c393a02.a
来自「用于进行gcc测试」· A 代码 · 共 214 行
A
214 行
-- C393A02.A---- Grant of Unlimited Rights---- Under contracts F33600-87-D-0337, F33600-84-D-0280, MDA903-79-C-0687,-- F08630-91-C-0015, and DCA100-97-D-0025, the U.S. Government obtained -- unlimited rights in the software and documentation contained herein.-- Unlimited rights are defined in DFAR 252.227-7013(a)(19). By making -- this public release, the Government intends to confer upon all -- recipients unlimited rights equal to those held by the Government. -- These rights include rights to use, duplicate, release or disclose the -- released technical data and computer software in whole or in part, in -- any manner and for any purpose whatsoever, and to have or permit others -- to do so.---- DISCLAIMER---- ALL MATERIALS OR INFORMATION HEREIN RELEASED, MADE AVAILABLE OR-- DISCLOSED ARE AS IS. THE GOVERNMENT MAKES NO EXPRESS OR IMPLIED -- WARRANTY AS TO ANY MATTER WHATSOEVER, INCLUDING THE CONDITIONS OF THE-- SOFTWARE, DOCUMENTATION OR OTHER INFORMATION RELEASED, MADE AVAILABLE -- OR DISCLOSED, OR THE OWNERSHIP, MERCHANTABILITY, OR FITNESS FOR A-- PARTICULAR PURPOSE OF SAID MATERIAL.--*---- OBJECTIVE:-- Check that a dispatching call to an abstract subprogram invokes-- the correct subprogram body of a descendant type according to-- the controlling tag.-- Check that a subprogram can be declared with formal parameters-- and result that are of an abstract type's associated class-wide-- type and that such subprograms can be called. 3.4.1(4)---- TEST DESCRIPTION:-- This test declares several objects of types derived from the-- abstract type as defined in the foundation F393A00. It then calls-- various dispatching and class-wide subprograms using those objects.-- The packages in F393A00 are instrumented to trace the flow of-- execution.-- The test checks for the correct order of execution, as expected-- by the various calls.---- TEST FILES:-- The following files comprise this test:---- F393A00.A (foundation code)-- C393A02.A------ CHANGE HISTORY:-- 06 Dec 94 SAIC ACVC 2.0-- 19 Dec 94 SAIC Removed RM references from objective text.-- 05 APR 96 SAIC Update RM references for 2.1----!with Report;with F393A00_0;with F393A00_1;with F393A00_2;with F393A00_3;with F393A00_4;procedure C393A02 is A_Windmill : F393A00_2.Windmill; A_Pump : F393A00_3.Pump; A_Mill : F393A00_4.Mill; A_Windmill_2 : F393A00_2.Windmill; A_Pump_2 : F393A00_3.Pump; A_Mill_2 : F393A00_4.Mill; B_Windmill : F393A00_2.Windmill; B_Pump : F393A00_3.Pump; B_Mill : F393A00_4.Mill; procedure Swapem( A,B: in out F393A00_2.Windmill'Class ) is begin F393A00_0.TC_Touch('x'); F393A00_2.Swap( A,B ); end Swapem; function Zephyr( A: F393A00_2.Windmill'Class ) return F393A00_2.Windmill'Class is Item : F393A00_2.Windmill'Class := A; begin F393A00_0.TC_Touch('y'); if not F393A00_1.Initialized( Item ) then -- b F393A00_2.Initialize( Item ); -- a end if; F393A00_2.Stop( Item ); -- f / mff F393A00_2.Add_Spin( Item, 10 ); -- e return Item; end Zephyr; function Gale( It: F393A00_2.Windmill ) return F393A00_2.Windmill'Class is Item : F393A00_2.Windmill'Class := It; begin F393A00_2.Stop( Item ); -- f F393A00_2.Add_Spin( Item, 40 ); -- e return Item; end Gale; function Gale( It: F393A00_3.Pump ) return F393A00_2.Windmill'Class is Item : F393A00_2.Windmill'Class := It; begin F393A00_2.Stop( Item ); -- f F393A00_2.Add_Spin( Item, 50 ); -- e return Item; end Gale; function Gale( It: F393A00_4.Mill ) return F393A00_2.Windmill'Class is Item : F393A00_2.Windmill'Class := It; begin F393A00_2.Stop( Item ); -- mff F393A00_2.Add_Spin( Item, 60 ); -- e return Item; end Gale;begin -- Main test procedure. Report.Test ("C393A02", "Check that a dispatching call to an abstract " & "subprogram invokes the correct subprogram body. " & "Check that a subprogram declared with formal " & "parameters/result of an abstract type's " & "associated class-wide can be called" ); F393A00_0.TC_Validate( "hhh", "Mill declarations" ); A_Windmill := F393A00_2.Create; F393A00_0.TC_Validate( "d", "Create A_Windmill" ); A_Pump := F393A00_3.Create; F393A00_0.TC_Validate( "h", "Create A_Pump" ); A_Mill := F393A00_4.Create; F393A00_0.TC_Validate( "hl", "Create A_Mill" ); -------------- Swapem( A_Windmill, A_Windmill_2 ); F393A00_0.TC_Validate( "xc", "Windmill Swap" ); Swapem( A_Pump, A_Pump_2 ); F393A00_0.TC_Validate( "xc", "Pump Swap" ); Swapem( A_Mill, A_Mill_2 ); F393A00_0.TC_Validate( "xk", "Pump Swap" ); F393A00_2.Initialize( A_Windmill_2 ); F393A00_3.Initialize( A_Pump_2 ); F393A00_4.Initialize( A_Mill_2 ); B_Windmill := A_Windmill_2; B_Pump := A_Pump_2; B_Mill := A_Mill_2; F393A00_2.Add_Spin( B_Windmill, 123 ); F393A00_3.Set_Rate( B_Pump, 12.34 ); F393A00_4.Add_Spin( B_Mill, 321 ); F393A00_0.TC_Validate( "aaaeie", "Setting Values" ); declare It : F393A00_2.Windmill'Class := Zephyr( B_Windmill ); -- ybfe XX : F393A00_2.Windmill'Class := Gale( B_Windmill ); -- fe use type F393A00_2.Rotational_Measurement; begin if not F393A00_1.Initialized( It ) or not F393A00_1.Initialized( XX )then Report.Failed( "Copy to class-wide variable" ); end if; -- bb if F393A00_2.Spin( It ) /= 10 -- g or F393A00_2.Spin( XX ) /= 40 then -- g Report.Failed( "Call to class-wide operation" ); end if; F393A00_0.TC_Validate( "ybfefebbgg", "Windmill Zephyr" ); end; declare It : F393A00_2.Windmill'Class := Zephyr( B_Pump ); -- ybfe XX : F393A00_2.Windmill'Class := Gale( B_Pump ); -- fe use type F393A00_2.Rotational_Measurement; begin if not F393A00_1.Initialized( It ) or not F393A00_1.Initialized( XX )then Report.Failed( "Bad copy to class-wide variable" ); end if; -- bb if F393A00_2.Spin( It ) /= 10 -- g or F393A00_2.Spin( XX ) /= 50 then -- g Report.Failed( "Call to class-wide operation" ); end if; F393A00_0.TC_Validate( "ybfefebbgg", "Pump Zephyr" ); end; declare It : F393A00_2.Windmill'Class := Zephyr( B_Mill ); -- ybmffe XX : F393A00_2.Windmill'Class := Gale( B_Mill ); -- mffe use type F393A00_2.Rotational_Measurement; begin if not F393A00_1.Initialized( It ) or not F393A00_1.Initialized( XX )then Report.Failed( "Bad copy to class-wide variable" ); end if; -- bb if F393A00_2.Spin( It ) /= 10 -- g or F393A00_2.Spin( XX ) /= 60 then -- g Report.Failed( "Call to class-wide operation" ); end if; F393A00_0.TC_Validate( "ybmffemffebbgg", "Mill Zephyr" ); end; Report.Result;end C393A02;
⌨️ 快捷键说明
复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?