📄 disman-script-mib.txt
字号:
specific. However, the mapping needs to ensure that scripts created by different owners with the same script name do not map to the same name in non-volatile storage." ::= { smScriptEntry 2 }smScriptDescr OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-create STATUS current DESCRIPTION "A description of the purpose of the script." ::= { smScriptEntry 3 }smScriptLanguage OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object type identifies an entry in the smLangTable which is used to execute this script. The special value 0 may be used by hard-wired scripts that can not be modified and that are executed by internal functions. Set requests to change this object are invalid if the value of smScriptOperStatus is `enabled' or `compiling' and will result in an inconsistentValue error. Note that the data type and the range of this object must be consistent with the definition of smLangIndex." ::= { smScriptEntry 4 }smScriptSource OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-create STATUS current DESCRIPTION "This object either contains a reference to the script source or an empty string. A reference must be given in the form of a Uniform Resource Locator (URL) as defined in RFC 2396. The allowed character sets and the encoding rules defined in RFC 2396 section 2 apply. When the smScriptAdminStatus object is set to `enabled', the Script MIB implementation will `pull' the script source from the URL contained in this object if the URL is not empty. An empty URL indicates that the script source is loaded from local storage. The script is read from the smCodeTable if the value of smScriptStorageType is volatile. Otherwise, the script is read from non-volatile storage. Note: This document does not mandate implementation of any specific URL scheme. An attempt to load a script from a nonsupported URL scheme will cause the smScriptOperStatus to report an `unknownProtocol' error. Set requests to change this object are invalid if the value of smScriptOperStatus is `enabled', `editing', `retrieving' or `compiling' and will result in an inconsistentValue error." DEFVAL { ''H } ::= { smScriptEntry 5 }smScriptAdminStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), editing(3) } MAX-ACCESS read-create STATUS current DESCRIPTION "The value of this object indicates the desired status of the script. See the definition of smScriptOperStatus for a description of the values. When the smScriptAdminStatus object is set to `enabled' and the smScriptOperStatus is `disabled' or one of the error states, the Script MIB implementation will `pull' the script source from the URL contained in the smScriptSource object if the URL is not empty." DEFVAL { disabled } ::= { smScriptEntry 6 }smScriptOperStatus OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2), editing(3), retrieving(4), compiling(5), noSuchScript(6), accessDenied(7), wrongLanguage(8), wrongVersion(9), compilationFailed(10), noResourcesLeft(11), unknownProtocol(12), protocolFailure(13), genericError(14) } MAX-ACCESS read-only STATUS current DESCRIPTION "The actual status of the script in the runtime system. The value of this object is only meaningful when the value of the smScriptRowStatus object is `active'. The smScriptOperStatus object may have the following values: - `enabled' indicates that the script is available and can be started by a launch table entry. - `disabled' indicates that the script can not be used. - `editing' indicates that the script can be modified in the smCodeTable. - `retrieving' indicates that the script is currently being loaded from non-volatile storage or a remote system. - `compiling' indicates that the script is currently being compiled by the runtime system. - `noSuchScript' indicates that the script does not exist at the smScriptSource. - `accessDenied' indicates that the script can not be loaded from the smScriptSource due to a lack of permissions. - `wrongLanguage' indicates that the script can not be loaded from the smScriptSource because of a language mismatch. - `wrongVersion' indicates that the script can not be loaded from the smScriptSource because of a language version mismatch. - `compilationFailed' indicates that the compilation failed. - `noResourcesLeft' indicates that the runtime system does not have enough resources to load the script. - `unknownProtocol' indicates that the script could not be loaded from the smScriptSource because the requested protocol is not supported. - `protocolFailure' indicates that the script could not be loaded from the smScriptSource because of a protocol failure. - `genericError' indicates that the script could not be loaded due to an error condition not listed above. The `retrieving' and `compiling' states are transient states which will either lead to one of the error states or the `enabled' state. The `disabled' and `editing' states are administrative states which are only reached by explicit management operations. All launch table entries that refer to this script table entry shall have an smLaunchOperStatus value of `disabled' when the value of this object is not `enabled'." DEFVAL { disabled } ::= { smScriptEntry 7 }smScriptStorageType OBJECT-TYPE SYNTAX StorageType MAX-ACCESS read-create STATUS current DESCRIPTION "This object defines whether this row and the script controlled by this row are kept in volatile storage and lost upon reboot or if this row is backed up by non-volatile or permanent storage. The storage type of this row always complies with the value of this entry if the value of the corresponding RowStatus object is `active'. However, the storage type of the script controlled by this row may be different, if the value of this entry is `non-volatile'. The script controlled by this row is written into local non-volatile storage if the following condition becomes true: (a) the URL contained in the smScriptSource object is empty and (b) the smScriptStorageType is `nonVolatile' and (c) the smScriptOperStatus is `enabled' Setting this object to `volatile' removes a script from non-volatile storage if the script controlled by this row has been in non-volatile storage before. Attempts to set this object to permanent will always fail with an inconsistentValue error. The value of smScriptStorageType is only meaningful if the value of the corresponding RowStatus object is `active'. If smScriptStorageType has the value permanent(4), then all objects whose MAX-ACCESS value is read-create must be writable, with the exception of the smScriptStorageType and smScriptRowStatus objects, which shall be read-only." DEFVAL { volatile } ::= { smScriptEntry 8 }smScriptRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "A control that allows entries to be added and removed from this table. Changing the smScriptRowStatus from `active' to `notInService' will remove the associated script from the runtime system. Deleting conceptual rows from this table may affect the deletion of other resources associated with this row. For example, a script stored in non-volatile storage may be removed from non-volatile storage. An entry may not exist in the `active' state unless all required objects in the entry have appropriate values. Rows that are not complete or not in service are not known by the script runtime system. Attempts to `destroy' a row or to set a row `notInService' while the smScriptOperStatus is `enabled' will result in an inconsistentValue error. Attempts to `destroy' a row or to set a row `notInService' where the value of the smScriptStorageType object is `permanent' or `readOnly' will result in an inconsistentValue error. The value of this object has no effect on whether other objects in this conceptual row can be modified." ::= { smScriptEntry 9 }smScriptError OBJECT-TYPE SYNTAX SnmpAdminString MAX-ACCESS read-only STATUS current DESCRIPTION "This object contains a descriptive error message if the transition into the operational status `enabled' failed. Implementations must reset the error message to a zero-length string when a new attempt to change the script status to `enabled' is started." DEFVAL { ''H } ::= { smScriptEntry 10 }smScriptLastChange OBJECT-TYPE SYNTAX DateAndTime MAX-ACCESS read-only STATUS current DESCRIPTION "The date and time when this script table entry was last modified. The value '0000000000000000'H is returned if the script table entry has not yet been modified. Note that the resetting of smScriptError is not considered a change of the script table entry." DEFVAL { '0000000000000000'H } ::= { smScriptEntry 11 }---- Access to script code via SNMP---- The smCodeTable allows script code to be read and modified-- via SNMP.--smCodeTable OBJECT-TYPE SYNTAX SEQUENCE OF SmCodeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains the script code for scripts that are written via SNMP write operations." ::= { smScriptObjects 2 }smCodeEntry OBJECT-TYPE SYNTAX SmCodeEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An entry describing a particular fragment of a script." INDEX { smScriptOwner, smScriptName, smCodeIndex } ::= { smCodeTable 1 }SmCodeEntry ::= SEQUENCE { smCodeIndex Unsigned32, smCodeText OCTET STRING, smCodeRowStatus RowStatus}smCodeIndex OBJECT-TYPE SYNTAX Unsigned32 (1..4294967295) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The index value identifying this code fragment." ::= { smCodeEntry 1 }smCodeText OBJECT-TYPE SYNTAX OCTET STRING (SIZE (1..1024)) MAX-ACCESS read-create STATUS current DESCRIPTION "The code that makes up a fragment of a script. The format of this code fragment depends on the script language which is identified by the associated smScriptLanguage object." ::= { smCodeEntry 2 }smCodeRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "A control that allows entries to be added and removed from this table. The value of this object has no effect on whether other objects in this conceptual row can be modified." ::= { smCodeEntry 3 }---- Script execution.---- This group defines tables which allow script execution to be-- initiated, suspended, resumed, and terminated. It also provides-- a mechanism for keeping a history of recent script executions-- and their results.--smRunObjects OBJECT IDENTIFIER ::= { smObjects 4 }smLaunchTable OBJECT-TYPE SYNTAX SEQUENCE OF SmLaunchEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table lists and describes scripts that are ready to be executed together with their parameters."
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -