),                    centronics(2),                    dataproducts(3)                }                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "The port's hardware type."                ::= { paraPortEntry 2 }            paraPortInSigNumber OBJECT-TYPE                SYNTAX INTEGER                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "The number of input signals for the port in the                    input signal table (paraPortInSigTable).  The table                    contains entries only for those signals the software                    can detect."                ::= { paraPortEntry 3 }            paraPortOutSigNumber OBJECT-TYPE                SYNTAX INTEGER                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "The number of output signals for the port in the                    output signal table (paraPortOutSigTable).  The                    table contains entries only for those signals the                    software can assert."                ::= { paraPortEntry 4 }            -- the Input Signal table            paraInSigTable OBJECT-TYPE                SYNTAX SEQUENCE OF ParaInSigEntry                ACCESS not-accessible                STATUS mandatory                DESCRIPTION                    "A list of port input control signal entries."                ::= { para 3 }            paraInSigEntry OBJECT-TYPE                SYNTAX ParaInSigEntry                ACCESS not-accessible                STATUS mandatory                DESCRIPTION                    "Input control signal status for a hardware port."                INDEX { paraInSigPortIndex, paraInSigName }                ::= { paraInSigTable 1 }            ParaInSigEntry ::=                SEQUENCE {                    paraInSigPortIndex                        INTEGER,                    paraInSigName                        INTEGER,                    paraInSigState                        INTEGER,                    paraInSigChanges                        Counter                }            paraInSigPortIndex OBJECT-TYPE                SYNTAX INTEGER                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "The value of paraPortIndex for the port to which                    this entry belongs."                ::= { paraInSigEntry 1 }            paraInSigName OBJECT-TYPE                SYNTAX INTEGER { power(1), online(2), busy(3),                                 paperout(4), fault(5) }                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "Identification of a hardware signal."                ::= { paraInSigEntry 2 }            paraInSigState OBJECT-TYPE                SYNTAX INTEGER { none(1), on(2), off(3) }                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "The current signal state."                ::= { paraInSigEntry 3 }            paraInSigChanges OBJECT-TYPE                SYNTAX Counter                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "The number of times the signal has changed from                    'on' to 'off' or from 'off' to 'on'."                ::= { paraInSigEntry 4 }            -- the Output Signal table            paraOutSigTable OBJECT-TYPE                SYNTAX SEQUENCE OF ParaOutSigEntry                ACCESS not-accessible                STATUS mandatory                DESCRIPTION                    "A list of port output control signal entries."                ::= { para 4 }            paraOutSigEntry OBJECT-TYPE                SYNTAX ParaOutSigEntry                ACCESS not-accessible                STATUS mandatory                DESCRIPTION                    "Output control signal status for a hardware port."                INDEX { paraOutSigPortIndex, paraOutSigName }                ::= { paraOutSigTable 1 }            ParaOutSigEntry ::=                SEQUENCE {                    paraOutSigPortIndex                        INTEGER,                    paraOutSigName                        INTEGER,                    paraOutSigState                        INTEGER,                    paraOutSigChanges                        Counter                }            paraOutSigPortIndex OBJECT-TYPE                SYNTAX INTEGER                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "The value of paraPortIndex for the port to which                    this entry belongs."                ::= { paraOutSigEntry 1 }            paraOutSigName OBJECT-TYPE                SYNTAX INTEGER { power(1), online(2), busy(3),                                 paperout(4), fault(5) }                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "Identification of a hardware signal."                ::= { paraOutSigEntry 2 }            paraOutSigState OBJECT-TYPE                SYNTAX INTEGER { none(1), on(2), off(3) }                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "The current signal state."                ::= { paraOutSigEntry 3 }            paraOutSigChanges OBJECT-TYPE                SYNTAX Counter                ACCESS read-only                STATUS mandatory                DESCRIPTION                    "The number of times the signal has changed from                    'on' to 'off' or from 'off' to 'on'."                ::= { paraOutSigEntry 4 }            END

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -