📄 host-resources-mib.txt
字号:
hrStorageAllocationFailures OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of requests for storage represented by
this entry that could not be honored due to not enough
storage. It should be noted that as this object has a
SYNTAX of Counter32, that it does not have a defined
initial value. However, it is recommended that this
object be initialized to zero, even though management
stations must not depend on such an initialization."
::= { hrStorageEntry 7 }
-- The Host Resources Device Group
--
-- The device group is useful for identifying and diagnosing the
-- devices on a system. The hrDeviceTable contains common
-- information for any type of device. In addition, some devices
-- have device-specific tables for more detailed information. More
-- such tables may be defined in the future for other device types.
-- Registration point for device types, for use with hrDeviceType.
-- These are defined in the HOST-RESOURCES-TYPES module.
hrDeviceTypes OBJECT IDENTIFIER ::= { hrDevice 1 }
hrDeviceTable OBJECT-TYPE
SYNTAX SEQUENCE OF HrDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The (conceptual) table of devices contained by the
host."
::= { hrDevice 2 }
hrDeviceEntry OBJECT-TYPE
SYNTAX HrDeviceEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A (conceptual) entry for one device contained by the
host. As an example, an instance of the hrDeviceType
object might be named hrDeviceType.3"
INDEX { hrDeviceIndex }
::= { hrDeviceTable 1 }
HrDeviceEntry ::= SEQUENCE {
hrDeviceIndex Integer32,
hrDeviceType AutonomousType,
hrDeviceDescr DisplayString,
hrDeviceID ProductID,
hrDeviceStatus INTEGER,
hrDeviceErrors Counter32
}
hrDeviceIndex OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value for each device contained by the host.
The value for each device must remain constant at
least from one re-initialization of the agent to the
next re-initialization."
::= { hrDeviceEntry 1 }
hrDeviceType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An indication of the type of device.
If this value is
`hrDeviceProcessor { hrDeviceTypes 3 }' then an entry
exists in the hrProcessorTable which corresponds to
this device.
If this value is
`hrDeviceNetwork { hrDeviceTypes 4 }', then an entry
exists in the hrNetworkTable which corresponds to this
device.
If this value is
`hrDevicePrinter { hrDeviceTypes 5 }', then an entry
exists in the hrPrinterTable which corresponds to this
device.
If this value is
`hrDeviceDiskStorage { hrDeviceTypes 6 }', then an
entry exists in the hrDiskStorageTable which
corresponds to this device."
::= { hrDeviceEntry 2 }
hrDeviceDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of this device, including the
device's manufacturer and revision, and optionally,
its serial number."
::= { hrDeviceEntry 3 }
hrDeviceID OBJECT-TYPE
SYNTAX ProductID
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product ID for this device."
::= { hrDeviceEntry 4 }
hrDeviceStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
running(2),
warning(3),
testing(4),
down(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of the device described
by this row of the table. A value unknown(1)
indicates that the current state of the device is
unknown. running(2) indicates that the device is up
and running and that no unusual error conditions are
known. The warning(3) state indicates that agent has
been informed of an unusual error condition by the
operational software (e.g., a disk device driver) but
that the device is still 'operational'. An example
would be a high number of soft errors on a disk. A
value of testing(4), indicates that the device is not
available for use because it is in the testing state.
The state of down(5) is used only when the agent has
been informed that the device is not available for any
use."
::= { hrDeviceEntry 5 }
hrDeviceErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of errors detected on this device. It
should be noted that as this object has a SYNTAX of
Counter32, that it does not have a defined initial
value. However, it is recommended that this object be
initialized to zero, even though management stations
must not depend on such an initialization."
::= { hrDeviceEntry 6 }
hrProcessorTable OBJECT-TYPE
SYNTAX SEQUENCE OF HrProcessorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The (conceptual) table of processors contained by the
host.
Note that this table is potentially sparse: a
(conceptual) entry exists only if the correspondent
value of the hrDeviceType object is
`hrDeviceProcessor'."
::= { hrDevice 3 }
hrProcessorEntry OBJECT-TYPE
SYNTAX HrProcessorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A (conceptual) entry for one processor contained by
the host. The hrDeviceIndex in the index represents
the entry in the hrDeviceTable that corresponds to the
hrProcessorEntry.
As an example of how objects in this table are named,
an instance of the hrProcessorFrwID object might be
named hrProcessorFrwID.3"
INDEX { hrDeviceIndex }
::= { hrProcessorTable 1 }
HrProcessorEntry ::= SEQUENCE {
hrProcessorFrwID ProductID,
hrProcessorLoad Integer32
}
hrProcessorFrwID OBJECT-TYPE
SYNTAX ProductID
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The product ID of the firmware associated with the
processor."
::= { hrProcessorEntry 1 }
hrProcessorLoad OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average, over the last minute, of the percentage
of time that this processor was not idle.
Implementations may approximate this one minute
smoothing period if necessary."
::= { hrProcessorEntry 2 }
hrNetworkTable OBJECT-TYPE
SYNTAX SEQUENCE OF HrNetworkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The (conceptual) table of network devices contained
by the host.
Note that this table is potentially sparse: a
(conceptual) entry exists only if the correspondent
value of the hrDeviceType object is
`hrDeviceNetwork'."
::= { hrDevice 4 }
hrNetworkEntry OBJECT-TYPE
SYNTAX HrNetworkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A (conceptual) entry for one network device contained
by the host. The hrDeviceIndex in the index
represents the entry in the hrDeviceTable that
corresponds to the hrNetworkEntry.
As an example of how objects in this table are named,
an instance of the hrNetworkIfIndex object might be
named hrNetworkIfIndex.3"
INDEX { hrDeviceIndex }
::= { hrNetworkTable 1 }
HrNetworkEntry ::= SEQUENCE {
hrNetworkIfIndex InterfaceIndexOrZero
}
hrNetworkIfIndex OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ifIndex which corresponds to this
network device. If this device is not represented in
the ifTable, then this value shall be zero."
::= { hrNetworkEntry 1 }
hrPrinterTable OBJECT-TYPE
SYNTAX SEQUENCE OF HrPrinterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The (conceptual) table of printers local to the host.
Note that this table is potentially sparse: a
(conceptual) entry exists only if the correspondent
value of the hrDeviceType object is
`hrDevicePrinter'."
::= { hrDevice 5 }
hrPrinterEntry OBJECT-TYPE
SYNTAX HrPrinterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A (conceptual) entry for one printer local to the
host. The hrDeviceIndex in the index represents the
entry in the hrDeviceTable that corresponds to the
hrPrinterEntry.
As an example of how objects in this table are named,
an instance of the hrPrinterStatus object might be
named hrPrinterStatus.3"
INDEX { hrDeviceIndex }
::= { hrPrinterTable 1 }
HrPrinterEntry ::= SEQUENCE {
hrPrinterStatus INTEGER,
hrPrinterDetectedErrorState OCTET STRING
}
hrPrinterStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
idle(3),
printing(4),
warmup(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of this printer device."
::= { hrPrinterEntry 1 }
hrPrinterDetectedErrorState OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object represents any error conditions detected
by the printer. The error conditions are encoded as
bits in an octet string, with the following
definitions:
Condition Bit #
lowPaper 0
noPaper 1
lowToner 2
noToner 3
doorOpen 4
jammed 5
offline 6
serviceRequested 7
inputTrayMissing 8
outputTrayMissing 9
markerSupplyMissing 10
outputNearFull 11
outputFull 12
inputTrayEmpty 13
overduePreventMaint 14
Bits are numbered starting with the most significant
bit of the first byte being bit 0, the least
significant bit of the first byte being bit 7, the
most significant bit of the second byte being bit 8,
and so on. A one bit encodes that the condition was
detected, while a zero bit encodes that the condition
was not detected.
This object is useful for alerting an operator to
specific warning or error conditions that may occur,
especially those requiring human intervention."
::= { hrPrinterEntry 2 }
hrDiskStorageTable OBJECT-TYPE
SYNTAX SEQUENCE OF HrDiskStorageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The (conceptual) table of long-term storage devices
contained by the host. In particular, disk devices
accessed remotely over a network are not included
here.
Note that this table is potentially sparse: a
(conceptual) entry exists only if the correspondent
value of the hrDeviceType object is
`hrDeviceDiskStorage'."
::= { hrDevice 6 }
hrDiskStorageEntry OBJECT-TYPE
SYNTAX HrDiskStorageEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A (conceptual) entry for one long-term storage device
contained by the host. The hrDeviceIndex in the index
represents the entry in the hrDeviceTable that
corresponds to the hrDiskStorageEntry. As an example,
an instance of the hrDiskStorageCapacity object might
be named hrDiskStorageCapacity.3"
INDEX { hrDeviceIndex }
::= { hrDiskStorageTable 1 }
HrDiskStorageEntry ::= SEQUENCE {
hrDiskStorageAccess INTEGER,
hrDiskStorageMedia INTEGER,
hrDiskStorageRemoveble TruthValue,
hrDiskStorageCapacity KBytes
}
hrDiskStorageAccess OBJECT-TYPE
SYNTAX INTEGER {
readWrite(1),
readOnly(2)
⌨️ 快捷键说明