📄 set3a.m

📁 Gives all the matlab codes for dynamic simulation of electric machinery by Chee-Mun Ong
💻 M
字号:
% Machine parameter input file SET3A.M
 
% Machine data for 2x3 equivalent circuit model with two
% nonzero coupling inductances in the d-axis rotor circuits

% Machine data for 2x3 equivalent circuit model from
% Canay, I. M., " Determination of the Model Parameters
% of Machines from the Reactance Operators xd(p), xq(p)
% (Evaluation of Standstill Frequency Response Test),"
% IEEE Trans. on energy Conversion, Vol. 8,
% No.2 June 1993, pp. 272- 279.
% Copyright 1993 IEEE

Frated = 60;
Poles = 2;
Vrated =26e3; 
Srated=722.222e6;
rs = 0.004; % estimate, not from above reference 
xls = 0.19;
xpd = 0.346;
xpq = 0.642;

% d-axis circuit parameters
xmd = 1.70;
xd = xmd + xls;
xpr2c = 0.06523;
xpr1c = 0.01925;
xp1c = 0.1055;
xp2c = 0.03076;
xp3c = -0.009134;
rpkd3 = 0.02467;
rpkd2 = 0.01297;
rpf = 0.00112;

% q-axis circuit parameters
xmq = 1.61;
xq = xmq + xls;
xplkq3 = 0.1225;
xplkq2 = 0.3248;
xplkq1 = 0.6802;
rpkq3 = 0.2237;
rpkq2 = 0.03537;
rpkq1 = 0.005698;

H = 3.; % estimate, not from above reference
Domega = 0; % mechanical damping coeff