⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc2495.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
📖 第 1 页 / 共 5 页
字号:
     DS1-MIB DEFINITIONS ::= BEGIN     IMPORTS          MODULE-IDENTITY, OBJECT-TYPE,          NOTIFICATION-TYPE, transmission         FROM SNMPv2-SMI          DisplayString, TimeStamp, TruthValue    FROM SNMPv2-TC          MODULE-COMPLIANCE, OBJECT-GROUP,          NOTIFICATION-GROUP                      FROM SNMPv2-CONF          InterfaceIndex, ifIndex                 FROM IF-MIB          PerfCurrentCount, PerfIntervalCount,          PerfTotalCount                          FROM PerfHist-TC-MIB;     ds1 MODULE-IDENTITY         LAST-UPDATED "9808011830Z"         ORGANIZATION "IETF Trunk MIB Working Group"         CONTACT-INFO           "        David Fowler            Postal: Newbridge Networks Corporation                    600 March Road                    Kanata, Ontario, Canada K2K 2E6                    Tel: +1 613 591 3600                    Fax: +1 613 599 3667            E-mail: davef@newbridge.com"         DESCRIPTION              "The MIB module to describe DS1, E1, DS2, and               E2 interfaces objects."         ::= { transmission 18 }     -- note that this subsumes cept (19) and g703at2mb (67)     -- there is no separate CEPT or G703AT2MB MIB     -- The DS1 Near End Group     -- The DS1 Near End Group consists of five tables:     --    DS1 Configuration     --    DS1 Current     --    DS1 Interval     --    DS1 Total     --    DS1 Channel Table     -- The DS1 Configuration Table     dsx1ConfigTable OBJECT-TYPE          SYNTAX  SEQUENCE OF Dsx1ConfigEntry          MAX-ACCESS  not-accessible          STATUS  current          DESCRIPTION                 "The DS1 Configuration table."          ::= { ds1 6 }     dsx1ConfigEntry OBJECT-TYPE          SYNTAX  Dsx1ConfigEntry          MAX-ACCESS  not-accessible          STATUS  current          DESCRIPTION                 "An entry in the DS1 Configuration table."          INDEX   { dsx1LineIndex }          ::= { dsx1ConfigTable 1 }     Dsx1ConfigEntry ::=          SEQUENCE {              dsx1LineIndex                        InterfaceIndex,              dsx1IfIndex                          InterfaceIndex,              dsx1TimeElapsed                      INTEGER,              dsx1ValidIntervals                   INTEGER,              dsx1LineType                         INTEGER,              dsx1LineCoding                       INTEGER,              dsx1SendCode                         INTEGER,              dsx1CircuitIdentifier                DisplayString,              dsx1LoopbackConfig                   INTEGER,              dsx1LineStatus                       INTEGER,              dsx1SignalMode                       INTEGER,              dsx1TransmitClockSource              INTEGER,              dsx1Fdl                              INTEGER,              dsx1InvalidIntervals                 INTEGER,              dsx1LineLength                       INTEGER,              dsx1LineStatusLastChange             TimeStamp,              dsx1LineStatusChangeTrapEnable       INTEGER,              dsx1LoopbackStatus                   INTEGER,              dsx1Ds1ChannelNumber                 INTEGER,              dsx1Channelization                   INTEGER     }     dsx1LineIndex OBJECT-TYPE          SYNTAX  InterfaceIndex          MAX-ACCESS  read-only          STATUS  current          DESCRIPTION                 "This object should be made equal to ifIndex.  The                 next paragraph describes its previous usage.                 Making the object equal to ifIndex allows proper                 use of ifStackTable and ds0/ds0bundle mibs.                 Previously, this object is the identifier of a DS1                 Interface on a managed device.  If there is an                 ifEntry that is directly associated with this and                 only this DS1 interface, it should have the same                 value as ifIndex.  Otherwise, number the                 dsx1LineIndices with an unique identifier                 following the rules of choosing a number that is                 greater than ifNumber and numbering the inside                 interfaces (e.g., equipment side) with even                 numbers and outside interfaces (e.g, network side)                 with odd numbers."          ::= { dsx1ConfigEntry 1 }     dsx1IfIndex OBJECT-TYPE          SYNTAX  InterfaceIndex          MAX-ACCESS  read-only          STATUS  deprecated          DESCRIPTION                 "This value for this object is equal to the value                 of ifIndex from the Interfaces table of MIB II                 (RFC 1213)."          ::= { dsx1ConfigEntry 2 }     dsx1TimeElapsed OBJECT-TYPE          SYNTAX  INTEGER (0..899)          MAX-ACCESS  read-only          STATUS  current          DESCRIPTION                   "The number of seconds that have elapsed since                        the beginning of the near end current error-                   measurement period.  If, for some reason, such                        as an adjustment in the system's time-of-day                        clock, the current interval exceeds the maximum                        value, the agent will return the maximum value."          ::= { dsx1ConfigEntry 3 }     dsx1ValidIntervals OBJECT-TYPE          SYNTAX  INTEGER (0..96)          MAX-ACCESS  read-only          STATUS  current          DESCRIPTION                 "The number of previous near end intervals for                 which data was collected.  The value will be                 96 unless the interface was brought online within                 the last 24 hours, in which case the value will be                 the number of complete 15 minute near end                 intervals since the interface has been online.  In                 the case where the agent is a proxy, it is                 possible that some intervals are unavailable.  In                 this case, this interval is the maximum interval                 number for which data is available."          ::= { dsx1ConfigEntry 4 }     dsx1LineType OBJECT-TYPE          SYNTAX  INTEGER {                     other(1),                     dsx1ESF(2),                     dsx1D4(3),                     dsx1E1(4),                     dsx1E1CRC(5),                     dsx1E1MF(6),                     dsx1E1CRCMF(7),                     dsx1Unframed(8),                     dsx1E1Unframed(9),                     dsx1DS2M12(10),                     dsx2E2(11)                 }          MAX-ACCESS  read-write          STATUS  current          DESCRIPTION                 "This variable indicates  the  variety  of  DS1                 Line  implementing  this  circuit.  The type of                 circuit affects the number of bits  per  second                 that  the circuit can reasonably carry, as well                 as the interpretation of the  usage  and  error                 statistics.  The values, in sequence, describe:                 TITLE:         SPECIFICATION:                 dsx1ESF         Extended SuperFrame DS1 (T1.107)                 dsx1D4          AT&T D4 format DS1 (T1.107)                 dsx1E1          ITU-T Recommendation G.704                                  (Table 4a)                 dsx1E1-CRC      ITU-T Recommendation G.704                                  (Table 4b)                 dsxE1-MF        G.704 (Table 4a) with TS16                                  multiframing enabled                 dsx1E1-CRC-MF   G.704 (Table 4b) with TS16                                  multiframing enabled                 dsx1Unframed    DS1 with No Framing                 dsx1E1Unframed  E1 with No Framing (G.703)                 dsx1DS2M12      DS2 frame format (T1.107)                 dsx1E2          E2 frame format (G.704)                 For clarification, the capacity for each E1 type                 is as listed below:                 dsx1E1Unframed - E1, no framing = 32 x 64k = 2048k                 dsx1E1 or dsx1E1CRC - E1, with framing,                    no signalling = 31 x 64k = 1984k                 dsx1E1MF or dsx1E1CRCMF - E1, with framing,                    signalling = 30 x 64k = 1920k                 For further information See ITU-T Recomm G.704"          ::= { dsx1ConfigEntry 5 }     dsx1LineCoding OBJECT-TYPE          SYNTAX  INTEGER {                     dsx1JBZS (1),                     dsx1B8ZS (2),                     dsx1HDB3 (3),                     dsx1ZBTSI (4),                     dsx1AMI (5),                     other(6),                     dsx1B6ZS(7)                 }          MAX-ACCESS  read-write          STATUS  current          DESCRIPTION                 "This variable describes the variety of Zero Code                 Suppression used on this interface, which in turn                 affects a number of its characteristics.                 dsx1JBZS refers the Jammed Bit Zero Suppression,                 in which the AT&T specification of at least one                 pulse every 8 bit periods is literally implemented                 by forcing a pulse in bit 8 of each channel.                 Thus, only seven bits per channel, or 1.344 Mbps,                 is available for data.                 dsx1B8ZS refers to the use of a specified pattern                 of normal bits and bipolar violations which are                 used to replace a sequence of eight zero bits.                 ANSI Clear Channels may use dsx1ZBTSI, or Zero                 Byte Time Slot Interchange.                 E1 links, with or without CRC, use dsx1HDB3 or                 dsx1AMI.                 dsx1AMI refers to a mode wherein no zero code                 suppression is present and the line encoding does                 not solve the problem directly.  In this                 application, the higher layer must provide data                 which meets or exceeds the pulse density                 requirements, such as inverting HDLC data.                 dsx1B6ZS refers to the user of a specifed pattern                 of normal bits and bipolar violations which are                 used to replace a sequence of six zero bits.  Used                 for DS2."          ::= { dsx1ConfigEntry 6 }     dsx1SendCode OBJECT-TYPE          SYNTAX  INTEGER {                    dsx1SendNoCode(1),                    dsx1SendLineCode(2),                    dsx1SendPayloadCode(3),                    dsx1SendResetCode(4),                    dsx1SendQRS(5),                    dsx1Send511Pattern(6),                    dsx1Send3in24Pattern(7),                    dsx1SendOtherTestPattern(8)                    }          MAX-ACCESS  read-write          STATUS  current          DESCRIPTION                 "This variable indicates what type of code is                 being sent across the DS1 interface by the device.                 Setting this variable causes the interface to send                 the code requested.  The values mean:           dsx1SendNoCode                sending looped or normal data           dsx1SendLineCode                sending a request for a line loopback           dsx1SendPayloadCode                sending a request for a payload loopback           dsx1SendResetCode                sending a loopback termination request           dsx1SendQRS                sending a Quasi-Random Signal  (QRS)  test                pattern           dsx1Send511Pattern                sending a 511 bit fixed test pattern           dsx1Send3in24Pattern                sending a fixed test pattern of 3 bits set                in 24           dsx1SendOtherTestPattern                sending a test pattern  other  than  those                described by this object"::= { dsx1ConfigEntry 7 }     dsx1CircuitIdentifier OBJECT-TYPE          SYNTAX  DisplayString (SIZE (0..255))          MAX-ACCESS  read-write          STATUS  current          DESCRIPTION                 "This variable contains the transmission vendor's                 circuit identifier, for the purpose of                 facilitating troubleshooting."          ::= { dsx1ConfigEntry 8 }     dsx1LoopbackConfig OBJECT-TYPE          SYNTAX  INTEGER {                      dsx1NoLoop(1),                      dsx1PayloadLoop(2),                      dsx1LineLoop(3),                      dsx1OtherLoop(4),                      dsx1InwardLoop(5),                      dsx1DualLoop(6)                    }          MAX-ACCESS  read-write          STATUS  current          DESCRIPTION                 "This variable represents the desired loopback                 configuration of the DS1 interface.  Agents                 supporting read/write access should return                 inconsistentValue in response to a requested                 loopback state that the interface does not                 support.  The values mean:                 dsx1NoLoop                  Not in the loopback state.  A device that is not                 capable of performing a loopback on the interface                 shall always return this as its value.                 dsx1PayloadLoop                  The received signal at this interface is looped                 through the device.  Typically the received signal                 is looped back for retransmission after it has                 passed through the device's framing function.                 dsx1LineLoop                  The received signal at this interface does not go                 through the device (minimum penetration) but is                 looped back out.

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -