📄 rfc2495.mib
字号:
DS1-MIB DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, transmission FROM SNMPv2-SMI DisplayString, TimeStamp, TruthValue FROM SNMPv2-TC MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP FROM SNMPv2-CONF InterfaceIndex, ifIndex FROM IF-MIB PerfCurrentCount, PerfIntervalCount, PerfTotalCount FROM PerfHist-TC-MIB; ds1 MODULE-IDENTITY LAST-UPDATED "9808011830Z" ORGANIZATION "IETF Trunk MIB Working Group" CONTACT-INFO " David Fowler Postal: Newbridge Networks Corporation 600 March Road Kanata, Ontario, Canada K2K 2E6 Tel: +1 613 591 3600 Fax: +1 613 599 3667 E-mail: davef@newbridge.com" DESCRIPTION "The MIB module to describe DS1, E1, DS2, and E2 interfaces objects." ::= { transmission 18 } -- note that this subsumes cept (19) and g703at2mb (67) -- there is no separate CEPT or G703AT2MB MIB -- The DS1 Near End Group -- The DS1 Near End Group consists of five tables: -- DS1 Configuration -- DS1 Current -- DS1 Interval -- DS1 Total -- DS1 Channel Table -- The DS1 Configuration Table dsx1ConfigTable OBJECT-TYPE SYNTAX SEQUENCE OF Dsx1ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The DS1 Configuration table." ::= { ds1 6 } dsx1ConfigEntry OBJECT-TYPE SYNTAX Dsx1ConfigEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry in the DS1 Configuration table." INDEX { dsx1LineIndex } ::= { dsx1ConfigTable 1 } Dsx1ConfigEntry ::= SEQUENCE { dsx1LineIndex InterfaceIndex, dsx1IfIndex InterfaceIndex, dsx1TimeElapsed INTEGER, dsx1ValidIntervals INTEGER, dsx1LineType INTEGER, dsx1LineCoding INTEGER, dsx1SendCode INTEGER, dsx1CircuitIdentifier DisplayString, dsx1LoopbackConfig INTEGER, dsx1LineStatus INTEGER, dsx1SignalMode INTEGER, dsx1TransmitClockSource INTEGER, dsx1Fdl INTEGER, dsx1InvalidIntervals INTEGER, dsx1LineLength INTEGER, dsx1LineStatusLastChange TimeStamp, dsx1LineStatusChangeTrapEnable INTEGER, dsx1LoopbackStatus INTEGER, dsx1Ds1ChannelNumber INTEGER, dsx1Channelization INTEGER } dsx1LineIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS current DESCRIPTION "This object should be made equal to ifIndex. The next paragraph describes its previous usage. Making the object equal to ifIndex allows proper use of ifStackTable and ds0/ds0bundle mibs. Previously, this object is the identifier of a DS1 Interface on a managed device. If there is an ifEntry that is directly associated with this and only this DS1 interface, it should have the same value as ifIndex. Otherwise, number the dsx1LineIndices with an unique identifier following the rules of choosing a number that is greater than ifNumber and numbering the inside interfaces (e.g., equipment side) with even numbers and outside interfaces (e.g, network side) with odd numbers." ::= { dsx1ConfigEntry 1 } dsx1IfIndex OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-only STATUS deprecated DESCRIPTION "This value for this object is equal to the value of ifIndex from the Interfaces table of MIB II (RFC 1213)." ::= { dsx1ConfigEntry 2 } dsx1TimeElapsed OBJECT-TYPE SYNTAX INTEGER (0..899) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of seconds that have elapsed since the beginning of the near end current error- measurement period. If, for some reason, such as an adjustment in the system's time-of-day clock, the current interval exceeds the maximum value, the agent will return the maximum value." ::= { dsx1ConfigEntry 3 } dsx1ValidIntervals OBJECT-TYPE SYNTAX INTEGER (0..96) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of previous near end intervals for which data was collected. The value will be 96 unless the interface was brought online within the last 24 hours, in which case the value will be the number of complete 15 minute near end intervals since the interface has been online. In the case where the agent is a proxy, it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available." ::= { dsx1ConfigEntry 4 } dsx1LineType OBJECT-TYPE SYNTAX INTEGER { other(1), dsx1ESF(2), dsx1D4(3), dsx1E1(4), dsx1E1CRC(5), dsx1E1MF(6), dsx1E1CRCMF(7), dsx1Unframed(8), dsx1E1Unframed(9), dsx1DS2M12(10), dsx2E2(11) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates the variety of DS1 Line implementing this circuit. The type of circuit affects the number of bits per second that the circuit can reasonably carry, as well as the interpretation of the usage and error statistics. The values, in sequence, describe: TITLE: SPECIFICATION: dsx1ESF Extended SuperFrame DS1 (T1.107) dsx1D4 AT&T D4 format DS1 (T1.107) dsx1E1 ITU-T Recommendation G.704 (Table 4a) dsx1E1-CRC ITU-T Recommendation G.704 (Table 4b) dsxE1-MF G.704 (Table 4a) with TS16 multiframing enabled dsx1E1-CRC-MF G.704 (Table 4b) with TS16 multiframing enabled dsx1Unframed DS1 with No Framing dsx1E1Unframed E1 with No Framing (G.703) dsx1DS2M12 DS2 frame format (T1.107) dsx1E2 E2 frame format (G.704) For clarification, the capacity for each E1 type is as listed below: dsx1E1Unframed - E1, no framing = 32 x 64k = 2048k dsx1E1 or dsx1E1CRC - E1, with framing, no signalling = 31 x 64k = 1984k dsx1E1MF or dsx1E1CRCMF - E1, with framing, signalling = 30 x 64k = 1920k For further information See ITU-T Recomm G.704" ::= { dsx1ConfigEntry 5 } dsx1LineCoding OBJECT-TYPE SYNTAX INTEGER { dsx1JBZS (1), dsx1B8ZS (2), dsx1HDB3 (3), dsx1ZBTSI (4), dsx1AMI (5), other(6), dsx1B6ZS(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable describes the variety of Zero Code Suppression used on this interface, which in turn affects a number of its characteristics. dsx1JBZS refers the Jammed Bit Zero Suppression, in which the AT&T specification of at least one pulse every 8 bit periods is literally implemented by forcing a pulse in bit 8 of each channel. Thus, only seven bits per channel, or 1.344 Mbps, is available for data. dsx1B8ZS refers to the use of a specified pattern of normal bits and bipolar violations which are used to replace a sequence of eight zero bits. ANSI Clear Channels may use dsx1ZBTSI, or Zero Byte Time Slot Interchange. E1 links, with or without CRC, use dsx1HDB3 or dsx1AMI. dsx1AMI refers to a mode wherein no zero code suppression is present and the line encoding does not solve the problem directly. In this application, the higher layer must provide data which meets or exceeds the pulse density requirements, such as inverting HDLC data. dsx1B6ZS refers to the user of a specifed pattern of normal bits and bipolar violations which are used to replace a sequence of six zero bits. Used for DS2." ::= { dsx1ConfigEntry 6 } dsx1SendCode OBJECT-TYPE SYNTAX INTEGER { dsx1SendNoCode(1), dsx1SendLineCode(2), dsx1SendPayloadCode(3), dsx1SendResetCode(4), dsx1SendQRS(5), dsx1Send511Pattern(6), dsx1Send3in24Pattern(7), dsx1SendOtherTestPattern(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable indicates what type of code is being sent across the DS1 interface by the device. Setting this variable causes the interface to send the code requested. The values mean: dsx1SendNoCode sending looped or normal data dsx1SendLineCode sending a request for a line loopback dsx1SendPayloadCode sending a request for a payload loopback dsx1SendResetCode sending a loopback termination request dsx1SendQRS sending a Quasi-Random Signal (QRS) test pattern dsx1Send511Pattern sending a 511 bit fixed test pattern dsx1Send3in24Pattern sending a fixed test pattern of 3 bits set in 24 dsx1SendOtherTestPattern sending a test pattern other than those described by this object"::= { dsx1ConfigEntry 7 } dsx1CircuitIdentifier OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "This variable contains the transmission vendor's circuit identifier, for the purpose of facilitating troubleshooting." ::= { dsx1ConfigEntry 8 } dsx1LoopbackConfig OBJECT-TYPE SYNTAX INTEGER { dsx1NoLoop(1), dsx1PayloadLoop(2), dsx1LineLoop(3), dsx1OtherLoop(4), dsx1InwardLoop(5), dsx1DualLoop(6) } MAX-ACCESS read-write STATUS current DESCRIPTION "This variable represents the desired loopback configuration of the DS1 interface. Agents supporting read/write access should return inconsistentValue in response to a requested loopback state that the interface does not support. The values mean: dsx1NoLoop Not in the loopback state. A device that is not capable of performing a loopback on the interface shall always return this as its value. dsx1PayloadLoop The received signal at this interface is looped through the device. Typically the received signal is looped back for retransmission after it has passed through the device's framing function. dsx1LineLoop The received signal at this interface does not go through the device (minimum penetration) but is looped back out.
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -