⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 opt-if-mib

📁 很不错java的SNMP应用例子
💻
📖 第 1 页 / 共 5 页
字号:
  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION    "A table of OTSn sink performance monitoring information for     the current 24-hour interval."  ::= { optIfOTSn 4 }optIfOTSnSinkCurDayEntry OBJECT-TYPE  SYNTAX  OptIfOTSnSinkCurDayEntry  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION    "A conceptual row that contains OTSn sink performance     monitoring information of an interface for the current     24-hour interval."  INDEX  { ifIndex }  ::= { optIfOTSnSinkCurDayTable 1 }OptIfOTSnSinkCurDayEntry ::=  SEQUENCE {    optIfOTSnSinkCurDaySuspectedFlag    TruthValue,    optIfOTSnSinkCurDayLowInputPower    Integer32,    optIfOTSnSinkCurDayHighInputPower   Integer32,    optIfOTSnSinkCurDayLowOutputPower   Integer32,    optIfOTSnSinkCurDayHighOutputPower  Integer32    }optIfOTSnSinkCurDaySuspectedFlag OBJECT-TYPE  SYNTAX  TruthValue  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "If true, the data in this entry may be unreliable."  ::= { optIfOTSnSinkCurDayEntry 1 }optIfOTSnSinkCurDayLowInputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The lowest optical power monitored at the input during the     current 24-hour interval."  ::= { optIfOTSnSinkCurDayEntry 2 }optIfOTSnSinkCurDayHighInputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The highest optical power monitored at the input during the     current 24-hour interval."  ::= { optIfOTSnSinkCurDayEntry 3 }optIfOTSnSinkCurDayLowOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The lowest optical power monitored at the output during the     current 24-hour interval."  ::= { optIfOTSnSinkCurDayEntry 4 }optIfOTSnSinkCurDayHighOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The highest optical power monitored at the output during the     current 24-hour interval."  ::= { optIfOTSnSinkCurDayEntry 5 }-- OTSn sink previous day table-- Contains data for the previous 24-hour performance-- monitoring interval.optIfOTSnSinkPrevDayTable OBJECT-TYPE  SYNTAX  SEQUENCE OF OptIfOTSnSinkPrevDayEntry  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION    "A table of OTSn sink performance monitoring information for     the previous 24-hour interval."  ::= { optIfOTSn 5 }optIfOTSnSinkPrevDayEntry OBJECT-TYPE  SYNTAX  OptIfOTSnSinkPrevDayEntry  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION    "A conceptual row that contains OTSn sink performance     monitoring information of an interface for the previous     24-hour interval."  INDEX  { ifIndex }  ::= { optIfOTSnSinkPrevDayTable 1 }OptIfOTSnSinkPrevDayEntry ::=  SEQUENCE {    optIfOTSnSinkPrevDaySuspectedFlag    TruthValue,    optIfOTSnSinkPrevDayLastInputPower   Integer32,    optIfOTSnSinkPrevDayLowInputPower    Integer32,    optIfOTSnSinkPrevDayHighInputPower   Integer32,    optIfOTSnSinkPrevDayLastOutputPower  Integer32,    optIfOTSnSinkPrevDayLowOutputPower   Integer32,    optIfOTSnSinkPrevDayHighOutputPower  Integer32    }optIfOTSnSinkPrevDaySuspectedFlag OBJECT-TYPE  SYNTAX  TruthValue  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "If true, the data in this entry may be unreliable."  ::= { optIfOTSnSinkPrevDayEntry 1 }optIfOTSnSinkPrevDayLastInputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The last optical power monitored at the input during the     previous 24-hour interval."  ::= { optIfOTSnSinkPrevDayEntry 2 }optIfOTSnSinkPrevDayLowInputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The lowest optical power monitored at the input during the     previous 24-hour interval."  ::= { optIfOTSnSinkPrevDayEntry 3 }optIfOTSnSinkPrevDayHighInputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The highest optical power monitored at the input during the     previous 24-hour interval."  ::= { optIfOTSnSinkPrevDayEntry 4 }optIfOTSnSinkPrevDayLastOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The last optical power monitored at the output during the     previous 24-hour interval."  ::= { optIfOTSnSinkPrevDayEntry 5 }optIfOTSnSinkPrevDayLowOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The lowest optical power monitored at the output during the     previous 24-hour interval."  ::= { optIfOTSnSinkPrevDayEntry 6 }optIfOTSnSinkPrevDayHighOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The highest optical power monitored at the output during the     previous 24-hour interval."  ::= { optIfOTSnSinkPrevDayEntry 7 }-- OTSn source current table-- Contains data for the current 15-minute performance monitoring-- interval.optIfOTSnSrcCurrentTable OBJECT-TYPE  SYNTAX  SEQUENCE OF OptIfOTSnSrcCurrentEntry  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION    "A table of OTSn source performance monitoring information for     the current 15-minute interval."  ::= { optIfOTSn 6 }optIfOTSnSrcCurrentEntry OBJECT-TYPE  SYNTAX  OptIfOTSnSrcCurrentEntry  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION    "A conceptual row that contains OTSn source performance     monitoring information of an interface for the current     15-minute interval."  INDEX  { ifIndex }  ::= { optIfOTSnSrcCurrentTable 1 }OptIfOTSnSrcCurrentEntry ::=  SEQUENCE {    optIfOTSnSrcCurrentSuspectedFlag              TruthValue,    optIfOTSnSrcCurrentOutputPower                Integer32,    optIfOTSnSrcCurrentLowOutputPower             Integer32,    optIfOTSnSrcCurrentHighOutputPower            Integer32,    optIfOTSnSrcCurrentLowerOutputPowerThreshold  Integer32,    optIfOTSnSrcCurrentUpperOutputPowerThreshold  Integer32,    optIfOTSnSrcCurrentInputPower                 Integer32,    optIfOTSnSrcCurrentLowInputPower              Integer32,    optIfOTSnSrcCurrentHighInputPower             Integer32,    optIfOTSnSrcCurrentLowerInputPowerThreshold   Integer32,    optIfOTSnSrcCurrentUpperInputPowerThreshold   Integer32    }optIfOTSnSrcCurrentSuspectedFlag OBJECT-TYPE  SYNTAX  TruthValue  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "If true, the data in this entry may be unreliable."  ::= { optIfOTSnSrcCurrentEntry 1 }optIfOTSnSrcCurrentOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The optical power monitored at the output."  ::= { optIfOTSnSrcCurrentEntry 2 }optIfOTSnSrcCurrentLowOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The lowest optical power monitored at the output during the     current 15-minute interval."  ::= { optIfOTSnSrcCurrentEntry 3 }optIfOTSnSrcCurrentHighOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The highest optical power monitored at the output during the     current 15-minute interval."  ::= { optIfOTSnSrcCurrentEntry 4 }optIfOTSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-write  STATUS  current  DESCRIPTION    "The lower limit threshold on output power.  If     optIfOTSnSrcCurrentOutputPower drops to this value or below,     a Threshold Crossing Alert (TCA) should be sent."  ::= { optIfOTSnSrcCurrentEntry 5 }optIfOTSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-write  STATUS  current  DESCRIPTION    "The upper limit threshold on output power.  If     optIfOTSnSrcCurrentOutputPower reaches or exceeds this value,     a Threshold Crossing Alert (TCA) should be sent."  ::= { optIfOTSnSrcCurrentEntry 6 }optIfOTSnSrcCurrentInputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The optical power monitored at the input."  ::= { optIfOTSnSrcCurrentEntry 7 }optIfOTSnSrcCurrentLowInputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The lowest optical power monitored at the input during the     current 15-minute interval."  ::= { optIfOTSnSrcCurrentEntry 8 }optIfOTSnSrcCurrentHighInputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The highest optical power monitored at the input during the     current 15-minute interval."  ::= { optIfOTSnSrcCurrentEntry 9 }optIfOTSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-write  STATUS  current  DESCRIPTION    "The lower limit threshold on input power.  If     optIfOTSnSrcCurrentInputPower drops to this value or below,     a Threshold Crossing Alert (TCA) should be sent."  ::= { optIfOTSnSrcCurrentEntry 10 }optIfOTSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-write  STATUS  current  DESCRIPTION    "The upper limit threshold on input power.  If     optIfOTSnSrcCurrentInputPower reaches or exceeds this value,     a Threshold Crossing Alert (TCA) should be sent."  ::= { optIfOTSnSrcCurrentEntry 11 }-- OTSn source interval table-- Contains data for previous 15-minute performance monitoring-- intervals.optIfOTSnSrcIntervalTable OBJECT-TYPE  SYNTAX  SEQUENCE OF OptIfOTSnSrcIntervalEntry  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION    "A table of historical OTSn source performance monitoring     information."  ::= { optIfOTSn 7 }optIfOTSnSrcIntervalEntry OBJECT-TYPE  SYNTAX  OptIfOTSnSrcIntervalEntry  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION    "A conceptual row that contains OTSn source performance     monitoring information of an interface during a particular     historical interval."  INDEX  { ifIndex, optIfOTSnSrcIntervalNumber }  ::= { optIfOTSnSrcIntervalTable 1 }OptIfOTSnSrcIntervalEntry ::=  SEQUENCE {    optIfOTSnSrcIntervalNumber           OptIfIntervalNumber,    optIfOTSnSrcIntervalSuspectedFlag    TruthValue,    optIfOTSnSrcIntervalLastOutputPower  Integer32,    optIfOTSnSrcIntervalLowOutputPower   Integer32,    optIfOTSnSrcIntervalHighOutputPower  Integer32,    optIfOTSnSrcIntervalLastInputPower   Integer32,    optIfOTSnSrcIntervalLowInputPower    Integer32,    optIfOTSnSrcIntervalHighInputPower   Integer32    }optIfOTSnSrcIntervalNumber OBJECT-TYPE  SYNTAX  OptIfIntervalNumber  MAX-ACCESS  not-accessible  STATUS  current  DESCRIPTION    "Uniquely identifies the interval."  ::= { optIfOTSnSrcIntervalEntry 1 }optIfOTSnSrcIntervalSuspectedFlag OBJECT-TYPE  SYNTAX  TruthValue  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "If true, the data in this entry may be unreliable."  ::= { optIfOTSnSrcIntervalEntry 2 }optIfOTSnSrcIntervalLastOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The last optical power monitored at the output during the     interval."  ::= { optIfOTSnSrcIntervalEntry 3 }optIfOTSnSrcIntervalLowOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The lowest optical power monitored at the output during the     interval."  ::= { optIfOTSnSrcIntervalEntry 4 }optIfOTSnSrcIntervalHighOutputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The highest optical power monitored at the output during the     interval."  ::= { optIfOTSnSrcIntervalEntry 5 }optIfOTSnSrcIntervalLastInputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only  STATUS  current  DESCRIPTION    "The last optical power monitored at the input during the     interval."  ::= { optIfOTSnSrcIntervalEntry 6 }optIfOTSnSrcIntervalLowInputPower OBJECT-TYPE  SYNTAX  Integer32  UNITS  "0.1 dbm"  MAX-ACCESS  read-only

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -