⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2108.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
   SNMP-REPEATER-MIB DEFINITIONS ::= BEGIN   IMPORTS       Counter32, Counter64, Integer32, Gauge32, TimeTicks,       OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, mib-2           FROM SNMPv2-SMI       TimeStamp, DisplayString, MacAddress, TEXTUAL-CONVENTION,       RowStatus, TestAndIncr           FROM SNMPv2-TC       OBJECT-GROUP, MODULE-COMPLIANCE           FROM SNMPv2-CONF       OwnerString           FROM IF-MIB;   snmpRptrMod MODULE-IDENTITY       LAST-UPDATED    "9609140000Z"       ORGANIZATION    "IETF HUB MIB Working Group"       CONTACT-INFO           "WG E-mail: hubmib@hprnd.rose.hp.com                Chair: Dan Romascanu               Postal: Madge Networks (Israel) Ltd.                       Atidim Technology Park, Bldg. 3                       Tel Aviv 61131, Israel                  Tel: 972-3-6458414, 6458458                  Fax: 972-3-6487146               E-mail: dromasca@madge.com               Editor: Kathryn de Graaf               Postal: 3Com Corporation                       118 Turnpike Rd.                       Southborough, MA 01772 USA                  Tel: (508)229-1627                  Fax: (508)490-5882               E-mail: kdegraaf@isd.3com.com"       DESCRIPTION           "Management information for 802.3 repeaters.           The following references are used throughout           this MIB module:           [IEEE 802.3 Std]               refers to IEEE 802.3/ISO 8802-3 Information               processing systems - Local area networks -               Part 3: Carrier sense multiple access with               collision detection (CSMA/CD) access method               and physical layer specifications (1993).           [IEEE 802.3 Mgt]               refers to IEEE 802.3u-1995, '10 Mb/s &               100 Mb/s Management, Section 30,'               Supplement to ANSI/IEEE 802.3.           The following terms are used throughout this           MIB module.  For complete formal definitions,           the IEEE 802.3 standards should be consulted           wherever possible:           System - A managed entity compliant with this           MIB, and incorporating at least one managed           802.3 repeater.           Chassis - An enclosure for one managed repeater,           part of a managed repeater, or several managed           repeaters.  It typically contains an integral           power supply and a variable number of available           module slots.           Repeater-unit - The portion of the repeater set           that is inboard of the physical media interfaces.           The physical media interfaces (MAUs, AUIs) may be           physically separated from the repeater-unit, or           they may be integrated into the same physical           package.           Trivial repeater-unit - An isolated port that can           gather statistics.           Group - A recommended, but optional, entity           defined by the IEEE 802.3 management standard,           in order to support a modular numbering scheme.           The classical example allows an implementor to           represent field-replaceable units as groups of           ports, with the port numbering matching the           modular hardware implementation.           System interconnect segment - An internal           segment allowing interconnection of ports           belonging to different physical entities           into the same logical manageable repeater.           Examples of implementation might be           backplane busses in modular hubs, or           chaining cables in stacks of hubs.           Stack - A scalable system that may include           managed repeaters, in which modularity is           achieved by interconnecting a number of           different chassis.           Module - A building block in a modular           chassis.  It typically maps into one 'slot';           however, the range of configurations may be           very large, with several modules entering           one slot, or one module covering several           slots.           "       REVISION "9309010000Z"       DESCRIPTION           "Published as RFC 1516"       REVISION "9210010000Z"       DESCRIPTION           "Published as RFC 1368"       ::= { snmpDot3RptrMgt 5 }   snmpDot3RptrMgt OBJECT IDENTIFIER ::= { mib-2 22 }   OptMacAddr ::= TEXTUAL-CONVENTION       DISPLAY-HINT    "1x:"       STATUS          current       DESCRIPTION           "Either a 6 octet address in the `canonical'           order defined by IEEE 802.1a, i.e., as if it           were transmitted least significant bit first           if a value is available or a zero length string."       REFERENCE           "See MacAddress in SNMPv2-TC. The only difference           is that a zero length string is allowed as a value           for OptMacAddr and not for MacAddress."       SYNTAX OCTET STRING (SIZE (0 | 6))   -- Basic information at the repeater, group, and port level.   rptrBasicPackage       OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 1 }     rptrRptrInfo           OBJECT IDENTIFIER ::= { rptrBasicPackage 1 }     rptrGroupInfo           OBJECT IDENTIFIER ::= { rptrBasicPackage 2 }     rptrPortInfo           OBJECT IDENTIFIER ::= { rptrBasicPackage 3 }     rptrAllRptrInfo           OBJECT IDENTIFIER ::= { rptrBasicPackage 4 }   -- Monitoring information at the repeater, group, and port level.   rptrMonitorPackage       OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 2 }     rptrMonitorRptrInfo           OBJECT IDENTIFIER ::= { rptrMonitorPackage 1 }     rptrMonitorGroupInfo           OBJECT IDENTIFIER ::= { rptrMonitorPackage 2 }     rptrMonitorPortInfo           OBJECT IDENTIFIER ::= { rptrMonitorPackage 3 }     rptrMonitorAllRptrInfo           OBJECT IDENTIFIER ::= { rptrMonitorPackage 4 }   -- Address tracking information at the repeater, group,   -- and port level.   rptrAddrTrackPackage       OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 3 }     rptrAddrTrackRptrInfo           OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 1 }     rptrAddrTrackGroupInfo           -- this subtree is currently unused           OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 2 }     rptrAddrTrackPortInfo           OBJECT IDENTIFIER ::= { rptrAddrTrackPackage 3 }   -- TopN information.   rptrTopNPackage           OBJECT IDENTIFIER ::= { snmpDot3RptrMgt 4 }     rptrTopNRptrInfo           -- this subtree is currently unused           OBJECT IDENTIFIER ::= { rptrTopNPackage 1 }     rptrTopNGroupInfo           -- this subtree is currently unused           OBJECT IDENTIFIER ::= { rptrTopNPackage 2 }     rptrTopNPortInfo           OBJECT IDENTIFIER ::= { rptrTopNPackage 3 }   -- Old version of basic information at the repeater level.   --   -- In a system containing a single managed repeater,   -- configuration, status, and control objects for the overall   -- repeater.   --   -- The objects contained under the rptrRptrInfo subtree are   -- intended for backwards compatibility with implementations of   -- RFC 1516 [11].  In newer implementations (both single- and   -- multiple-repeater implementations) the rptrInfoTable should   -- be implemented.  It is the preferred source of this information,   -- as it contains the values for all repeaters managed by the   -- agent.  In all cases, the objects in the rptrRptrInfo subtree   -- are duplicates of the corresponding objects in the first entry   -- of the rptrInfoTable.   rptrGroupCapacity OBJECT-TYPE       SYNTAX      Integer32 (1..2147483647)       MAX-ACCESS  read-only       STATUS      deprecated       DESCRIPTION               "********* THIS OBJECT IS DEPRECATED **********               The rptrGroupCapacity is the number of groups               that can be contained within the repeater.  Within               each managed repeater, the groups are uniquely               numbered in the range from 1 to rptrGroupCapacity.               Some groups may not be present in the repeater, in               which case the actual number of groups present               will be less than rptrGroupCapacity.  The number               of groups present will never be greater than               rptrGroupCapacity.               Note:  In practice, this will generally be the               number of field-replaceable units (i.e., modules,               cards, or boards) that can fit in the physical               repeater enclosure, and the group numbers will               correspond to numbers marked on the physical               enclosure."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.1.1.3,               aRepeaterGroupCapacity."       ::= { rptrRptrInfo 1 }   rptrOperStatus OBJECT-TYPE       SYNTAX      INTEGER {                     other(1),            -- undefined or unknown                     ok(2),               -- no known failures                     rptrFailure(3),      -- repeater-related failure                     groupFailure(4),     -- group-related failure                     portFailure(5),      -- port-related failure                     generalFailure(6)    -- failure, unspecified type                   }       MAX-ACCESS  read-only       STATUS      deprecated       DESCRIPTION               "********* THIS OBJECT IS DEPRECATED **********               The rptrOperStatus object indicates the               operational state of the repeater.  The               rptrHealthText object may be consulted for more               specific information about the state of the               repeater's health.               In the case of multiple kinds of failures (e.g.,               repeater failure and port failure), the value of               this attribute shall reflect the highest priority               failure in the following order, listed highest               priority first:                   rptrFailure(3)                   groupFailure(4)                   portFailure(5)                   generalFailure(6)."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.1.1.5, aRepeaterHealthState."       ::= { rptrRptrInfo 2 }   rptrHealthText OBJECT-TYPE       SYNTAX      DisplayString (SIZE (0..255))       MAX-ACCESS  read-only       STATUS      deprecated       DESCRIPTION               "********* THIS OBJECT IS DEPRECATED **********               The health text object is a text string that               provides information relevant to the operational               state of the repeater.  Agents may use this string               to provide detailed information on current               failures, including how they were detected, and/or               instructions for problem resolution.  The contents               are agent-specific."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.1.1.6, aRepeaterHealthText."       ::= { rptrRptrInfo 3 }   rptrReset OBJECT-TYPE       SYNTAX      INTEGER {                     noReset(1),                     reset(2)                   }       MAX-ACCESS  read-write       STATUS      deprecated       DESCRIPTION               "********* THIS OBJECT IS DEPRECATED **********               Setting this object to reset(2) causes a               transition to the START state of Fig 9-2 in               section 9 [IEEE 802.3 Std] for a 10Mb/s repeater,               and the START state of Fig 27-2 in section 27               of that standard for a 100Mb/s repeater.               Setting this object to noReset(1) has no effect.               The agent will always return the value noReset(1)               when this object is read.               After receiving a request to set this variable to               reset(2), the agent is allowed to delay the reset               for a short period.  For example, the implementor               may choose to delay the reset long enough to allow               the SNMP response to be transmitted.  In any               event, the SNMP response must be transmitted.               This action does not reset the management counters               defined in this document nor does it affect the               portAdminStatus parameters.  Included in this               action is the execution of a disruptive Self-Test               with the following characteristics:  a) The nature               of the tests is not specified.  b) The test resets               the repeater but without affecting management               information about the repeater.  c) The test does               not inject packets onto any segment.  d) Packets               received during the test may or may not be               transferred.  e) The test does not interfere with               management functions.               After performing this self-test, the agent will               update the repeater health information (including               rptrOperStatus and rptrHealthText), and send a               rptrHealth trap."       REFERENCE               "[IEEE 802.3 Mgt], 30.4.1.2.1, acResetRepeater."

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -