⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc1515.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 3 页
字号:
        MAU-MIB DEFINITIONS ::= BEGIN        IMPORTS            Counter                             FROM RFC1155-SMI            OBJECT-TYPE                         FROM RFC-1212            mib-2                               FROM RFC1213-MIB            TRAP-TYPE                           FROM RFC-1215;        snmpDot3MauMgt OBJECT IDENTIFIER ::= { mib-2 26 }        --                      References        --        -- The following references are used throughout this MIB:        --        -- [RFC 1213]        --    refers to McCloghrie, K., and M. Rose, Editors,        --    Management Information Base for Network Management        --    of TCP/IP-based internets: MIB-II, STD 17, RFC 1213,        --    Hughes LAN Systems, Performance Systems International,        --    March 1991.        --        -- [RFC 1368]        --    refers to McMaster, D.,  and K. McCloghrie, Editors,        --    Definitions of Managed Objects for IEEE 802.3 Repeater        --    Devices, RFC 1368, SynOptics Communications, Hughes        --    LAN Systems, October 1992.        --        -- [IEEE 802.3 MAU Mgt]        --    refers to IEEE P802.3p, 'Layer Management for 10 Mb/s        --    Medium Access Unit (MAUs), Section 20,' Draft Supplement        --    to ANSI/IEEE 802.3, Draft 5, 11 July 1992.        --                      MIB Groups        --        --   The dot3RpMauBasicGroup is mandatory for MAUs attached to        --     repeaters.        --   The dot3IfMauBasicGroup is mandatory for MAUs attached to        --     DTEs (interfaces).        --   The dot3BroadMauBasicGroup is mandatory for broadband MAUs        --     attached to DTEs.        dot3RpMauBasicGroup            OBJECT IDENTIFIER ::= { snmpDot3MauMgt 1 }        dot3IfMauBasicGroup            OBJECT IDENTIFIER ::= { snmpDot3MauMgt 2 }        dot3BroadMauBasicGroup            OBJECT IDENTIFIER ::= { snmpDot3MauMgt 3 }        -- object identifiers for MAU types        --  (see rpMauType and ifMauType for usage)        dot3MauType            OBJECT IDENTIFIER ::= { snmpDot3MauMgt 4 }        dot3MauTypeAUI        -- no internal MAU, view from AUI            OBJECT IDENTIFIER ::= { dot3MauType 1 }        dot3MauType10Base5    -- thick coax MAU (per 802.3 section 8)            OBJECT IDENTIFIER ::= { dot3MauType 2 }        dot3MauTypeFoirl      -- FOIRL MAU (per 802.3 section 9.9)            OBJECT IDENTIFIER ::= { dot3MauType 3 }        dot3MauType10Base2    -- thin coax MAU (per 802.3 section 10)            OBJECT IDENTIFIER ::= { dot3MauType 4 }        dot3MauType10BaseT    -- UTP MAU (per 802.3 section 14)            OBJECT IDENTIFIER ::= { dot3MauType 5 }        dot3MauType10BaseFP   -- passive fiber MAU (per 802.3 section 16)            OBJECT IDENTIFIER ::= { dot3MauType 6 }        dot3MauType10BaseFB   -- sync fiber MAU (per 802.3 section 17)            OBJECT IDENTIFIER ::= { dot3MauType 7 }        dot3MauType10BaseFL   -- async fiber MAU (per 802.3 section 18)            OBJECT IDENTIFIER ::= { dot3MauType 8 }        dot3MauType10Broad36  -- broadband DTE MAU (per 802.3 section 11)            -- note that 10BROAD36 MAUs can be attached to interfaces but            -- not to repeaters            OBJECT IDENTIFIER ::= { dot3MauType 9 }        --        --                    The Repeater MAU Basic Group        --        -- Implementation of the Repeater MAU Basic Group is mandatory        -- for MAUs attached to repeaters.        --        -- The Basic Repeater MAU Table        --        rpMauTable OBJECT-TYPE            SYNTAX    SEQUENCE OF RpMauEntry            ACCESS    not-accessible            STATUS    mandatory            DESCRIPTION                    "Table of descriptive and status information about                    the MAU(s) attached to the ports of a repeater."            ::= { dot3RpMauBasicGroup 1 }        rpMauEntry OBJECT-TYPE            SYNTAX    RpMauEntry            ACCESS    not-accessible            STATUS    mandatory            DESCRIPTION                    "An entry in the table, containing information                    about a single MAU."            INDEX    { rpMauGroupIndex, rpMauPortIndex, rpMauIndex }            ::= { rpMauTable 1 }        RpMauEntry ::=            SEQUENCE {                rpMauGroupIndex                    INTEGER,                rpMauPortIndex                    INTEGER,                rpMauIndex                    INTEGER,                rpMauType                    OBJECT IDENTIFIER,                rpMauStatus                    INTEGER,                rpMauMediaAvailable                    INTEGER,                rpMauMediaAvailableStateExits                    Counter,                rpMauJabberState                    INTEGER,                rpMauJabberingStateEnters                    Counter            }        rpMauGroupIndex OBJECT-TYPE            SYNTAX    INTEGER (1..1024)            ACCESS    read-only            STATUS    mandatory            DESCRIPTION                    "This variable uniquely identifies the repeater                    group containing the port to which the MAU                    described by this entry is connected."            REFERENCE                    "Reference RFC1368, rptrGroupIndex."            ::= { rpMauEntry 1 }        rpMauPortIndex OBJECT-TYPE            SYNTAX    INTEGER (1..1024)            ACCESS    read-only            STATUS    mandatory            DESCRIPTION                    "This variable uniquely identifies the repeater                    port within group rpMauGroupIndex to which the MAU                    described by this entry is connected."            REFERENCE                    "Reference RFC 1368, rptrPortIndex."            ::= { rpMauEntry 2 }        rpMauIndex OBJECT-TYPE            SYNTAX    INTEGER (1..9)            ACCESS    read-only            STATUS    mandatory            DESCRIPTION                    "This variable uniquely identifies the MAU                    connected to port rpMauPortIndex within group                    rpMauGroupIndex that is described by this entry."            REFERENCE                    "Reference IEEE 802.3 MAU Mgt, 20.2.3.2, aMAUID."            ::= { rpMauEntry 3 }        rpMauType OBJECT-TYPE            SYNTAX    OBJECT IDENTIFIER            ACCESS    read-only            STATUS    mandatory            DESCRIPTION                    "This object identifies the 10 Mb/s baseband MAU                    type.  An initial set of MAU types are defined                    above.  The assignment of OBJECT IDENTIFIERs to                    new types of MAUs is managed by the IANA.  If the                    MAU type is unknown, the object identifier                        unknownMauType OBJECT IDENTIFIER ::= { 0 0 }                    is returned.  Note that unknownMauType is a                    syntactically valid object identifier, and any                    conformant implementation of ASN.1 and the BER                    must be able to generate and recognize this                    value."            REFERENCE                    "Reference IEEE 802.3 MAU Mgt, 20.2.3.2,                    aMAUType."            ::= { rpMauEntry 4 }        rpMauStatus OBJECT-TYPE            SYNTAX    INTEGER {                          other(1),                          unknown(2),                          operational(3),                          standby(4),                          shutdown(5),                          reset(6)                      }            ACCESS    read-write            STATUS    mandatory            DESCRIPTION                    "The current state of the MAU.  This object may be                    implemented as a read-only object by those agents                    and MAUs that do not implement software control of                    the MAU state.  Some agents may not support                    setting the value of this object to some of the                    enumerated values.                    The value other(1) is returned if the MAU is in a                    state other than one of the states 2 through 6.                    The value unknown(2) is returned when the MAU's                    true state is unknown; for example, when it is                    being initialized.                    A MAU in the operational(3) state is fully                    functional, operates, and passes signals to its                    attached DTE or repeater port in accordance to its                    specification.                    A MAU in standby(4) state forces DI and CI and the                    media transmitter to idle.  Standby(4) mode only                    applies to link type MAUs.  The state of                    rpMauMediaAvailable is unaffected.                    A MAU in shutdown(5) state assumes the same                    condition on DI, CI, and the media transmitter as                    though it were powered down.  The MAU may return                    other(1) value for the mauJabber and                    rpMauMediaAvailable objects when it is in this                    state.  For an AUI, this state will remove power                    from the AUI.                    Setting this variable to the value reset(6) resets                    the MAU in the same manner as a power-off, power-                    on cycle of at least one-half second would.  The                    agent is not required to return the value reset                    (6).                    Setting this variable to the value operational(3),                    standby(4), or shutdown(5) causes the MAU to                    assume the respective state except that setting a                    mixing-type MAU or an AUI to standby(4) will cause                    the MAU to enter the shutdown state."                REFERENCE                    "Reference IEEE 802.3 MAU Mgt, 20.2.3.2,                    aMAUAdminState, and 20.2.3.3, acMAUAdminControl                    and acResetMAUAction."            ::= { rpMauEntry 5 }        rpMauMediaAvailable OBJECT-TYPE            SYNTAX    INTEGER {                          other(1),                          unknown(2),                          available(3),                          notAvailable(4),                          remoteFault(5),                          invalidSignal(6)                      }            ACCESS    read-only            STATUS    mandatory

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -