📄 agilent_mxa_v0.92.mdd
字号:
</Property> <Property> <Name>ModeOpts</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand/> <QueryCommand>:INST:CAT?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>String</Type> <Constraint>none</Constraint> </PermissibleType> <DefaultValue/> <ReadOnly>always</ReadOnly> <Description>Queries the instrument mode options</Description> </Property> <Property> <Name>PeakExcur</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:CALC:MARK:PEAK:EXC</ConfigureCommand> <QueryCommand>:CALC:MARK:PEAK:EXC?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>Double</Type> <Constraint>none</Constraint> </PermissibleType> <DefaultValue>0</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the peak excursion value</Description> </Property> <Property> <Name>PeakThres</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:CALC:MARK:PEAK:THR</ConfigureCommand> <QueryCommand>:CALC:MARK:PEAK:THR?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>Double</Type> <Constraint>none</Constraint> </PermissibleType> <DefaultValue>0</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the peak threshold value</Description> </Property> <Property> <Name>Preamp</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:POW:GAIN</ConfigureCommand> <QueryCommand>:POW:GAIN?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>String</Type> <Constraint>enum</Constraint> <ConstraintValue> <Enum Name="on" Value="1"/> <Enum Name="off" Value="0"/> </ConstraintValue> </PermissibleType> <DefaultValue>off</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the RF internal preamplifier state</Description> </Property> <Property> <Name>PresetType</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:SYST:PRES:TYPE</ConfigureCommand> <QueryCommand>:SYST:PRES:TYPE?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>String</Type> <Constraint>enum</Constraint> <ConstraintValue> <Enum Name="factory" Value="FACT"/> <Enum Name="user" Value="USER"/> <Enum Name="mode" Value="MODE"/> </ConstraintValue> </PermissibleType> <DefaultValue>mode</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the instrument preset mode</Description> </Property> <Property> <Name>RefLevel</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:DISP:WIND:TRAC:Y:RLEV</ConfigureCommand> <QueryCommand>:DISP:WIND:TRAC:Y:RLEV?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>Double</Type> <Constraint>none</Constraint> </PermissibleType> <DefaultValue>0</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the frequency span</Description> </Property> <Property> <Name>ResBW</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:BAND</ConfigureCommand> <QueryCommand>:BAND?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>Double</Type> <Constraint>bounded</Constraint> <ConstraintValue> <Range Max="8000000.0" Min="1.0"/> </ConstraintValue> </PermissibleType> <DefaultValue>3e6</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the resolution bandwidth</Description> </Property> <Property> <Name>ResBWAuto</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:BAND:AUTO</ConfigureCommand> <QueryCommand>:BAND:AUTO?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>String</Type> <Constraint>enum</Constraint> <ConstraintValue> <Enum Name="on" Value="1"/> <Enum Name="off" Value="0"/> </ConstraintValue> </PermissibleType> <DefaultValue>on</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the resolution bandwidth auto mode</Description> </Property> <Property> <Name>RFCoup</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:INP:COUP</ConfigureCommand> <QueryCommand>:INP:COUP?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>String</Type> <Constraint>enum</Constraint> <ConstraintValue> <Enum Name="ac" Value="AC"/> <Enum Name="dc" Value="DC"/> </ConstraintValue> </PermissibleType> <DefaultValue>ac</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the RF input coupling</Description> </Property> <Property> <Name>ScaleDiv</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:DISP:WIND:TRAC:Y:PDIV</ConfigureCommand> <QueryCommand>:DISP:WIND:TRAC:Y:PDIV?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>Double</Type> <Constraint>bounded</Constraint> <ConstraintValue> <Range Max="20.0" Min="0.1"/> </ConstraintValue> </PermissibleType> <DefaultValue>10</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the logarithmic units per vertical graticule division on the display</Description> </Property> <Property> <Name>ScaleType</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:DISP:WIND:TRAC:Y:SPAC</ConfigureCommand> <QueryCommand>:DISP:WIND:TRAC:Y:SPAC?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>String</Type> <Constraint>enum</Constraint> <ConstraintValue> <Enum Name="lin" Value="LIN"/> <Enum Name="log" Value="LOG"/> </ConstraintValue> </PermissibleType> <DefaultValue>log</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the vertical scale type for the display</Description> </Property> <Property> <Name>Span</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:FREQ:SPAN</ConfigureCommand> <QueryCommand>:FREQ:SPAN?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>Double</Type> <Constraint>none</Constraint> </PermissibleType> <DefaultValue>2e9</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the frequency span</Description> </Property> <Property> <Name>StartFreq</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:FREQ:STAR</ConfigureCommand> <QueryCommand>:FREQ:STAR?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>Double</Type> <Constraint>bounded</Constraint> <ConstraintValue> <Range Max="2.7E10" Min="-1.0E8"/> </ConstraintValue> </PermissibleType> <DefaultValue>0.0</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the start frequency</Description> </Property> <Property> <Name>StopFreq</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:FREQ:STOP</ConfigureCommand> <QueryCommand>:FREQ:STOP?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>Double</Type> <Constraint>bounded</Constraint> <ConstraintValue> <Range Max="2.7E10" Min="-1.0E8"/> </ConstraintValue> </PermissibleType> <DefaultValue>2e9</DefaultValue> <ReadOnly>never</ReadOnly> <Description>Sets or queries the stop frequency</Description> </Property> <Property> <Name>SweepPoints</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:SWE:POIN</ConfigureCommand> <QueryCommand>:SWE:POIN?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>Double</Type> <Constraint>none</Constraint> </PermissibleType> <DefaultValue>1001</DefaultValue> <ReadOnly>always</ReadOnly> <Description>Queries the number of trace points</Description> </Property> <Property> <Name>SweepTime</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>InstrumentCommand</Type> <Code> <Commands> <ConfigureCommand>:SWE:TIME</ConfigureCommand> <QueryCommand>:SWE:TIME?</QueryCommand> </Commands> </Code> <PermissibleType> <Type>Double</Type> <Constraint>none</Constraint> </PermissibleType> <DefaultValue>0</DefaultValue> <ReadOnly>always</ReadOnly> <Description>Queries the trace sweep time</Description> </Property> <Property> <Name>Time</Name> <Location>parent</Location> <CapabilityGroup>Base</CapabilityGroup> <Type>MCode</Type> <Code> <GetMCode>function propertyValue = getProperty(obj, propertyName)% Return a property value.% This function is called to return the device or group object property% value. If the property is a group property, OBJ is the group object. If% the property is a base device property, OBJ is the device object.interface = get(obj, 'Interface');time = query(interface, ':SYST:TIME?');coma_idx = find(time == ',');hour = time(1:coma_idx(1)-1);minute = time(coma_idx(1)+1:coma_idx(2)-1);sec = time(coma_idx(2)+1:end-1);propertyValue = [hour 'h ' minute 'm ' sec 's'];</GetMCode> <SetMCode>function set(obj, propertyName, propertyValue)% Set a property value.% This function is called to set the device or group object property% value. If the property is a group property, OBJ is the group object. If% the property is a base device property, OBJ is the device object.</SetMCode> </Code> <PermissibleType> <Type>String</Type> <Constraint>none</Constraint> </PermissibleType> <DefaultValue/> <ReadOnly>always</ReadOnly> <Description>Queries the instrument time</Description> </Property> <Property>
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -