📄 mca-btl-openib-hca-params.ini
字号:
## Copyright (c) 2006 Cisco Systems, Inc. All rights reserved.# $COPYRIGHT$# # Additional copyrights may follow## This is the default HCA parameters file for Open MPI's OpenIB BTL.# If HCA vendors wish to add their respective values into this file# (that is distributed with Open MPI), please contact the Open MPI# development team. See http://www.open-mpi.org/ for details.# This file is in the "ini" style, meaning that it has sections# identified section names enclosed in square brackets (e.g.,# "[Section name]") followed by "key = value" pairs indicating values# for a specific HCA vendor and model. HCAs are identified by their# vendor ID and vendor part ID, which can be obtained by running the# diagnostic utility command "ibv_devinfo". The fields "vendor_id"# and "vendor_part"id" are the vendor ID and vendor part ID,# respectively.# The sections in this file only accept a few fields:# vendor_id: a comma-delimited list of integers of HCA vendor IDs,# expressed either in decimal or hexidecimal (e.g., "13" or "0xd").# Individual values can be taken directly from the output of# "ibv_devinfo". HCA vendor ID's correspond to IEEE OUI's, for which# you can find the canonical list here:# http://standards.ieee.org/regauth/oui/. Example:## vendor_id = 0x05ad# vendor_part_id: a comma-delimited list of integers of different HCA# models from a single vendor, expressed in either decimal or# hexidecimal (e.g., "13" or "0xd"). Individual values can be# obtained from the output of the "ibv_devinfo". Example:## vendor_part_id = 25208,25218# mtu: an integer indicating the maximum transfer unit (MTU) to be# used with this HCA. The effective MTU will be the minimum of an# HCA's MTU value and its peer HCA's MTU value. Valid values are 256,# 512, 1024, 2048, and 4096. Example:## mtu = 1024# use_eager_rdma: an integer indicating whether RDMA should be used# for eager messages. 0 values indicate "no" (false); non-zero values# indicate "yes" (true). This flag should only be enabled for# HCAs that can provide guarantees about ordering of data in memory --# that the last byte of an incoming packet will always be written# last. Certain cards cannot provide this guarantee (such as iWARP# cards), while others can (such as many InfiniBand cards). # use_eager_rdma = 1############################################################################[default]# These are the default values, identified by the vendor and part ID# numbers of 0 and 0. If queried HCA does not return vendor and part# ID numbers that match any of the sections in this file, the values# in this section are used. Vendor IDs and part IDs can be hex or# decimal.vendor_id = 0vendor_part_id = 0use_eager_rdma = 0mtu = 1024############################################################################[Mellanox Tavor Infinihost]# Several vendors resell Mellanox hardware and put their own firmware# on the cards, therefore overriding the default Mellanox vendor ID.## Mellanox 0x02c9# Cisco 0x05ad# Silverstorm 0x066a# Voltaire 0x08f1# HP 0x1708#vendor_id = 0x2c9,0x5ad,0x66a,0x8f1,0x1708vendor_part_id = 23108use_eager_rdma = 1mtu = 1024############################################################################[Mellanox Arbel InfiniHost III MemFree/Tavor]vendor_id = 0x2c9,0x5ad,0x66a,0x8f1,0x1708vendor_part_id = 25208,25218use_eager_rdma = 1mtu = 1024############################################################################[Mellanox Sinai Infinihost III]vendor_id = 0x2c9,0x5ad,0x66a,0x8f1,0x1708vendor_part_id = 25204use_eager_rdma = 1mtu = 2048############################################################################# A.k.a. ConnectX[Mellanox Hermon]vendor_id = 0x2c9,0x5ad,0x66a,0x8f1,0x1708vendor_part_id = 25408,25418,25428use_eager_rdma = 1mtu = 2048############################################################################[IBM eHCA 4x and 12x ]vendor_id = 0x5076vendor_part_id = 0use_eager_rdma = 1mtu = 2048############################################################################[QLogic InfiniPath]vendor_id = 0x1fc1vendor_part_id = 13,16use_eager_rdma = 1mtu = 2048
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -