⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 rfc3176.mib

📁 wm PNE 3.3 source code, running at more than vxworks6.x version.
💻 MIB
字号:
SFLOW-MIB DEFINITIONS ::= BEGINIMPORTSMODULE-IDENTITY, OBJECT-TYPE, Integer32, enterprises        FROM SNMPv2-SMISnmpAdminString        FROM SNMP-FRAMEWORK-MIBOwnerString        FROM RMON-MIBInetAddressType, InetAddress        FROM INET-ADDRESS-MIBMODULE-COMPLIANCE, OBJECT-GROUP        FROM SNMPv2-CONF;sFlowMIB  MODULE-IDENTITY  LAST-UPDATED "200105150000Z"   -- May 15, 2001  ORGANIZATION "InMon Corp."  CONTACT-INFO         "Peter Phaal          InMon Corp.          http://www.inmon.com/          Tel:  +1-415-661-6343          Email: peter_phaal@inmon.com"  DESCRIPTION          "The MIB module for managing the generation and transportation           of sFlow data records."  --  -- Revision History  --  REVISION    "200105150000Z"     -- May 15, 2001  DESCRIPTION          "Version 1.2           Brings MIB into SMI v2 compliance."  REVISION    "200105010000Z"      -- May 1, 2001  DESCRIPTION           "Version 1.1            Adds sFlowDatagramVersion."  ::= { enterprises 4300 1 }sFlowAgent OBJECT IDENTIFIER ::= { sFlowMIB 1 }sFlowVersion OBJECT-TYPE     SYNTAX      SnmpAdminString     MAX-ACCESS  read-only     STATUS      current     DESCRIPTION       "Uniquely identifies the version and implementation of this MIB.        The version string must have the following structure:           <MIB Version>;<Organization>;<Software Revision>        where:           <MIB Version>  must be '1.2', the version of this MIB.           <Organization> the name of the organization responsible                            for the agent implementation.           <Revision>     the specific software build of this agent.        As an example, the string '1.2;InMon Corp.;2.1.1' indicates        that this agent implements version '1.2' of the SFLOW MIB, that        it was developed by 'InMon Corp.' and that the software build        is '2.1.1'.        The MIB Version will change with each revision of the SFLOW        MIB.        Management entities must check the MIB Version and not attempt        to manage agents with MIB Versions greater than that for which        they were designed.        Note: The sFlow Datagram Format has an independent version              number which may change independently from <MIB Version>.              <MIB Version> applies to the structure and semantics of              the SFLOW MIB only."     DEFVAL { "1.2;;" }     ::= { sFlowAgent 1 }sFlowAgentAddressType OBJECT-TYPE     SYNTAX      InetAddressType     MAX-ACCESS  read-only     STATUS      current     DESCRIPTION       "The address type of the address associated with this agent.        Only ipv4 and ipv6 types are supported."     ::= { sFlowAgent 2 }sFlowAgentAddress OBJECT-TYPE     SYNTAX      InetAddress     MAX-ACCESS  read-only     STATUS      current     DESCRIPTION       "The IP address associated with this agent.  In the case of a        multi-homed agent, this should be the loopback address of the        agent.  The sFlowAgent address must provide SNMP connectivity        to the agent.  The address should be an invariant that does not        change as interfaces are reconfigured, enabled, disabled,        added or removed.  A manager should be able to use the        sFlowAgentAddress as a unique key that will identify this        agent over extended periods of time so that a history can        be maintained."    ::= { sFlowAgent 3 }sFlowTable OBJECT-TYPE     SYNTAX      SEQUENCE OF SFlowEntry     MAX-ACCESS  not-accessible     STATUS      current     DESCRIPTION       "A table of the sFlow samplers within a device."     ::= { sFlowAgent 4 }sFlowEntry OBJECT-TYPE     SYNTAX      SFlowEntry     MAX-ACCESS  not-accessible     STATUS      current     DESCRIPTION       "Attributes of an sFlow sampler."     INDEX { sFlowDataSource }     ::= { sFlowTable 1 }SFlowEntry ::= SEQUENCE {     sFlowDataSource               OBJECT IDENTIFIER,     sFlowOwner                    OwnerString,     sFlowTimeout                  Integer32,     sFlowPacketSamplingRate       Integer32,     sFlowCounterSamplingInterval  Integer32,     sFlowMaximumHeaderSize        Integer32,     sFlowMaximumDatagramSize      Integer32,     sFlowCollectorAddressType     InetAddressType,     sFlowCollectorAddress         InetAddress,     sFlowCollectorPort            Integer32,     sFlowDatagramVersion          Integer32}sFlowDataSource OBJECT-TYPE     SYNTAX      OBJECT IDENTIFIER     MAX-ACCESS  read-only     STATUS      current     DESCRIPTION       "Identifies the source of the data for the sFlow sampler.       The following data source types are currently defined:       - ifIndex.<I>       DataSources of this traditional form are called 'port-based'.       Ideally the sampling entity will perform sampling on all flows       originating from or destined to the specified interface.       However, if the switch architecture only permits input or       output sampling then the sampling agent is permitted to only       sample input flows input or output flows.  Each packet must       only be considered once for sampling, irrespective of the       number of ports it will be forwarded to.       Note: Port 0 is used to indicate that all ports on the device             are represented by a single data source.             - sFlowPacketSamplingRate applies to all ports on the               device capable of packet sampling.             - sFlowCounterSamplingInterval applies to all ports.       - smonVlanDataSource.<V>       A dataSource of this form refers to a 'Packet-based VLAN'       and is called a 'VLAN-based' dataSource.  <V> is the VLAN       ID as defined by the IEEE 802.1Q standard.  The       value is between 1 and 4094 inclusive, and it represents       an 802.1Q VLAN-ID with global scope within a given       bridged domain.       Sampling is performed on all packets received that are part       of the specified VLAN (no matter which port they arrived on).       Each packet will only be considered once for sampling,       irrespective of the number of ports it will be forwarded to.       - entPhysicalEntry.<N>       A dataSource of this form refers to a physical entity within       the agent (e.g., entPhysicalClass = backplane(4)) and is called       an 'entity-based' dataSource.       Sampling is performed on all packets entering the resource (e.g.       If the backplane is being sampled, all packets transmitted onto       the backplane will be considered as single candidates for       sampling irrespective of the number of ports they ultimately       reach).       Note: Since each DataSource operates independently, a packet             that crosses multiple DataSources may generate multiple             flow records."     ::= { sFlowEntry 1 }sFlowOwner OBJECT-TYPE     SYNTAX      OwnerString     MAX-ACCESS  read-write     STATUS      current     DESCRIPTION       "The entity making use of this sFlow sampler.  The empty string        indicates that the sFlow sampler is currently unclaimed.        An entity wishing to claim an sFlow sampler must make sure        that the sampler is unclaimed before trying to claim it.        The sampler is claimed by setting the owner string to identify        the entity claiming the sampler.  The sampler must be claimed        before any changes can be made to other sampler objects.        In order to avoid a race condition, the entity taking control        of the sampler must set both the owner and a value for        sFlowTimeout in the same SNMP set request.        When a management entity is finished using the sampler,        it should set its value back to unclaimed.  The agent        must restore all other entities this row to their        default values when the owner is set to unclaimed.        This mechanism provides no enforcement and relies on the        cooperation of management entities in order to ensure that        competition for a sampler is fairly resolved."     DEFVAL { "" }     ::= { sFlowEntry 2 }sFlowTimeout OBJECT-TYPE     SYNTAX      Integer32     MAX-ACCESS  read-write     STATUS      current     DESCRIPTION       "The time (in seconds) remaining before the sampler is released        and stops sampling.  When set, the owner establishes control        for the specified period.  When read, the remaining time in the        interval is returned.        A management entity wanting to maintain control of the sampler        is responsible for setting a new value before the old one        expires.        When the interval expires, the agent is responsible for        restoring all other entities in this row to their default        values."     DEFVAL { 0 }     ::= { sFlowEntry 3 }sFlowPacketSamplingRate OBJECT-TYPE     SYNTAX      Integer32     MAX-ACCESS  read-write     STATUS      current     DESCRIPTION       "The statistical sampling rate for packet sampling from this        source.        Set to N to sample 1/Nth of the packets in the monitored flows.        An agent should choose its own algorithm introduce variance        into the sampling so that exactly every Nth packet is not        counted.  A sampling rate of 1 counts all packets.  A sampling        rate of 0 disables sampling.        The agent is permitted to have minimum and maximum allowable        values for the sampling rate.  A minimum rate lets the agent        designer set an upper bound on the overhead associated with        sampling, and a maximum rate may be the result of hardware        restrictions (such as counter size).  In addition not all values        between the maximum and minimum may be realizable as the        sampling rate (again because of implementation considerations).        When the sampling rate is set the agent is free to adjust the        value so that it lies between the maximum and minimum values        and has the closest achievable value.        When read, the agent must return the actual sampling rate it        will be using (after the adjustments previously described).  The        sampling algorithm must converge so that over time the number        of packets sampled approaches 1/Nth of the total number of        packets in the monitored flows."     DEFVAL { 0 }     ::= { sFlowEntry 4 }sFlowCounterSamplingInterval OBJECT-TYPE  SYNTAX      Integer32     MAX-ACCESS  read-write     STATUS      current     DESCRIPTION       "The maximum number of seconds between successive samples of the        counters associated with this data source.  A sampling interval        of 0 disables counter sampling."     DEFVAL { 0 }     ::= { sFlowEntry 5 }sFlowMaximumHeaderSize OBJECT-TYPE     SYNTAX      Integer32     MAX-ACCESS  read-write     STATUS      current     DESCRIPTION       "The maximum number of bytes that should be copied from a        sampled packet.  The agent may have an internal maximum and        minimum permissible sizes.  If an attempt is made to set this        value outside the permissible range then the agent should        adjust the value to the closest permissible value."     DEFVAL { 128 }     ::= { sFlowEntry 6 }sFlowMaximumDatagramSize OBJECT-TYPE     SYNTAX      Integer32     MAX-ACCESS  read-write     STATUS      current     DESCRIPTION        "The maximum number of data bytes that can be sent in a single         sample datagram.  The manager should set this value to avoid         fragmentation of the sFlow datagrams."     DEFVAL { 1400 }     ::= { sFlowEntry 7 }sFlowCollectorAddressType OBJECT-TYPE     SYNTAX      InetAddressType     MAX-ACCESS  read-write     STATUS      current     DESCRIPTION       "The type of sFlowCollectorAddress."     DEFVAL { ipv4 }     ::= { sFlowEntry 8 }sFlowCollectorAddress OBJECT-TYPE     SYNTAX      InetAddress     MAX-ACCESS  read-write     STATUS      current     DESCRIPTION       "The IP address of the sFlow collector.        If set to 0.0.0.0 all sampling is disabled."     DEFVAL { "0.0.0.0" }     ::= { sFlowEntry 9 }sFlowCollectorPort OBJECT-TYPE     SYNTAX      Integer32     MAX-ACCESS  read-write     STATUS      current     DESCRIPTION       "The destination port for sFlow datagrams."     DEFVAL { 6343 }     ::= { sFlowEntry 10 }sFlowDatagramVersion OBJECT-TYPE     SYNTAX      Integer32     MAX-ACCESS  read-write     STATUS      current     DESCRIPTION       "The version of sFlow datagrams that should be sent.        When set to a value not support by the agent, the agent should        adjust the value to the highest supported value less than the        requested value, or return an error if no such values exist."     DEFVAL { 4 }     ::= { sFlowEntry 11 } -- -- Compliance Statements --sFlowMIBConformance OBJECT IDENTIFIER ::= { sFlowMIB 2 }sFlowMIBGroups      OBJECT IDENTIFIER ::= { sFlowMIBConformance 1 }sFlowMIBCompliances OBJECT IDENTIFIER ::= { sFlowMIBConformance 2 }sFlowCompliance MODULE-COMPLIANCE     STATUS      current     DESCRIPTION       "Compliance statements for the sFlow Agent."     MODULE -- this module         MANDATORY-GROUPS { sFlowAgentGroup }         OBJECT     sFlowAgentAddressType--         SYNTAX     InetAddressType { ipv4(1) }         SYNTAX     INTEGER { ipv4(1) }         DESCRIPTION           "Agents need only support ipv4."         OBJECT sFlowCollectorAddressType--         SYNTAX     InetAddressType { ipv4(1) }         SYNTAX     INTEGER { ipv4(1) }         DESCRIPTION           "Agents need only support ipv4."     ::= { sFlowMIBCompliances 1 }sFlowAgentGroup OBJECT-GROUP     OBJECTS { sFlowVersion, sFlowAgentAddressType, sFlowAgentAddress,               sFlowDataSource, sFlowOwner, sFlowTimeout,               sFlowPacketSamplingRate, sFlowCounterSamplingInterval,               sFlowMaximumHeaderSize, sFlowMaximumDatagramSize,               sFlowCollectorAddressType, sFlowCollectorAddress,               sFlowCollectorPort, sFlowDatagramVersion }      STATUS current      DESCRIPTION        "A collection of objects for managing the generation and         transportation of sFlow data records."       ::= { sFlowMIBGroups 1 }END

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -