Release 9.1i par J.30Copyright (c) 1995-2006 Xilinx, Inc.  All rights reserved.GAVIN::  Tue Dec 12 08:56:55 2006par -w -ol high -xe n D:/ise_book/Example-4-1/xplorer/run2_map.ncd
D:/ise_book/Example-4-1/xplorer/run2.ncd
D:/ise_book/Example-4-1/xplorer/run2.pcf Constraints file: D:/ise_book/Example-4-1/xplorer/run2.pcf.Loading device for application Rf_Device from file '3s400.nph' in environment D:\Xilinx91i.   "counter" is an NCD, version 3.1, device xc3s400, package pq208, speed -4Initializing temperature to 85.000 Celsius. (default - Range: 0.000 to 85.000 Celsius)Initializing voltage to 1.140 Volts. (default - Range: 1.140 to 1.260 Volts)Device speed data version:  "PRODUCTION 1.39 2006-10-19".INFO:Par:253 - The Map -timing placement will be retained since it is likely to achieve better performance.Device Utilization Summary:   Number of BUFGMUXs                        1 out of 8      12%   Number of External IOBs                  19 out of 141    13%      Number of LOCed IOBs                   0 out of 19      0%   Number of Slices                         19 out of 3584    1%      Number of SLICEMs                      0 out of 1792    0%Overall effort level (-ol):   High Router effort level (-rl):    High Starting initial Timing Analysis.  REAL time: 5 secs Finished initial Timing Analysis.  REAL time: 5 secs Starting RouterPhase 1: 151 unrouted;       REAL time: 6 secs Phase 2: 131 unrouted;       REAL time: 6 secs Phase 3: 20 unrouted;       REAL time: 6 secs Phase 4: 20 unrouted; (16)      REAL time: 6 secs Phase 5: 20 unrouted; (16)      REAL time: 6 secs Phase 6: 20 unrouted; (16)      REAL time: 6 secs Phase 7: 0 unrouted; (877)      REAL time: 6 secs Phase 8: 0 unrouted; (877)      REAL time: 6 secs Updating file: D:/ise_book/Example-4-1/xplorer/run2.ncd with current fully routed design.Phase 9: 0 unrouted; (526)      REAL time: 7 secs Phase 10: 0 unrouted; (526)      REAL time: 7 secs Phase 11: 0 unrouted; (526)      REAL time: 8 secs Updating file: D:/ise_book/Example-4-1/xplorer/run2.ncd with current fully routed design.Phase 12: 0 unrouted; (526)      REAL time: 10 secs Phase 13: 0 unrouted; (526)      REAL time: 13 secs Phase 14: 0 unrouted; (526)      REAL time: 13 secs Phase 15: 0 unrouted; (526)      REAL time: 13 secs WARNING:Route:447 - CLK Net:clk_BUFGP may have excessive skew because    19 CLK pins failed to route using a CLK template.Total REAL time to Router completion: 13 secs Total CPU time to Router completion: 13 secs Partition Implementation Status-------------------------------  No Partitions were found in this design.-------------------------------Generating "PAR" statistics.**************************Generating Clock Report**************************+---------------------+--------------+------+------+------------+-------------+|        Clock Net    |   Resource   |Locked|Fanout|Net Skew(ns)|Max Delay(ns)|+---------------------+--------------+------+------+------------+-------------+|           clk_BUFGP |      BUFGMUX0| No   |   19 |  0.001     |  1.015      |+---------------------+--------------+------+------+------------+-------------+* Net Skew is the difference between the minimum and maximum routingonly delays for the net. Note this is different from Clock Skew whichis reported in TRCE timing report. Clock Skew is the difference betweenthe minimum and maximum path delays which includes logic delays.   The Delay Summary ReportThe NUMBER OF SIGNALS NOT COMPLETELY ROUTED for this design is: 0   The AVERAGE CONNECTION DELAY for this design is:        1.515   The MAXIMUM PIN DELAY IS:                               4.001   The AVERAGE CONNECTION DELAY on the 10 WORST NETS is:   2.699   Listing Pin Delays by value: (nsec)    d < 1.00   < d < 2.00  < d < 3.00  < d < 4.00  < d < 5.00  d >= 5.00   ---------   ---------   ---------   ---------   ---------   ---------          56          38          45          10           1           0Timing Score: 526WARNING:Par:62 - Your design did not meet timing.  The following are some suggestions to assist you to meet timing in
   your design.      Review the timing report using Timing Analyzer (In ISE select "Post-Place &      Route Static Timing Report").  Go to the failing constraint(s) and select      the "Timing Improvement Wizard" link for suggestions to correct each problem.   Run Multi-Pass Place and Route in PAR using at least 5 "PAR Iterations"   (ISE process "Multi Pass Place & Route").   Use the Xilinx "xplorer" script to try special combinations of   options known to produce very good results.   See http://www.xilinx.com/ise/implementation/Xplorer.htm for details.   Visit the Xilinx technical support web at http://support.xilinx.com and go to   either "Troubleshoot->Tech Tips->Timing & Constraints" or "   TechXclusives->Timing Closure" for tips and suggestions for meeting timing   in your design.Asterisk (*) preceding a constraint indicates it was not met.   This may be due to a setup or hold violation.------------------------------------------------------------------------------------------------------  Constraint                                |  Check  | Worst Case |  Best Case | Timing |   Timing                                               |         |    Slack   | Achievable | Errors |    Score   ------------------------------------------------------------------------------------------------------* TS_clk = PERIOD TIMEGRP "clk" 5.45238095  | SETUP   |    -0.201ns|     5.653ns|       4|         526  ns HIGH 50%                               | HOLD    |     1.456ns|            |       0|           0------------------------------------------------------------------------------------------------------1 constraint not met.Generating Pad Report.All signals are completely routed.Total REAL time to PAR completion: 14 secs Total CPU time to PAR completion: 14 secs Peak Memory Usage:  136 MBPlacer: Placement generated during map.Routing: Completed - No errors found.Timing: Completed - 4 errors found.Number of error messages: 0Number of warning messages: 2Number of info messages: 1Writing design to file D:/ise_book/Example-4-1/xplorer/run2.ncdPAR done!

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -