📄 rfc1515.mib
字号:
MAU-MIB DEFINITIONS ::= BEGIN IMPORTS Counter FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 mib-2 FROM RFC1213-MIB TRAP-TYPE FROM RFC-1215; snmpDot3MauMgt OBJECT IDENTIFIER ::= { mib-2 26 } -- References -- -- The following references are used throughout this MIB: -- -- [RFC 1213] -- refers to McCloghrie, K., and M. Rose, Editors, -- Management Information Base for Network Management -- of TCP/IP-based internets: MIB-II, STD 17, RFC 1213, -- Hughes LAN Systems, Performance Systems International, -- March 1991. -- -- [RFC 1368] -- refers to McMaster, D., and K. McCloghrie, Editors, -- Definitions of Managed Objects for IEEE 802.3 Repeater -- Devices, RFC 1368, SynOptics Communications, Hughes -- LAN Systems, October 1992. -- -- [IEEE 802.3 MAU Mgt] -- refers to IEEE P802.3p, 'Layer Management for 10 Mb/s -- Medium Access Unit (MAUs), Section 20,' Draft Supplement -- to ANSI/IEEE 802.3, Draft 5, 11 July 1992. -- MIB Groups -- -- The dot3RpMauBasicGroup is mandatory for MAUs attached to -- repeaters. -- The dot3IfMauBasicGroup is mandatory for MAUs attached to -- DTEs (interfaces). -- The dot3BroadMauBasicGroup is mandatory for broadband MAUs -- attached to DTEs. dot3RpMauBasicGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 1 } dot3IfMauBasicGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 2 } dot3BroadMauBasicGroup OBJECT IDENTIFIER ::= { snmpDot3MauMgt 3 } -- object identifiers for MAU types -- (see rpMauType and ifMauType for usage) dot3MauType OBJECT IDENTIFIER ::= { snmpDot3MauMgt 4 } dot3MauTypeAUI -- no internal MAU, view from AUI OBJECT IDENTIFIER ::= { dot3MauType 1 } dot3MauType10Base5 -- thick coax MAU (per 802.3 section 8) OBJECT IDENTIFIER ::= { dot3MauType 2 } dot3MauTypeFoirl -- FOIRL MAU (per 802.3 section 9.9) OBJECT IDENTIFIER ::= { dot3MauType 3 } dot3MauType10Base2 -- thin coax MAU (per 802.3 section 10) OBJECT IDENTIFIER ::= { dot3MauType 4 } dot3MauType10BaseT -- UTP MAU (per 802.3 section 14) OBJECT IDENTIFIER ::= { dot3MauType 5 } dot3MauType10BaseFP -- passive fiber MAU (per 802.3 section 16) OBJECT IDENTIFIER ::= { dot3MauType 6 } dot3MauType10BaseFB -- sync fiber MAU (per 802.3 section 17) OBJECT IDENTIFIER ::= { dot3MauType 7 } dot3MauType10BaseFL -- async fiber MAU (per 802.3 section 18) OBJECT IDENTIFIER ::= { dot3MauType 8 } dot3MauType10Broad36 -- broadband DTE MAU (per 802.3 section 11) -- note that 10BROAD36 MAUs can be attached to interfaces but -- not to repeaters OBJECT IDENTIFIER ::= { dot3MauType 9 } -- -- The Repeater MAU Basic Group -- -- Implementation of the Repeater MAU Basic Group is mandatory -- for MAUs attached to repeaters. -- -- The Basic Repeater MAU Table -- rpMauTable OBJECT-TYPE SYNTAX SEQUENCE OF RpMauEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of descriptive and status information about the MAU(s) attached to the ports of a repeater." ::= { dot3RpMauBasicGroup 1 } rpMauEntry OBJECT-TYPE SYNTAX RpMauEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the table, containing information about a single MAU." INDEX { rpMauGroupIndex, rpMauPortIndex, rpMauIndex } ::= { rpMauTable 1 } RpMauEntry ::= SEQUENCE { rpMauGroupIndex INTEGER, rpMauPortIndex INTEGER, rpMauIndex INTEGER, rpMauType OBJECT IDENTIFIER, rpMauStatus INTEGER, rpMauMediaAvailable INTEGER, rpMauMediaAvailableStateExits Counter, rpMauJabberState INTEGER, rpMauJabberingStateEnters Counter } rpMauGroupIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This variable uniquely identifies the repeater group containing the port to which the MAU described by this entry is connected." REFERENCE "Reference RFC1368, rptrGroupIndex." ::= { rpMauEntry 1 } rpMauPortIndex OBJECT-TYPE SYNTAX INTEGER (1..1024) ACCESS read-only STATUS mandatory DESCRIPTION "This variable uniquely identifies the repeater port within group rpMauGroupIndex to which the MAU described by this entry is connected." REFERENCE "Reference RFC 1368, rptrPortIndex." ::= { rpMauEntry 2 } rpMauIndex OBJECT-TYPE SYNTAX INTEGER (1..9) ACCESS read-only STATUS mandatory DESCRIPTION "This variable uniquely identifies the MAU connected to port rpMauPortIndex within group rpMauGroupIndex that is described by this entry." REFERENCE "Reference IEEE 802.3 MAU Mgt, 20.2.3.2, aMAUID." ::= { rpMauEntry 3 } rpMauType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "This object identifies the 10 Mb/s baseband MAU type. An initial set of MAU types are defined above. The assignment of OBJECT IDENTIFIERs to new types of MAUs is managed by the IANA. If the MAU type is unknown, the object identifier unknownMauType OBJECT IDENTIFIER ::= { 0 0 } is returned. Note that unknownMauType is a syntactically valid object identifier, and any conformant implementation of ASN.1 and the BER must be able to generate and recognize this value." REFERENCE "Reference IEEE 802.3 MAU Mgt, 20.2.3.2, aMAUType." ::= { rpMauEntry 4 } rpMauStatus OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), operational(3), standby(4), shutdown(5), reset(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The current state of the MAU. This object may be implemented as a read-only object by those agents and MAUs that do not implement software control of the MAU state. Some agents may not support setting the value of this object to some of the enumerated values. The value other(1) is returned if the MAU is in a state other than one of the states 2 through 6. The value unknown(2) is returned when the MAU's true state is unknown; for example, when it is being initialized. A MAU in the operational(3) state is fully functional, operates, and passes signals to its attached DTE or repeater port in accordance to its specification. A MAU in standby(4) state forces DI and CI and the media transmitter to idle. Standby(4) mode only applies to link type MAUs. The state of rpMauMediaAvailable is unaffected. A MAU in shutdown(5) state assumes the same condition on DI, CI, and the media transmitter as though it were powered down. The MAU may return other(1) value for the mauJabber and rpMauMediaAvailable objects when it is in this state. For an AUI, this state will remove power from the AUI. Setting this variable to the value reset(6) resets the MAU in the same manner as a power-off, power- on cycle of at least one-half second would. The agent is not required to return the value reset (6). Setting this variable to the value operational(3), standby(4), or shutdown(5) causes the MAU to assume the respective state except that setting a mixing-type MAU or an AUI to standby(4) will cause the MAU to enter the shutdown state." REFERENCE "Reference IEEE 802.3 MAU Mgt, 20.2.3.2, aMAUAdminState, and 20.2.3.3, acMAUAdminControl and acResetMAUAction." ::= { rpMauEntry 5 } rpMauMediaAvailable OBJECT-TYPE SYNTAX INTEGER { other(1), unknown(2), available(3), notAvailable(4), remoteFault(5), invalidSignal(6) } ACCESS read-only STATUS mandatory
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -