⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 tokenring-mib

📁 很不错java的SNMP应用例子
💻
📖 第 1 页 / 共 2 页
字号:
            field A bits are set to 1 indicating a            possible line hit or duplicate address."    ::= { dot5StatsEntry 9 }dot5StatsTokenErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "This counter is incremented when a station            acting as the active monitor recognizes an            error condition that needs a token            transmitted."    ::= { dot5StatsEntry 10 }dot5StatsSoftErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of Soft Errors the interface            has detected. It directly corresponds to            the number of Report Error MAC frames            that this interface has transmitted.            Soft Errors are those which are            recoverable by the MAC layer protocols."    ::= { dot5StatsEntry 11 }dot5StatsHardErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times this interface has            detected an immediately recoverable            fatal error.  It denotes the number of            times this interface is either            transmitting or receiving beacon MAC            frames."    ::= { dot5StatsEntry 12 }dot5StatsSignalLoss OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times this interface has            detected the loss of signal condition from            the ring."    ::= { dot5StatsEntry 13 }dot5StatsTransmitBeacons OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times this interface has            transmitted a beacon frame."    ::= { dot5StatsEntry 14 }dot5StatsRecoverys OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of Claim Token MAC frames            received or transmitted after the interface            has received a Ring Purge MAC frame.  This            counter signifies the number of times the            ring has been purged and is being recovered            back into a normal operating state."    ::= { dot5StatsEntry 15 }dot5StatsLobeWires OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times the interface has            detected an open or short circuit in the            lobe data path.  The adapter will be closed            and dot5RingState will signify this            condition."    ::= { dot5StatsEntry 16 }dot5StatsRemoves OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times the interface has            received a Remove Ring Station MAC frame            request.  When this frame is received            the interface will enter the close state            and dot5RingState will signify this            condition."    ::= { dot5StatsEntry 17 }dot5StatsSingles OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times the interface has            sensed that it is the only station on the            ring.  This will happen if the interface            is the first one up on a ring, or if            there is a hardware problem."    ::= { dot5StatsEntry 18 }dot5StatsFreqErrors OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION            "The number of times the interface has            detected that the frequency of the            incoming signal differs from the expected            frequency by more than that specified by            the IEEE 802.5 standard."    ::= { dot5StatsEntry 19 }-- The Timer Table-- This group contains the values of timers for 802.5-- interfaces.  This table is obsolete, but its definition-- is retained here for backwards compatibility.dot5TimerTable  OBJECT-TYPE    SYNTAX      SEQUENCE OF Dot5TimerEntry    MAX-ACCESS  not-accessible    STATUS      obsolete    DESCRIPTION            "This table contains Token Ring interface            timer values, one entry per 802.5            interface."    ::= { dot5 5 }dot5TimerEntry  OBJECT-TYPE    SYNTAX      Dot5TimerEntry    MAX-ACCESS  not-accessible    STATUS      obsolete    DESCRIPTION            "A list of Token Ring timer values for an            802.5 interface."    INDEX       { dot5TimerIfIndex }    ::= { dot5TimerTable 1 }Dot5TimerEntry ::= SEQUENCE {    dot5TimerIfIndex          Integer32,    dot5TimerReturnRepeat     Integer32,    dot5TimerHolding          Integer32,    dot5TimerQueuePDU         Integer32,    dot5TimerValidTransmit    Integer32,    dot5TimerNoToken          Integer32,    dot5TimerActiveMon        Integer32,    dot5TimerStandbyMon       Integer32,    dot5TimerErrorReport      Integer32,    dot5TimerBeaconTransmit   Integer32,    dot5TimerBeaconReceive    Integer32}dot5TimerIfIndex  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The value of this object identifies the             802.5 interface for which this entry             contains timer values.  The value of             this object for a particular interface             has the same value as MIB-II's ifIndex             object for the same interface."    ::= { dot5TimerEntry 1 }dot5TimerReturnRepeat  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value used to ensure the            interface will return to Repeat State, in            units of 100 micro-seconds.  The value            should be greater than the maximum ring            latency."    ::= { dot5TimerEntry 2 }dot5TimerHolding  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "Maximum period of time a station is            permitted to transmit frames after capturing            a token, in units of 100 micro-seconds."    ::= { dot5TimerEntry 3 }dot5TimerQueuePDU  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value for enqueuing of an SMP            PDU after reception of an AMP or SMP            frame in which the A and C bits were            equal to 0, in units of 100            micro-seconds."    ::= { dot5TimerEntry 4 }dot5TimerValidTransmit OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value used by the active            monitor to detect the absence of valid            transmissions, in units of 100            micro-seconds."    ::= { dot5TimerEntry 5 }dot5TimerNoToken  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value used to recover from            various-related error situations.            If N is the maximum number of stations on            the ring, the value of this timer is            normally:            dot5TimerReturnRepeat + N*dot5TimerHolding."    ::= { dot5TimerEntry 6 }dot5TimerActiveMon  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value used by the active            monitor to stimulate the enqueuing of an            AMP PDU for transmission, in units of            100 micro-seconds."    ::= { dot5TimerEntry 7 }dot5TimerStandbyMon  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value used by the stand-by            monitors to ensure that there is an active            monitor on the ring and to detect a            continuous stream of tokens, in units of            100 micro-seconds."    ::= { dot5TimerEntry 8 }dot5TimerErrorReport  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value which determines how            often a station shall send a Report Error            MAC frame to report its error counters,            in units of 100 micro-seconds."    ::= { dot5TimerEntry 9 }dot5TimerBeaconTransmit  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value which determines how            long a station shall remain in the state            of transmitting Beacon frames before            entering the Bypass state, in units of            100 micro-seconds."    ::= { dot5TimerEntry 10 }dot5TimerBeaconReceive  OBJECT-TYPE    SYNTAX      Integer32    MAX-ACCESS  read-only    STATUS      obsolete    DESCRIPTION            "The time-out value which determines how            long a station shall receive Beacon            frames from its downstream neighbor            before entering the Bypass state, in            units of 100 micro-seconds."    ::= { dot5TimerEntry 11 }--                802.5 Interface Testsdot5Tests   OBJECT IDENTIFIER ::= { dot5 3 }-- RFC 1573 defines the ifTestTable, through which a-- network manager can instruct an agent to test an interface-- for various faults.  A test to be performed is identified-- as an OBJECT IDENTIFIER.-- The Insert Function testdot5TestInsertFunc  OBJECT-IDENTITY    STATUS       current    DESCRIPTION        "Invoking this test causes the station to test the insert        ring logic of the hardware if the station's lobe media        cable is connected to a wiring concentrator.  Note that        this command inserts the station into the network, and        thus, could cause problems if the station is connected        to a operational network."    ::= { dot5Tests 1 }-- The Full-Duplex Loop Back testdot5TestFullDuplexLoopBack OBJECT-IDENTITY    STATUS       current    DESCRIPTION        "Invoking this test on a 802.5 interface causes the        interface to check the path from memory through the        chip set's internal logic and back to memory, thus        checking the proper functioning of the system's        interface to the chip set."    ::= { dot5Tests 2 }--              802.5 Hardware Chip Sets-- RFC 1229 specified an object, ifExtnsChipSet, with the-- syntax of OBJECT IDENTIFIER, to identify the hardware-- chip set in use by an interface.  RFC 1573 obsoletes-- the use of ifExtnsChipSet.  However, the following-- definitions are retained for backwards compatibility.dot5ChipSets   OBJECT IDENTIFIER ::= { dot5 4 }dot5ChipSetIBM16  OBJECT-IDENTITY    STATUS        current    DESCRIPTION        "IBM's 16/4 Mbs chip set."    ::= { dot5ChipSets 1 }dot5ChipSetTItms380 OBJECT-IDENTITY    STATUS        current    DESCRIPTION        "Texas Instruments' TMS 380 4Mbs chip-set"    ::= { dot5ChipSets 2 }dot5ChipSetTItms380c16 OBJECT-IDENTITY    STATUS        current    DESCRIPTION        "Texas Instruments' TMS 380C16 16/4 Mbs chip-set"    ::= { dot5ChipSets 3 }-- conformance informationdot5Conformance OBJECT IDENTIFIER ::= { dot5 6 }dot5Groups      OBJECT IDENTIFIER ::= { dot5Conformance 1 }dot5Compliances OBJECT IDENTIFIER ::= { dot5Conformance 2 }-- compliance statementsdot5Compliance MODULE-COMPLIANCE    STATUS  current    DESCRIPTION        "The compliance statement for SNMPv2 entities        which implement the IEEE 802.5 MIB."    MODULE  -- this module        MANDATORY-GROUPS { dot5StateGroup, dot5StatsGroup }        OBJECT     dot5ActMonParticipate        MIN-ACCESS read-only        DESCRIPTION            "Write access is not required."        OBJECT     dot5Functional        MIN-ACCESS read-only        DESCRIPTION            "Write access is not required."    ::= { dot5Compliances 1 }-- units of conformancedot5StateGroup  OBJECT-GROUP    OBJECTS   { dot5Commands, dot5RingStatus, dot5RingState,                dot5RingOpenStatus, dot5RingSpeed, dot5UpStream,                dot5ActMonParticipate, dot5Functional,                dot5LastBeaconSent              }    STATUS    current    DESCRIPTION        "A collection of objects providing state information        and parameters for IEEE 802.5 interfaces."    ::= { dot5Groups 1 }dot5StatsGroup  OBJECT-GROUP    OBJECTS   { dot5StatsLineErrors, dot5StatsBurstErrors,                dot5StatsACErrors, dot5StatsAbortTransErrors,                dot5StatsInternalErrors, dot5StatsLostFrameErrors,                dot5StatsReceiveCongestions,                dot5StatsFrameCopiedErrors, dot5StatsTokenErrors,                dot5StatsSoftErrors, dot5StatsHardErrors,                dot5StatsSignalLoss, dot5StatsTransmitBeacons,                dot5StatsRecoverys, dot5StatsLobeWires,                dot5StatsRemoves, dot5StatsSingles,                dot5StatsFreqErrors              }    STATUS    current    DESCRIPTION        "A collection of objects providing statistics for        IEEE 802.5 interfaces."    ::= { dot5Groups 2 }END

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -