📄 rfc1566.mib
字号:
mtaGroupReceivedVolume OBJECT-TYPE SYNTAX Counter32 UNITS "K-octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The total volume of messages received to this group since MTA initialization, measured in kilo-octets. This volume should include all transferred data that is logically above the mail transport protocol level. For example, an SMTP-based MTA should use the number of kilo-octets in the message header and body, while an X.400-based MTA should use the number of kilo-octets of P2 data." ::= {mtaGroupEntry 6} mtaGroupStoredVolume OBJECT-TYPE SYNTAX Gauge32 UNITS "K-octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The total volume of messages currently stored in this group's queue, measured in kilo-octets. This volume should include all stored data that is logically above the mail transport protocol level. For example, an SMTP-based MTA should use the number of kilo-octets in the message header and body, while an X.400-based MTA would use the number of kilo-octets of P2 data." ::= {mtaGroupEntry 7} mtaGroupTransmittedVolume OBJECT-TYPE SYNTAX Counter32 UNITS "K-octets" MAX-ACCESS read-only STATUS current DESCRIPTION "The total volume of messages transmitted by this group since MTA initialization, measured in kilo-octets. This volume should include all transferred data that is logically above the mail transport protocol level. For example, an SMTP-based MTA should use the number of kilo-octets in the message header and body, while an X.400-based MTA should use the number of kilo-octets of P2 data." ::= {mtaGroupEntry 8} mtaGroupReceivedRecipients OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of recipients specified in all messages received to this group since MTA initialization. Recipients this MTA had no responsibility for should not be counted." ::= {mtaGroupEntry 9} mtaGroupStoredRecipients OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of recipients specified in all messages currently stored in this group's queue. Recipients this MTA had no responsibility for should not be counted." ::= {mtaGroupEntry 10} mtaGroupTransmittedRecipients OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of recipients specified in all messages transmitted by this group since MTA initialization. Recipients this MTA had no responsibility for should not be counted." ::= {mtaGroupEntry 11} mtaGroupOldestMessageStored OBJECT-TYPE SYNTAX TimeInterval MAX-ACCESS read-only STATUS current DESCRIPTION "Time since the oldest message in this group's queue was placed in the queue." ::= {mtaGroupEntry 12} mtaGroupInboundAssociations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of current associations to the group, where the group is the responder." ::= {mtaGroupEntry 13} mtaGroupOutboundAssociations OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "The number of current associations to the group, where the group is the initiator." ::= {mtaGroupEntry 14} mtaGroupAccumulatedInboundAssociations OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of associations to the group since MTA initialization, where the group is the responder." ::= {mtaGroupEntry 15} mtaGroupAccumulatedOutboundAssociations OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of associations from the group since MTA initialization, where the group was the initiator." ::= {mtaGroupEntry 16} mtaGroupLastInboundActivity OBJECT-TYPE SYNTAX TimeInterval MAX-ACCESS read-only STATUS current DESCRIPTION "Time since the last time that this group had an active inbound association for purposes of message reception." ::= {mtaGroupEntry 17} mtaGroupLastOutboundActivity OBJECT-TYPE SYNTAX TimeInterval MAX-ACCESS read-only STATUS current DESCRIPTION "Time since the last time that this group had an outbound association for purposes of message delivery." ::= {mtaGroupEntry 18} mtaGroupRejectedInboundAssociations OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of inbound associations the group has rejected, since MTA initialization." ::= {mtaGroupEntry 19} mtaGroupFailedOutboundAssociations OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total number associations where the group was the initiator and association establishment has failed, since MTA initialization." ::= {mtaGroupEntry 20} mtaGroupInboundRejectionReason OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The failure reason, if any, for the last association this group refused to respond to. An empty string indicates that the last attempt was successful. If no association attempt has been made since the MTA was initializaed the value should be 'never'." ::= {mtaGroupEntry 21} mtaGroupOutboundConnectFailureReason OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "The failure reason, if any, for the last association attempt this group initiated. An empty string indicates that the last attempt was successful. If no association attempt has been made since the MTA was initialized the value should be 'never'." ::= {mtaGroupEntry 22} mtaGroupScheduledRetry OBJECT-TYPE SYNTAX TimeInterval MAX-ACCESS read-only STATUS current DESCRIPTION "The time when this group is scheduled to next attempt to make an association." ::= {mtaGroupEntry 23} mtaGroupMailProtocol OBJECT-TYPE SYNTAX OBJECT IDENTIFIER MAX-ACCESS read-only STATUS current DESCRIPTION "An identification of the protocol being used by this group. For an group employing OSI protocols, this will be the Application Context. For Internet applications, the IANA maintains a registry of the OIDs which correspond to well-known message transfer protocols. If the application protocol is not listed in the registry, an OID value of the form {applTCPProtoID port} or {applUDProtoID port} are used for TCP-based and UDP-based protocols, respectively. In either case 'port' corresponds to the primary port number being used by the group. applTCPProtoID and applUDPProtoID are defined in [5]." ::= {mtaGroupEntry 24} mtaGroupName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "A descriptive name for the group. If this group connects to a single remote MTA this should be the name of that MTA. If this in turn is an Internet MTA this should be the domain name. For an OSI MTA it should be the string encoded distinguished name of the managed object using the format defined in RFC-1485. For X.400(1984) MTAs which do not have a Distinguished Name, the RFC-1327 syntax 'mta in globalid' should be used." ::= {mtaGroupEntry 25} mtaGroupAssociationTable OBJECT-TYPE SYNTAX SEQUENCE OF MtaGroupAssociationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table holding information regarding the associations for each MTA group." ::= {mta 3} mtaGroupAssociationEntry OBJECT-TYPE SYNTAX MtaGroupAssociationEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The entry holding information regarding the associations for each MTA group." INDEX {applIndex, mtaGroupIndex, mtaGroupAssociationIndex} ::= {mtaGroupAssociationTable 1} MtaGroupAssociationEntry ::= SEQUENCE { mtaGroupAssociationIndex INTEGER } mtaGroupAssociationIndex OBJECT-TYPE SYNTAX INTEGER (1..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Reference into association table to allow correlation of this group's active associations with the association table." ::= {mtaGroupAssociationEntry 1} -- Conformance information mtaConformance OBJECT IDENTIFIER ::= {mta 4} mtaGroups OBJECT IDENTIFIER ::= {mtaConformance 1} mtaCompliances OBJECT IDENTIFIER ::= {mtaConformance 2} -- Compliance statements mtaCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities which implement the Mail Monitoring MIB for basic monitoring of MTAs." MODULE -- this module MANDATORY-GROUPS {mtaGroup} ::= {mtaCompliances 1} mtaAssocCompliance MODULE-COMPLIANCE STATUS current DESCRIPTION "The compliance statement for SNMPv2 entities which implement the Mail Monitoring MIB for monitoring of MTAs and their associations." MODULE -- this module MANDATORY-GROUPS {mtaGroup, mtaAssocGroup} ::= {mtaCompliances 2} -- Units of conformance mtaGroup OBJECT-GROUP OBJECTS { mtaReceivedMessages, mtaStoredMessages, mtaTransmittedMessages, mtaReceivedVolume, mtaStoredVolume, mtaTransmittedVolume, mtaReceivedRecipients, mtaStoredRecipients, mtaTransmittedRecipients, mtaGroupReceivedMessages, mtaGroupRejectedMessages, mtaGroupStoredMessages, mtaGroupTransmittedMessages, mtaGroupReceivedVolume, mtaGroupStoredVolume, mtaGroupTransmittedVolume, mtaGroupReceivedRecipients, mtaGroupStoredRecipients, mtaGroupTransmittedRecipients, mtaGroupOldestMessageStored, mtaGroupInboundAssociations, mtaGroupOutboundAssociations, mtaGroupAccumulatedInboundAssociations, mtaGroupAccumulatedOutboundAssociations, mtaGroupLastInboundActivity, mtaGroupLastOutboundActivity, mtaGroupRejectedInboundAssociations, mtaGroupFailedOutboundAssociations, mtaGroupInboundRejectionReason, mtaGroupOutboundConnectFailureReason, mtaGroupScheduledRetry, mtaGroupMailProtocol, mtaGroupName} STATUS current DESCRIPTION "A collection of objects providing basic monitoring of MTAs." ::= {mtaGroups 1} mtaAssocGroup OBJECT-GROUP OBJECTS { mtaGroupAssociationIndex} STATUS current DESCRIPTION "A collection of objects providing monitoring of MTA associations." ::= {mtaGroups 2} END
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -