⭐ 欢迎来到虫虫下载站! | 📦 资源下载 📁 资源专辑 ℹ️ 关于我们
⭐ 虫虫下载站

📄 sip-mib

📁 很不错java的SNMP应用例子
💻
📖 第 1 页 / 共 3 页
字号:
       "The number of received SIP Level 2 PDUs that are       BOMs for which an active receive process is       already started."    ::= { sipL2Entry 7 }sipL2BomOrSSMsMIDErrors  OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "The number of received SIP Level 2 PDUs that are       SSMs with a MID not equal to zero or are BOMs with       MIDs equal to zero."    ::= { sipL2Entry 8 }sipL2EomsMIDErrors  OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "The number of received SIP Level 2 PDUs that are       EOMs for which there is no active receive process       for the MID (i.e., the receipt of an EOM which       does not correspond to a BOM) OR the EOM has a MID       equal to zero."    ::= { sipL2Entry 9 }-- The SIP PLCP GroupsipPLCP OBJECT IDENTIFIER ::= { sip 3 }-- The DS1 PLCP GroupsipDS1PLCPTable  OBJECT-TYPE    SYNTAX      SEQUENCE OF SipDS1PLCPEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION       "This table contains SIP DS1 PLCP parameters and       state variables, one entry per SIP port."    ::= { sipPLCP 1 }sipDS1PLCPEntry  OBJECT-TYPE    SYNTAX      SipDS1PLCPEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION       "This list contains SIP DS1 PLCP parameters and       state variables."    INDEX   { sipDS1PLCPIndex }    ::= { sipDS1PLCPTable 1 }SipDS1PLCPEntry  ::= SEQUENCE {    sipDS1PLCPIndex       IfIndex,    sipDS1PLCPSEFSs       Counter32,    sipDS1PLCPAlarmState  INTEGER,    sipDS1PLCPUASs        Counter32    }sipDS1PLCPIndex  OBJECT-TYPE    SYNTAX      IfIndex    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "The value of this object identifies the       interface for which this entry contains management       information. "    ::= { sipDS1PLCPEntry 1 }sipDS1PLCPSEFSs OBJECT-TYPE    SYNTAX       Counter32    MAX-ACCESS   read-only    STATUS       current    DESCRIPTION       "A DS1 Severely Errored Framing Second (SEFS) is a       count of one-second intervals containing one or       more SEF events.  A Severely Errored Framing (SEF)       event is declared when an error in the A1 octet       and an error in the A2 octet of a framing octet       pair (i.e., errors in both framing octets), or two       consecutive invalid and/or nonsequential Path       Overhead Identifier octets are detected."    ::= { sipDS1PLCPEntry 2 }sipDS1PLCPAlarmState OBJECT-TYPE    SYNTAX  INTEGER     {                noAlarm (1),                receivedFarEndAlarm (2),                incomingLOF (3)            }    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "This variable indicates if there is an alarm       present for the DS1 PLCP.  The value       receivedFarEndAlarm means that the DS1 PLCP has       received an incoming Yellow Signal, the value       incomingLOF means that the DS1 PLCP has declared a       loss of frame (LOF) failure condition, and the       value noAlarm means that there are no alarms       present.  See TR-TSV-000773 for a description of       alarm states."    ::= { sipDS1PLCPEntry 3 }sipDS1PLCPUASs OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "The counter associated with the number of       Unavailable Seconds, as defined by TR-TSV-000773,       encountered by the PLCP."    ::= { sipDS1PLCPEntry 4 }-- The DS3 PLCP GroupsipDS3PLCPTable  OBJECT-TYPE    SYNTAX      SEQUENCE OF SipDS3PLCPEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION       "This table contains SIP DS3 PLCP parameters and       state variables, one entry per SIP port."    ::= { sipPLCP 2 }sipDS3PLCPEntry  OBJECT-TYPE    SYNTAX      SipDS3PLCPEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION       "This list contains SIP DS3 PLCP parameters and       state variables."    INDEX   { sipDS3PLCPIndex }    ::= { sipDS3PLCPTable 1 }SipDS3PLCPEntry  ::= SEQUENCE {    sipDS3PLCPIndex       IfIndex,    sipDS3PLCPSEFSs       Counter32,    sipDS3PLCPAlarmState  INTEGER,    sipDS3PLCPUASs        Counter32    }sipDS3PLCPIndex  OBJECT-TYPE    SYNTAX      IfIndex    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "The value of this object identifies the       interface for which this entry contains management       information.  "    ::= { sipDS3PLCPEntry 1 }sipDS3PLCPSEFSs OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "A DS3 Severely Errored Framing Second (SEFS) is a       count of one-second intervals containing one or       more SEF events.  A Severely Errored Framing (SEF)       event is declared when an error in the A1 octet       and an error in the A2 octet of a framing octet       pair (i.e., errors in both framing octets), or two       consecutive invalid and/or nonsequential Path       Overhead Identifier octets are detected."    ::= { sipDS3PLCPEntry 2 }sipDS3PLCPAlarmState OBJECT-TYPE    SYNTAX  INTEGER     {                noAlarm (1),                receivedFarEndAlarm (2),                incomingLOF (3)            }    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "This variable indicates if there is an alarm       present for the DS3 PLCP.  The value       receivedFarEndAlarm means that the DS3 PLCP has       received an incoming Yellow Signal, the value       incomingLOF means that the DS3 PLCP has declared a       loss of frame (LOF) failure condition, and the       value noAlarm means that there are no alarms       present.  See TR-TSV-000773 for a description of       alarm states."    ::= { sipDS3PLCPEntry 3 }sipDS3PLCPUASs OBJECT-TYPE    SYNTAX      Counter32    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "The counter associated with the number of       Unavailable Seconds, as defined by TR-TSV-000773,       encountered by the PLCP."    ::= { sipDS3PLCPEntry 4 }-- The SMDS Applications group-- Applications that have been identified for this group are:--          * IP-over-SMDS (details are specified in RFC 1209)smdsApplications OBJECT IDENTIFIER ::= { sip 4 }ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 }-- Although the objects in this group are read-only, at the-- agent's discretion they may be made read-write so that the-- management station, when appropriately authorized, may-- change the addressing information related to the-- configuration of a logical IP subnetwork implemented on-- top of SMDS.-- This table is necessary to support RFC1209 (IP-over-SMDS)-- and gives information on the Group Addresses and ARP-- Addresses used in the Logical IP subnetwork.-- One SMDS address may be associated with multiple IP-- addresses.  One SNI may be associated with multiple LISs.ipOverSMDSTable OBJECT-TYPE    SYNTAX      SEQUENCE OF IpOverSMDSEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION       "The table of addressing information relevant to       this entity's IP addresses."    ::= { ipOverSMDS 1 }ipOverSMDSEntry OBJECT-TYPE    SYNTAX      IpOverSMDSEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION       "The addressing information for one of this       entity's IP addresses."    INDEX   { ipOverSMDSIndex, ipOverSMDSAddress }    ::= { ipOverSMDSTable 1 }IpOverSMDSEntry ::=    SEQUENCE {       ipOverSMDSIndex       IfIndex,       ipOverSMDSAddress     IpAddress,       ipOverSMDSHA          SMDSAddress,       ipOverSMDSLISGA       SMDSAddress,       ipOverSMDSARPReq      SMDSAddress       }ipOverSMDSIndex OBJECT-TYPE    SYNTAX      IfIndex    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "The value of this object identifies the       interface for which this entry contains management       information. "    ::= { ipOverSMDSEntry 1 }ipOverSMDSAddress OBJECT-TYPE     SYNTAX      IpAddress     MAX-ACCESS  read-only     STATUS      current     DESCRIPTION       "The IP address to which this entry's addressing       information pertains."    ::= { ipOverSMDSEntry 2 }ipOverSMDSHA OBJECT-TYPE    SYNTAX      SMDSAddress    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "The SMDS Individual address of the IP station."    ::= { ipOverSMDSEntry 3 }ipOverSMDSLISGA OBJECT-TYPE    SYNTAX      SMDSAddress    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "The SMDS Group Address that has been configured       to identify the SMDS Subscriber-Network Interfaces       (SNIs) of all members of the Logical IP Subnetwork       (LIS) connected to the network supporting SMDS."    ::= { ipOverSMDSEntry 4 }ipOverSMDSARPReq OBJECT-TYPE    SYNTAX      SMDSAddress    MAX-ACCESS  read-only    STATUS      current    DESCRIPTION       "The SMDS address (individual or group) to which       ARP Requests are to be sent."    ::= { ipOverSMDSEntry 5 }-- The SMDS Carrier Selection group-- This group is used as a place holder-- for carrier selection objects.smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5 }-- The SIP Error LogsipErrorLog OBJECT IDENTIFIER ::= { sip 6 }sipL3PDUErrorTable OBJECT-TYPE    SYNTAX      SEQUENCE OF SipL3PDUErrorEntry    MAX-ACCESS  not-accessible    STATUS      current    DESCRIPTION       "A table that contains the latest occurrence of       the following syntactical SIP L3PDU errors:       - Destination Address Field Format Error,       The following pertains to the 60 least significant       bits of the 64 bit address field.  The 60 bits       contained in the address subfield can be used to       represent addresses up to 15 decimal digits.  Each       decimal digit shall be encoded into four bits       using Binary Coded Decimal (BCD), with the most       significant digit occurring left-most.  If not all       15 digits are required, then the remainder of this       field shall be padded on the right with bits set       to one.  An error is considered to have occurred:       a).  if the first four bits of the address       subfield are not BCD, OR b).  if the first four       bits of the address subfield are populated with       the country code value 0001, AND the 40 bits which       follow are not Binary Coded Decimal (BCD) encoded       values of the 10 digit addresses, OR the remaining       16 least significant bits are not populated with       1's, OR c).  if the address subfield is not       correct according to another numbering plan which       is dependent upon the carrier assigning the       numbers and offering SMDS.       - Source Address Field Format Error,       The description of this parameter is the same as       the description of the Destination Address Field       Format Error.       - Invalid BAsize Field Value,       An error is considered to have occurred when the       BAsize field of an SIP L3PDU contains a value less       that 32, greater than 9220 octets without the       CRC32 field present, greater than 9224 octets with       the CRC32 field present, or not equal to a       multiple of 4 octets,       - Invalid Header Extension Length Field Value,       An error is considered to have occurred when the       Header Extension Length field value is not equal       3.       - Invalid Header Extension - Element Length,       An error is considered to have occurred when the       Header Extension - Element Length is greater than       12.       - Invalid Header Extension - Version Element       Position, Length, or Value,       An error is considered to have occurred when a

⌨️ 快捷键说明

复制代码 Ctrl + C
搜索代码 Ctrl + F
全屏模式 F11
切换主题 Ctrl + Shift + D
显示快捷键 ?
增大字号 Ctrl + =
减小字号 Ctrl + -