⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2108.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
               following two conditions.  Only one test need be               made.  a) The ActivityDuration is greater than               ShortEventMaxTime and less than ValidPacketMinTime               and the CollisionEvent signal is deasserted.  b)               The OctetCount is less than 64, the               ActivityDuration is greater than ShortEventMaxTime               and the CollisionEvent signal is deasserted.               ValidPacketMinTime is greater than or equal to 552               bit times and less than 565 bit times.               An event whose length is greater than 74 bit times               but less than 82 bit times shall increment either               the shortEvents counter or the runts counter but               not both.  A CarrierEvent greater than or equal to               552 bit times but less than 565 bit times may or               may not be counted as a runt.               ValidPacketMinTime has tolerances included to               provide for circuit losses between a conformance               test point at the AUI and the measurement point               within the state machine.               Runts usually indicate collision fragments, a               normal network event.  In certain situations               associated with large diameter networks a               percentage of collision fragments may exceed               ValidPacketMinTime.               A discontinuity may occur in the value               when the value of object               rptrMonitorPortLastChange changes.               The approximate minimum time for rollover of this               counter is 16 hours in a 10Mb/s repeater."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.3.1.10, aRunts."       ::= { rptrMonitorPortEntry 9 }   rptrMonitorPortCollisions OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "For a clause 9 repeater, this counter is               incremented by one for any CarrierEvent signal               on any port for which the CollisionEvent signal               on this port is asserted.  For a clause 27               repeater port the counter increments on entering               the Collision Count Increment state of the               partition state diagram (fig 27-8 of               [IEEE 802.3 Std]).               A discontinuity may occur in the value               when the value of object               rptrMonitorPortLastChange changes.               The approximate minimum time for rollover of this               counter is 16 hours in a 10Mb/s repeater."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.3.1.11, aCollisions."       ::= { rptrMonitorPortEntry 10 }   rptrMonitorPortLateEvents OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "For a clause 9 repeater port, this counter is               incremented by one for each CarrierEvent               on this port in which the CollIn(X)               variable transitions to the value SQE (Ref:               9.6.6.2, IEEE 802.3 Std) while the               ActivityDuration is greater than the               LateEventThreshold.  For a clause 27 repeater               port, this counter is incremented by one on               entering the Collision Count Increment state               of the  partition state diagram (fig 27-8)               while the  ActivityDuration is greater than               the LateEvent- Threshold.  Such a CarrierEvent               is counted twice, as both a collision and as a               lateEvent.               The LateEventThreshold is greater than 480 bit               times and less than 565 bit times.               LateEventThreshold has tolerances included to               permit an implementation to build a single               threshold to serve as both the LateEventThreshold               and ValidPacketMinTime threshold.               A discontinuity may occur in the value               when the value of object               rptrMonitorPortLastChange changes.               The approximate minimum time for rollover of this               counter is 81 hours in a 10Mb/s repeater."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.3.1.12, aLateEvents."       ::= { rptrMonitorPortEntry 11 }   rptrMonitorPortVeryLongEvents OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "For a clause 9 repeater port, this counter               is incremented by one for each CarrierEvent               whose ActivityDuration is greater than the               MAU Jabber Lockup Protection timer TW3               (Ref: 9.6.1 & 9.6.5, IEEE 802.3 Std).               For a clause 27 repeater port, this counter               is incremented by one on entry to the               Rx Jabber state of the receiver timer state               diagram (fig 27-7).  Other counters may               be incremented as appropriate.               A discontinuity may occur in the value               when the value of object               rptrMonitorPortLastChange changes."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.3.1.13, aVeryLongEvents."       ::= { rptrMonitorPortEntry 12 }   rptrMonitorPortDataRateMismatches OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "This counter is incremented by one for each               frame received by this port that meets all               of the conditions required by only one of the               following two measurement methods:               Measurement method A:  1) The CollisionEvent               signal is not asserted (10Mb/s operation) or               the Collision Count Increment state of the               partition state diagram (fig 27-8 of               [IEEE 802.3 Std]) has not been entered               (100Mb/s operation).  2) The ActivityDuration               is greater than ValidPacketMinTime.  3) The               frequency (data rate) is detectably mismatched               from the local transmit frequency.               Measurement method B:  1) The CollisionEvent               signal is not asserted (10Mb/s operation)               or the Collision Count Increment state of the               partition state diagram (fig 27-8 of               [IEEE 802.3 Std]) has not been entered               (100Mb/s operation).  2) The OctetCount is               greater than 63.  3) The frequency (data               rate) is detectably mismatched from the local               transmit frequency.  The exact degree of               mismatch is vendor specific and is to be               defined by the vendor for conformance testing.               When this event occurs, other counters whose               increment conditions were satisfied may or may not               also be incremented, at the implementor's               discretion.  Whether or not the repeater was able               to maintain data integrity is beyond the scope of               this standard.               A discontinuity may occur in the value               when the value of object               rptrMonitorPortLastChange changes."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.3.1.14, aDataRateMismatches."       ::= { rptrMonitorPortEntry 13 }   rptrMonitorPortAutoPartitions OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "This counter is incremented by one for               each time the repeater has automatically               partitioned this port.               The conditions that cause a clause 9               repeater port to partition are specified in               the partition state diagram in clause 9 of               [IEEE 802.3 Std].  They are not differentiated               here.  A clause 27 repeater port partitions               on entry to the Partition Wait state of the               partition state diagram (fig 27-8 in               [IEEE 802.3 Std]).               A discontinuity may occur in the value               when the value of object               rptrMonitorPortLastChange changes."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.3.1.15, aAutoPartitions."       ::= { rptrMonitorPortEntry 14 }   rptrMonitorPortTotalErrors OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The total number of errors which have occurred on               this port.  This counter is the summation of the               values of other error counters (for the same               port), namely:                   rptrMonitorPortFCSErrors,                   rptrMonitorPortAlignmentErrors,                   rptrMonitorPortFrameTooLongs,                   rptrMonitorPortShortEvents,                   rptrMonitorPortLateEvents,                   rptrMonitorPortVeryLongEvents,                   rptrMonitorPortDataRateMismatches, and                   rptrMonitorPortSymbolErrors.               This counter is redundant in the sense that it is               the summation of information already available               through other objects.  However, it is included               specifically because the regular retrieval of this               object as a means of tracking the health of a port               provides a considerable optimization of network               management traffic over the otherwise necessary               retrieval of the summed counters.               Note that rptrMonitorPortRunts is not included               in this total; this is because runts usually               indicate collision fragments, a normal network               event.               A discontinuity may occur in the value               when the value of object               rptrMonitorPortLastChange changes."       ::= { rptrMonitorPortEntry 15 }   rptrMonitorPortLastChange OBJECT-TYPE       SYNTAX      TimeStamp       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "The value of sysUpTime when the last of               the following occurred:                 1) the agent cold- or warm-started;                 2) the row for the port was created                    (such as when a device or module was added                     to the system); or                 3) any condition that would cause one of                    the counters for the row to experience                    a discontinuity."       ::= { rptrMonitorPortEntry 16 }   rptrMonitor100PortTable OBJECT-TYPE       SYNTAX      SEQUENCE OF RptrMonitor100PortEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION               "Table of additional performance and error               statistics for 100Mb/s ports, above and               beyond those parameters that apply to both               10 and 100Mbps ports.  Entries exist only for               ports attached to 100Mbps repeaters.               The columnar object rptrMonitorPortLastChange               is used to indicate possible discontinuities               of counter type columnar objects in this table."       ::= { rptrMonitorPortInfo 2 }   rptrMonitor100PortEntry OBJECT-TYPE       SYNTAX      RptrMonitor100PortEntry       MAX-ACCESS  not-accessible       STATUS      current       DESCRIPTION               "An entry in the table, containing performance               and error statistics for a single 100Mb/s port."       INDEX    { rptrMonitorPortGroupIndex, rptrMonitorPortIndex }       ::= { rptrMonitor100PortTable 1 }   RptrMonitor100PortEntry ::=       SEQUENCE {           rptrMonitorPortIsolates               Counter32,           rptrMonitorPortSymbolErrors               Counter32,           rptrMonitorPortUpper32Octets               Counter32,           rptrMonitorPortHCReadableOctets               Counter64       }   rptrMonitorPortIsolates OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "This counter is incremented by one each time that               the repeater port automatically isolates as a               consequence of false carrier events.  The conditions               which cause a port to automatically isolate are               defined by the transition from the False Carrier               state to the Link Unstable state of the carrier               integrity state diagram (figure 27-9)               [IEEE 802.3 Standard].               Note:  Isolates do not affect the value of               the PortOperStatus object.               A discontinuity may occur in the value               when the value of object               rptrMonitorPortLastChange changes."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.3.1.16, aIsolates."       ::= { rptrMonitor100PortEntry 1 }   rptrMonitorPortSymbolErrors OBJECT-TYPE       SYNTAX      Counter32       MAX-ACCESS  read-only       STATUS      current       DESCRIPTION               "This counter is incremented by one each time when               valid length packet was received at the port and               there was at least one occurrence of an invalid               data symbol. This can increment only once per valid               carrier event. A collision presence at any port of               the repeater containing port N, will not cause this               attribute to increment.               A discontinuity may occur in the value               when the value of object               rptrMonitorPortLastChange changes.

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -