📄 fl_thesis_00_2phase.mdl
字号:
InputSameDT on
LogicOutDataTypeMode "Logical (see Configuration Parameters: Optimization)"
LogicDataType "uint(8)"
OutDataTypeStr "Inherit: Logical (see Configuration Parameters: Optimization)"
ZeroCross on
SampleTime "-1"
}
Block {
BlockType Saturate
UpperLimit "0.5"
LowerLimit "-0.5"
LinearizeAsGain on
ZeroCross on
SampleTime "-1"
OutMin "[]"
OutMax "[]"
OutDataTypeMode "Same as input"
OutDataType "fixdt(1,16,0)"
OutScaling "[]"
OutDataTypeStr "Inherit: Same as input"
LockScale off
RndMeth "Floor"
}
Block {
BlockType Sin
SineType "Time based"
TimeSource "Use simulation time"
Amplitude "1"
Bias "0"
Frequency "1"
Phase "0"
Samples "10"
Offset "0"
SampleTime "-1"
VectorParams1D on
}
Block {
BlockType Trigonometry
Operator "sin"
OutputSignalType "auto"
SampleTime "-1"
}
}
AnnotationDefaults {
HorizontalAlignment "center"
VerticalAlignment "middle"
ForegroundColor "black"
BackgroundColor "white"
DropShadow off
FontName "Arial"
FontSize 10
FontWeight "normal"
FontAngle "normal"
UseDisplayTextAsClickCallback off
}
LineDefaults {
FontName "Arial"
FontSize 9
FontWeight "normal"
FontAngle "normal"
}
System {
Name "FL_THESIS_00_2PHASE"
Location [220, 78, 1278, 750]
Open on
ModelBrowserVisibility on
ModelBrowserWidth 218
ScreenColor "white"
PaperOrientation "landscape"
PaperPositionMode "auto"
PaperType "usletter"
PaperUnits "inches"
TiledPaperMargins [0.500000, 0.500000, 0.500000, 0.500000]
TiledPageScale 1
ShowPageBoundaries off
ZoomFactor "100"
ReportName "simulink-default.rpt"
Block {
BlockType Reference
Name "Beban"
Ports [0, 0, 0, 0, 0, 3]
Position [875, 280, 925, 340]
Orientation "down"
AttributesFormatString "\\n"
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Elements/Three-Phase\nParallel RLC Load"
SourceType "Three-Phase Parallel RLC Load"
PhysicalDomain "powersysdomain"
SubClassName "unknown"
LeftPortType "p1"
RightPortType "p1"
LConnTagsString "A|B|C"
Configuration "Y (grounded)"
NominalVoltage "380"
NominalFrequency "50"
ActivePower "2500"
InductivePower "30"
CapacitivePower "0"
Measurements "None"
}
Block {
BlockType Reference
Name "Beban Sensitif\nPeralatan PLC"
Ports [0, 0, 0, 0, 0, 3]
Position [841, 445, 889, 505]
Orientation "down"
AttributesFormatString "\\n"
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Elements/Three-Phase\nParallel RLC Load"
SourceType "Three-Phase Parallel RLC Load"
PhysicalDomain "powersysdomain"
SubClassName "unknown"
LeftPortType "p1"
RightPortType "p1"
LConnTagsString "A|B|C"
Configuration "Y (grounded)"
NominalVoltage "380"
NominalFrequency "50"
ActivePower "2000"
InductivePower "40"
CapacitivePower "10"
Measurements "None"
}
Block {
BlockType Reference
Name "Energy Storage1"
Ports [0, 0, 0, 0, 0, 1, 1]
Position [260, 501, 305, 529]
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Electrical\nSources/DC Voltage Source"
SourceType "DC Voltage Source"
ShowPortLabels "FromPortIcon"
SystemSampleTime "-1"
FunctionWithSeparateData off
RTWMemSecFuncInitTerm "Inherit from model"
RTWMemSecFuncExecute "Inherit from model"
RTWMemSecDataConstants "Inherit from model"
RTWMemSecDataInternal "Inherit from model"
RTWMemSecDataParameters "Inherit from model"
Amplitude "100"
Measurements "None"
}
Block {
BlockType Reference
Name "Energy Storage2"
Ports [0, 0, 0, 0, 0, 1, 1]
Position [260, 586, 305, 614]
Orientation "left"
NamePlacement "alternate"
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Electrical\nSources/DC Voltage Source"
SourceType "DC Voltage Source"
ShowPortLabels "FromPortIcon"
SystemSampleTime "-1"
FunctionWithSeparateData off
RTWMemSecFuncInitTerm "Inherit from model"
RTWMemSecFuncExecute "Inherit from model"
RTWMemSecDataConstants "Inherit from model"
RTWMemSecDataInternal "Inherit from model"
RTWMemSecDataParameters "Inherit from model"
Amplitude "100"
Measurements "None"
}
Block {
BlockType Reference
Name "Gangguan 1"
Ports [0, 0, 0, 0, 0, 3]
Position [585, 100, 625, 160]
NamePlacement "alternate"
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Elements/Three-Phase Fault"
SourceType "Three-Phase Fault"
ShowPortLabels "FromPortIcon"
SystemSampleTime "-1"
FunctionWithSeparateData off
RTWMemSecFuncInitTerm "Inherit from model"
RTWMemSecFuncExecute "Inherit from model"
RTWMemSecDataConstants "Inherit from model"
RTWMemSecDataInternal "Inherit from model"
RTWMemSecDataParameters "Inherit from model"
FaultA on
FaultB on
FaultC off
FaultResistance "0.1"
GroundFault on
GroundResistance "0.1"
External off
SwitchStatus "[1 0 ]"
SwitchTimes "[ 0.019 0.085 ]"
InitialStates "[0 0 1]"
SnubberResistance "1e6"
SnubberCapacitance "inf"
Measurements "None"
}
Block {
BlockType Reference
Name "Ground1"
Ports [0, 0, 0, 0, 0, 1]
Position [185, 549, 210, 571]
Orientation "left"
NamePlacement "alternate"
ShowName off
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Elements/Ground"
SourceType "Ground"
PhysicalDomain "powersysdomain"
SubClassName "unknown"
LeftPortType "p1"
RightPortType "p1"
LConnTagsString "a"
}
Block {
BlockType Reference
Name "Ground2"
Ports [0, 0, 0, 0, 0, 1]
Position [750, 529, 775, 551]
NamePlacement "alternate"
ShowName off
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Elements/Ground"
SourceType "Ground"
PhysicalDomain "powersysdomain"
SubClassName "unknown"
LeftPortType "p1"
RightPortType "p1"
LConnTagsString "a"
}
Block {
BlockType SubSystem
Name "LC Filter"
Ports [0, 0, 0, 0, 0, 3, 3]
Position [480, 531, 510, 609]
MinAlgLoopOccurrences off
PropExecContextOutsideSubsystem off
RTWSystemCode "Auto"
FunctionWithSeparateData off
Opaque off
RequestExecContextInheritance off
MaskHideContents off
System {
Name "LC Filter"
Location [284, 80, 1270, 759]
Open off
ModelBrowserVisibility on
ModelBrowserWidth 200
ScreenColor "white"
PaperOrientation "landscape"
PaperPositionMode "auto"
PaperType "usletter"
PaperUnits "inches"
TiledPaperMargins [0.500000, 0.500000, 0.500000, 0.500000]
TiledPageScale 1
ShowPageBoundaries off
ZoomFactor "100"
Block {
BlockType Reference
Name "6 mH\n0.2 Ohm "
Ports [0, 0, 0, 0, 0, 3, 3]
Position [95, 50, 150, 100]
AttributesFormatString "\\n"
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Elements/Three-Phase\nSeries RLC Branch"
SourceType "Three-Phase Series RLC Branch"
PhysicalDomain "powersysdomain"
SubClassName "unknown"
LeftPortType "p1"
RightPortType "p1"
LConnTagsString "A|B|C"
RConnTagsString "A|B|C"
BranchType "RL"
Resistance "0.2"
Inductance "6e-3"
Capacitance "1.0"
Measurements "None"
}
Block {
BlockType Reference
Name "Ground1"
Ports [0, 0, 0, 0, 0, 1]
Position [194, 220, 216, 245]
Orientation "down"
ShowName off
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Elements/Ground"
SourceType "Ground"
PhysicalDomain "powersysdomain"
SubClassName "unknown"
LeftPortType "p1"
RightPortType "p1"
LConnTagsString "a"
}
Block {
BlockType Reference
Name "Series RLC Branch1"
Ports [0, 0, 0, 0, 0, 1, 1]
Position [194, 145, 216, 165]
Orientation "up"
NamePlacement "alternate"
ShowName off
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Elements/Series RLC Branch"
SourceType "Series RLC Branch"
PhysicalDomain "powersysdomain"
SubClassName "unknown"
LeftPortType "p1"
RightPortType "p1"
LConnTagsString "__new0"
RConnTagsString "__new0"
BranchType "RC"
Resistance "0.2"
Inductance "[]"
SetiL0 off
InitialCurrent "0"
Capacitance "20e-6"
Setx0 off
InitialVoltage "1000"
Measurements "None"
}
Block {
BlockType Reference
Name "Series RLC Branch2"
Ports [0, 0, 0, 0, 0, 1, 1]
Position [209, 145, 231, 165]
Orientation "up"
NamePlacement "alternate"
ShowName off
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Elements/Series RLC Branch"
SourceType "Series RLC Branch"
PhysicalDomain "powersysdomain"
SubClassName "unknown"
LeftPortType "p1"
RightPortType "p1"
LConnTagsString "__new0"
RConnTagsString "__new0"
BranchType "RC"
Resistance "0.2"
Inductance "[]"
SetiL0 off
InitialCurrent "0"
Capacitance "20e-6"
Setx0 off
InitialVoltage "1000"
Measurements "None"
}
Block {
BlockType Reference
Name "Series RLC Branch5"
Ports [0, 0, 0, 0, 0, 1, 1]
Position [179, 145, 201, 165]
Orientation "up"
NamePlacement "alternate"
ShowName off
DialogController "POWERSYS.PowerSysDialog"
SourceBlock "powerlib/Elements/Series RLC Branch"
SourceType "Series RLC Branch"
PhysicalDomain "powersysdomain"
SubClassName "unknown"
LeftPortType "p1"
RightPortType "p1"
LConnTagsString "__new0"
RConnTagsString "__new0"
BranchType "RC"
Resistance "0.2"
Inductance "[]"
SetiL0 off
InitialCurrent "0"
Capacitance "20e-6"
Setx0 off
InitialVoltage "1000"
Measurements "None"
}
Block {
BlockType PMIOPort
Name "A"
Position [25, 28, 55, 42]
Port "1"
Side "Left"
}
Block {
BlockType PMIOPort
Name "B"
Position [25, 68, 55, 82]
Port "2"
Side "Left"
}
Block {
BlockType PMIOPort
Name "C"
Position [20, 108, 50, 122]
Port "3"
Side "Left"
}
Block {
BlockType PMIOPort
Name "A "
Position [285, 28, 315, 42]
Orientation "left"
Port "4"
Side "Right"
}
Block {
BlockType PMIOPort
Name "B "
Position [285, 68, 315, 82]
Orientation "left"
Port "5"
Side "Right"
}
Block {
BlockType PMIOPort
Name "C "
Position [285, 108, 315, 122]
Orientation "left"
Port "6"
Side "Right"
}
Line {
LineType "Connection"
SrcBlock "B"
SrcPort RConn1
DstBlock "6 mH\n0.2 Ohm "
DstPort LConn2
}
Line {
LineType "Connection"
SrcBlock "A"
SrcPort RConn1
Points [0, 25]
DstBlock "6 mH\n0.2 Ohm "
DstPort LConn1
}
Line {
LineType "Connection"
SrcBlock "C"
SrcPort RConn1
Points [10, 0; 0, -25]
DstBlock "6 mH\n0.2 Ohm "
DstPort LConn3
}
Line {
LineType "Connection"
Points [190, 60; 0, 70]
DstBlock "Series RLC Branch5"
DstPort RConn1
Branch {
ConnectType "SRC_SRC"
Points [20, 0; 40, 0; 0, -25]
DstBlock "A "
DstPort RConn1
}
Branch {
ConnectType "SRC_SRC"
DstBlock "6 mH\n0.2 Ohm "
DstPort RConn1
}
}
Line {
LineType "Connection"
SrcBlock "B "
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -