⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 snmpv2-tc.txt

📁 java聊天软件源码
💻 TXT
📖 第 1 页 / 共 3 页
字号:
SNMPv2-TC DEFINITIONS ::= BEGIN

IMPORTS
    TimeTicks         FROM SNMPv2-SMI;

-- definition of textual conventions

TEXTUAL-CONVENTION MACRO ::=

BEGIN
    TYPE NOTATION ::=
                  DisplayPart
                  "STATUS" Status
                  "DESCRIPTION" Text
                  ReferPart
                  "SYNTAX" Syntax

    VALUE NOTATION ::=
                   value(VALUE Syntax)      -- adapted ASN.1

    DisplayPart ::=
                  "DISPLAY-HINT" Text
                | empty

    Status ::=
                  "current"
                | "deprecated"
                | "obsolete"

    ReferPart ::=
                  "REFERENCE" Text
                | empty

    -- a character string as defined in [2]
    Text ::= value(IA5String)

    Syntax ::=   -- Must be one of the following:
                       -- a base type (or its refinement), or
                       -- a BITS pseudo-type
                  type
                | "BITS" "{" NamedBits "}"

    NamedBits ::= NamedBit
                | NamedBits "," NamedBit

    NamedBit ::=  identifier "(" number ")" -- number is nonnegative

END

DisplayString ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "255a"
    STATUS       current
    DESCRIPTION
            "Represents textual information taken from the NVT ASCII

            character set, as defined in pages 4, 10-11 of RFC 854.

            To summarize RFC 854, the NVT ASCII repertoire specifies:

              - the use of character codes 0-127 (decimal)

              - the graphics characters (32-126) are interpreted as
                US ASCII

              - NUL, LF, CR, BEL, BS, HT, VT and FF have the special
                meanings specified in RFC 854

              - the other 25 codes have no standard interpretation

              - the sequence 'CR LF' means newline

              - the sequence 'CR NUL' means carriage-return

              - an 'LF' not preceded by a 'CR' means moving to the
                same column on the next line.

              - the sequence 'CR x' for any x other than LF or NUL is
                illegal.  (Note that this also means that a string may
                end with either 'CR LF' or 'CR NUL', but not with CR.)

            Any object defined using this syntax may not exceed 255
            characters in length."
    SYNTAX       OCTET STRING (SIZE (0..255))

PhysAddress ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "1x:"
    STATUS       current
    DESCRIPTION
            "Represents media- or physical-level addresses."
    SYNTAX       OCTET STRING

MacAddress ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "1x:"
    STATUS       current
    DESCRIPTION
            "Represents an 802 MAC address represented in the
            `canonical' order defined by IEEE 802.1a, i.e., as if it
            were transmitted least significant bit first, even though
            802.5 (in contrast to other 802.x protocols) requires MAC
            addresses to be transmitted most significant bit first."
    SYNTAX       OCTET STRING (SIZE (6))

TruthValue ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "Represents a boolean value."
    SYNTAX       INTEGER { true(1), false(2) }

TestAndIncr ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "Represents integer-valued information used for atomic
            operations.  When the management protocol is used to specify
            that an object instance having this syntax is to be
            modified, the new value supplied via the management protocol
            must precisely match the value presently held by the
            instance.  If not, the management protocol set operation
            fails with an error of `inconsistentValue'.  Otherwise, if
            the current value is the maximum value of 2^31-1 (2147483647
            decimal), then the value held by the instance is wrapped to
            zero; otherwise, the value held by the instance is
            incremented by one.  (Note that regardless of whether the
            management protocol set operation succeeds, the variable-
            binding in the request and response PDUs are identical.)

            The value of the ACCESS clause for objects having this
            syntax is either `read-write' or `read-create'.  When an
            instance of a columnar object having this syntax is created,
            any value may be supplied via the management protocol.

            When the network management portion of the system is re-
            initialized, the value of every object instance having this
            syntax must either be incremented from its value prior to
            the re-initialization, or (if the value prior to the re-
            initialization is unknown) be set to a pseudo-randomly
            generated value."
    SYNTAX       INTEGER (0..2147483647)

AutonomousType ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "Represents an independently extensible type identification
            value.  It may, for example, indicate a particular sub-tree
            with further MIB definitions, or define a particular type of
            protocol or hardware."
    SYNTAX       OBJECT IDENTIFIER

InstancePointer ::= TEXTUAL-CONVENTION
    STATUS       obsolete
    DESCRIPTION
            "A pointer to either a specific instance of a MIB object or
            a conceptual row of a MIB table in the managed device.  In
            the latter case, by convention, it is the name of the
            particular instance of the first accessible columnar object
            in the conceptual row.

            The two uses of this textual convention are replaced by
            VariablePointer and RowPointer, respectively."
    SYNTAX       OBJECT IDENTIFIER

VariablePointer ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "A pointer to a specific object instance.  For example,
            sysContact.0 or ifInOctets.3."
    SYNTAX       OBJECT IDENTIFIER

RowPointer ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "Represents a pointer to a conceptual row.  The value is the
            name of the instance of the first accessible columnar object
            in the conceptual row.

            For example, ifIndex.3 would point to the 3rd row in the
            ifTable (note that if ifIndex were not-accessible, then
            ifDescr.3 would be used instead)."
    SYNTAX       OBJECT IDENTIFIER

RowStatus ::= TEXTUAL-CONVENTION
    STATUS       current
    DESCRIPTION
            "The RowStatus textual convention is used to manage the
            creation and deletion of conceptual rows, and is used as the
            value of the SYNTAX clause for the status column of a
            conceptual row (as described in Section 7.7.1 of [2].)

            The status column has six defined values:

                 - `active', which indicates that the conceptual row is
                 available for use by the managed device;

                 - `notInService', which indicates that the conceptual
                 row exists in the agent, but is unavailable for use by
                 the managed device (see NOTE below); 'notInService' has
                 no implication regarding the internal consistency of
                 the row, availability of resources, or consistency with
                 the current state of the managed device;

                 - `notReady', which indicates that the conceptual row
                 exists in the agent, but is missing information
                 necessary in order to be available for use by the
                 managed device (i.e., one or more required columns in
                 the conceptual row have not been instanciated);

                 - `createAndGo', which is supplied by a management
                 station wishing to create a new instance of a
                 conceptual row and to have its status automatically set
                 to active, making it available for use by the managed
                 device;

                 - `createAndWait', which is supplied by a management
                 station wishing to create a new instance of a
                 conceptual row (but not make it available for use by
                 the managed device); and,
                 - `destroy', which is supplied by a management station
                 wishing to delete all of the instances associated with
                 an existing conceptual row.

            Whereas five of the six values (all except `notReady') may
            be specified in a management protocol set operation, only
            three values will be returned in response to a management
            protocol retrieval operation:  `notReady', `notInService' or
            `active'.  That is, when queried, an existing conceptual row
            has only three states:  it is either available for use by
            the managed device (the status column has value `active');
            it is not available for use by the managed device, though
            the agent has sufficient information to attempt to make it
            so (the status column has value `notInService'); or, it is
            not available for use by the managed device, and an attempt
            to make it so would fail because the agent has insufficient
            information (the state column has value `notReady').

                                     NOTE WELL

                 This textual convention may be used for a MIB table,
                 irrespective of whether the values of that table's
                 conceptual rows are able to be modified while it is
                 active, or whether its conceptual rows must be taken
                 out of service in order to be modified.  That is, it is
                 the responsibility of the DESCRIPTION clause of the
                 status column to specify whether the status column must
                 not be `active' in order for the value of some other
                 column of the same conceptual row to be modified.  If
                 such a specification is made, affected columns may be
                 changed by an SNMP set PDU if the RowStatus would not
                 be equal to `active' either immediately before or after
                 processing the PDU.  In other words, if the PDU also
                 contained a varbind that would change the RowStatus
                 value, the column in question may be changed if the
                 RowStatus was not equal to `active' as the PDU was
                 received, or if the varbind sets the status to a value
                 other than 'active'.

            Also note that whenever any elements of a row exist, the
            RowStatus column must also exist.

            To summarize the effect of having a conceptual row with a

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -