表址设置 BB BB 79 79 79 4F 4B 0D
表址设置 BB BB 80 80 80 4F 4B 0D
查询日期时间 7955012005f40D (55012005累加=7B)
应答:79 4F 4B 0D 79 AA 01 20 05 04 01 06 12 19 7F 0D
表址 O K 结束码 表址命令标志字 标志地址低 高 数据长度(=5?) 年 月 日 时 分 累加和 结束码
查询日期时间 82 55 01 20 05 FD 0D (55012005累加=7B)
0.版本查询 01 55 C2 10 01 29 0D
灯塔-上冈窑1: 01 4F 4B 0D 01 AA C2 10 01 2C AA 0D
办公室NO.3279: 01 4F 4B 0D 01 A5 C2 10 01 03 7C 0D (A5表示有报警)
密码广播 BD BD FE 00 00 00 00 78 0D
密码设置 79 55 03 22 05 fe 00 00 00 00 f6 0D 01 55 03 22 05 fe 00 00 00 00 7E 0D
跳闸 79 AA 20 20 00 63 0D 01 AA 20 20 00 EB 0D
1. 打包查询命令79 B8 6D FF B8 6D 86 C2 0D 79 8B D6 30 30 30 30 30 30 30 30 30 30 30 30 32 30 30 30 30 30 30 30 45 31 32 35 30 30 30 30 30 30 30 30 30 30 30 30 39 38 31 31 30 30 30 30 36 34 30 45 30 30 30 30 35 39 30 30 30 30 30 30 32 44 30 31 30 30 30 30 58 10 0D
//86是异或和,C2是累加和
2. 打包查询命令 79B86DFF0000539D0D
应答:79 8B D6 30 30 30 30 30 30 30 30 30 30 30 30 32 30 30 30 30 30 30 30 35 36 32 37 30 30 30 30 30 30 30 30 30 30 30 30 39 38 31 31 30 30 30 30 36 34 30 45 30 30 30 30 35 39 30 30 30 30 30 30 32 44 30 31 30 30 30 30 2D 7 D
广播对时 BC BC 05 03 1C 10 0C B8 0D 无
设置日期时间79 AA 01 20 05 05 03 1C 10 30 AD 0D 无
设置日期时间82 AA 01 20 05 05 04 16 11 05 87 0D 无
打包查询命令 01B86DFF00002B250D
(TCP) 211.136.72.121:55320 Bytes: 74
1 8B D6
30 30 30 30 30 30
30 30 30 30 30 30
41 38 30 32 30 30 30 30 37 37 32 35
30 30 30 30 30 30 30 30 30 30 30 30
44 36 35 34 30 30 30 30
45 35 31 34 30 30 30 30
30 37 30 30 30 30 30 30
30 30 30 30 30 30 30 30
21 9B D
7. 电量冻结方式
01 55 24 20 01 9B 0D
灯塔-上冈窑1: 查不到
办公室NO.3279: 01 4F 4B 0D 01 A5 24 20 01 13 03 05 0D 0B 11 17 07 FF FF FF FF FF FF 01 00 01 00 01 01 07 00 00 30 2C 21 C2 11 B2 22 FC 13 85 0D
8. 冻结电量查询
01 55 00 11 55 BC 0D
socket (724) sending data synchronously without blocking [len=7]
socket (724) sent 7 bytes of data
0000 01 55 00 11 55 BC 0D .U..U..
socket (724) receiving data synchronously without blocking [len=8192]
socket (724) received 96 bytes of data
0000 01 4F 4B 0D 01 AA 00 11 55 00 00 00 00 00 00 00 .OK.....U.......
0010 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
0020 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
0030 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
0040 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
0050 00 00 00 00 00 00 00 00 00 00 00 00 00 FF 10 0D ................
01 55 00 11 85 EC 0D
0000 01 4F 4B 0D 01 AA 00 11 85 00 00 00 00 00 00 00 .OK.............
0010 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
0020 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
0030 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
0040 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ................
0050 00 00 00 00 00 00 00 00 00 00 00 00 00 FF 16 7C ...............|
0060 00 00 0B 2F 00 00 CF 39 00 00 3C 13 00 00 00 00 .../...9..<.....
0070 00 00 BB 12 01 00 19 6D 00 00 E5 82 00 00 BD 22 .......m......."
0080 00 00 00 00 00 00 64 01 00 00 5C 00 00 00 BE 0D ......d...\.....
9. 全部数据打包查询
9.1 总电量数据 01C79A4000001CA20D
1 7C A9 31 //瞬时量为30,总电量为31,上月电量为36
44 36 35 34 30 30 30 30 //54D6:有功总:21718 W(除以1000,转成千瓦:kw)
33 46 31 43 30 30 30 30 //1C3F:峰:7231 W
43 43 32 37 30 30 30 30 //27CC:平:10188
43 42 31 30 30 30 30 30 //10CB:谷:4299
30 30 30 30 30 30 30 30 //尖:0
45 35 31 34 30 30 30 30 //14E5:无功总:5349
45 41 30 35 30 30 30 30 //峰
43 37 30 38 30 30 30 30 //平
33 34 30 36 30 30 30 30 //谷
30 30 30 30 30 30 30 30 //尖
30 37 30 30 30 30 30 30 //容性无功
30 30 30 30 30 30 30 30
30 37 30 30 30 30 30 30
30 30 30 30 30 30 30 30
30 30 30 30 30 30 30 30
30 30 30 30 30 30 30 30 //反向有功
30 30 30 30 30 30 30 30
30 30 30 30 30 30 30 30
30 30 30 30 30 30 30 30
30 30 30 30 30 30 30 30
49 //校验和1:异或
5D //校验和2:累加
1 //实际发送的包数
D //结束码
9.2 上月电量数据 01 C7 9A 02 00 00 5E 64 0D
01 7C A9 36
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
30 30 30 30 30 30
36
B6
01
0D
10.参数设置命令
01 AA 24 20 01 00 F0 0D
11.电量冻结广播命令
F0 F1 F2 F3 00 C6 0D
12.密码广播命令
BD BD FE 00 00 00 00 78 0D
13.密码设置命令
01 AA 03 22 05 FE 00 00 00 00 D3 0D
ANS:01 4F 4B 0D
14.串口设置开通命令
01 AA 02 22 05 F0 00 00 00 00 C4 0D
ANS:01 4F 4B 0D
15.串口设置关闭命令
01 AA 01 22 05 00 00 00 00 00 D3 0D
ANS:01 4F 4B 0D
16. 电量冻结命令
01 AA 24 20 01 00 F0 0D
ANS:01 4F 4B 0D