📄 modulenametoip.bas
字号:
Attribute VB_Name = "ModuleNameToIP"
Option Explicit
Declare Sub CopyMemory Lib "kernel32" Alias "RtlMoveMemory" (hpvDest As Any, ByVal hpvSource As Long, ByVal cbCopy As Long)
Public Const SOCKET_ERROR As Long = -1
Public Const MAX_WSADescription = 256
Public Const MAX_WSASYSStatus = 128
Public Const ERROR_SUCCESS As Long = 0
Public Const WS_VERSIon_REQD As Long = &H101
Public Const MIN_SOCKETS_REQD As Long = 1
Public Const WS_VERSIon_MAJOR As Long = WS_VERSIon_REQD \ &H100 And &HFF&
Public Const WS_VERSIon_MINOR As Long = WS_VERSIon_REQD And &HFF&
Public Type HOSTENT
hName As Long
hAliases As Long
hAddrType As Integer
hLen As Integer
hAddrList As Long
End Type
Public Type WSADATA
wVersion As Integer
wHighVersion As Integer
szDescription(0 To MAX_WSADescription) As Byte
szSystemStatus(0 To MAX_WSASYSStatus) As Byte
wMaxSockets As Integer
wMaxUDPDG As Integer
dwVendorInfo As Long
End Type
Declare Function gethostname Lib "WSOCK32.DLL" (ByVal szHost As String, ByVal dwHostLen As Long) As Long
Declare Function gethostbyname Lib "WSOCK32.DLL" (ByVal szHost As String) As Long
Declare Function WSAStartup Lib "WSOCK32.DLL" (ByVal wVersionRequired As Long, lpWSADATA As WSADATA) As Long
Declare Function WSAGetLastError Lib "WSOCK32.DLL" () As Long
Declare Function WSACleanup Lib "WSOCK32.DLL" () As Long
Public Declare Function NetMessageBufferSend Lib "NETAPI32.DLL" (Server As Any, yToname As Byte, yFromName As Any, yMsg As Byte, ByVal lSize As Long) As Long
'调用的时候直接Msgbox GetIPAddress("机器名")即可,如机器名为空,则显示本机IP
Public Function GetIPAddress(Optional sHost As String) As String
Dim sHostName As String * 256
Dim lpHost As Long
Dim HOST As HOSTENT
Dim dwIPAddr As Long
Dim tmpIPAddr() As Byte
Dim I As Integer
Dim sIPAddr As String
Dim werr As Long
If Not SocketsInitialize() Then
GetIPAddress = ""
Exit Function
End If
If sHost = "" Then
If gethostname(sHostName, 256) = SOCKET_ERROR Then
werr = WSAGetLastError()
GetIPAddress = ""
SocketsCleanup
Exit Function
End If
sHostName = VBA.Trim$(sHostName)
Else
sHostName = VBA.Trim$(sHost) & VBA.Chr$(0)
End If
lpHost = gethostbyname(sHostName)
If lpHost = 0 Then
werr = WSAGetLastError()
GetIPAddress = ""
SocketsCleanup
Exit Function
End If
CopyMemory HOST, lpHost, Len(HOST)
CopyMemory dwIPAddr, HOST.hAddrList, 4
ReDim tmpIPAddr(1 To HOST.hLen)
CopyMemory tmpIPAddr(1), dwIPAddr, HOST.hLen
For I = 1 To HOST.hLen
sIPAddr = sIPAddr & tmpIPAddr(I) & "."
Next
GetIPAddress = VBA.Mid$(sIPAddr, 1, Len(sIPAddr) - 1)
SocketsCleanup
End Function
Public Function SocketsInitialize(Optional sErr As String) As Boolean
Dim WSAD As WSADATA, sLoByte As String, sHiByte As String
If WSAStartup(WS_VERSIon_REQD, WSAD) <> ERROR_SUCCESS Then
sErr = "The 32-bit Windows Socket is not responding."
SocketsInitialize = False
Exit Function
End If
If WSAD.wMaxSockets < MIN_SOCKETS_REQD Then
sErr = "This application requires a minimum of " & _
CStr(MIN_SOCKETS_REQD) & " supported sockets."
SocketsInitialize = False
Exit Function
End If
If LoByte(WSAD.wVersion) < WS_VERSIon_MAJOR Or _
(LoByte(WSAD.wVersion) = WS_VERSIon_MAJOR And _
HiByte(WSAD.wVersion) < WS_VERSIon_MINOR) Then
sHiByte = CStr(HiByte(WSAD.wVersion))
sLoByte = CStr(LoByte(WSAD.wVersion))
sErr = "Sockets version " & sLoByte & "." & sHiByte & " is not supported by 32-bit Windows Sockets."
SocketsInitialize = False
Exit Function
End If
SocketsInitialize = True
End Function
Public Sub SocketsCleanup()
If WSACleanup() <> ERROR_SUCCESS Then
App.LogEvent "Socket error occurred in Cleanup.", vbLogEventTypeError
End If
End Sub
Public Function HiByte(ByVal wParam As Integer)
HiByte = wParam \ &H1 And &HFF&
End Function
Public Function LoByte(ByVal wParam As Integer)
LoByte = wParam And &HFF&
End Function
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -