MicroCANopen Example Implementation
===================================
CONTAINS: Example application using MicroCANopen
Tested with Fujitsu Softune Workbench
On PEAK-System Technik MicroMod
COPYRIGHT: Embedded Systems Academy, Inc. 2002 - 2007
All rights reserved. www.microcanopen.com
This software was written in accordance to the guidelines at
www.esacademy.com/software/softwarestyleguide.pdf
DISCLAIM: Read and understand our disclaimer before using this code!
www.esacademy.com/disclaim.htm
LICENSE: THIS IS THE EDUCATIONAL VERSION OF MICROCANOPEN
See file license_educational.txt or
www.microcanopen.com/license_educational.txt
A commercial MicroCANopen license is available at
www.CANopenStore.com
VERSION: 3.30, ESA 30-JAN-07
Implementation Description
==========================
Node-ID: 7
Baudrate: 125kbit
Messages generated:
0x707 - Heartbeat
Send every 2 seconds
0x187 - TPDO1 - Four bytes of digital inputs.
All bytes copied/echoed from the digital output value
received in RPDO1.
Transmit Trigger: 300ms event time and change of state (COS)
with 20ms inhibit time
0x287 - TPDO2 - Two 16-bit analog inputs. The first value is the potentiometer.
The second value is copied from the analog output value
received in RPDO2.
Transmit Trigger: 200ms event time and change of state (COS)
with 50ms inhibit time
Messages received:
0x000 - NMT Master command message
0x207 - RPDO1 - Four bytes of digital outputs.
All bytes copied to TPDO1 (echo mode).
0x307 - RPDO2 - Two 16-bit analog outputs. The first value is ignored. The
second value is copied to TPDO2.
Note on CANopen Conformance
The commercial version of MicroCANopen passes the CANopen
conformance test with some limitations:
a) The available version of the conformance test (2.0.02) can not
correctly deal with nodes that only support heartbeat and have no
node guarding.
b) The conformance test offers limited flexibility in regards to
pre-configured nodes. In order for an EDS to pass the check, many
defaults are expected to be zero. However, pre-configured nodes
typically do not use zeros for event and other timers.